A comparison study of the effects of handpiece speed on teeth in debonding procedure

탈접착 후처치시 핸드피스(handpiece) 속도가 치아에 미치는 영향에 대한 비교 연구

  • Park, Soo-Byung (Department of Orthodontics, College of Dentistry, Pusan National University) ;
  • Kim, Gu-Ho (Private practice(Medical Dntal Clinic)) ;
  • Ha, Man-Hee (Department of Orthodontics, College of Dentistry, Pusan National University)
  • 박수병 (부산대학교 치과대학 교정학교실) ;
  • 김구호 (메디칼 치과의원(부산)) ;
  • 하만희 (부산대학교 치과대학 교정학교실)
  • Published : 2004.02.01

Abstract

This study was performed to examine treatment efficiency and patient discomfort rate according to used handpiece speed in clean-up technique. Brackets were bonded to extracted human premolar(50 teeth). After debonding, 50 extracted human premolar were divided Into each two groups(low speed handpiece group with tungsten carbide bur and high speed handpiece group with ultra-fine diamond finishing bur) of 25 according to used handpiece speed in clean-up technique. In clean-up procedure, teeth vibration and pulp thermal changes were measured. After clean-up procedure, the enamel surfaces of randomly selected 10 teeth from each two groups were taken by SEM and evaluated. The findings of this study were as follows ; 1. During resin removal, tooth vibrations of various amplitude in low speed handpiece group were more than those of high speed handpiece. 2. The pulpal thermal changes of high speed handpiece group were significantly higher than those of low speed handpiece group, also the resin removal time in high speed handpiece group was almost as twice as in low speed handpiece group. 3. The figures of SEM to enamel surfaces after resin removal showed that notches and resin remnants in high speed handpiece group were more than those in low speed handpiece group.

본 연구는 탈접착 후처치시 사용된 핸드피스(handpiece)속도에 따른 처치 효율성과 환자 불편감 정도를 알아보기 위하여 시행되었다. 발거된 소구치(50개)에 브라켓을 접착하고 제거한 후 tungsten carbide bur를 장착한 저속 핸드피스와 ultra-fine diamond finishing bur를 장착한 고속 핸드피스로 각각 25개씩 탈접착 후처치를 시행했으며, 이때 각 실험군내 치아의 진동정도와 치수강내 온도 변화를 측정하였다. 이후 각 실험군(저속, 고속 핸드피스군)에서 임으로 10개씩의 치아를 선택하여 주사전자현미경으로 법랑질 표면에 대한 평가를 시행하여, 다음과 같은 결론을 얻었다. 1. 저속 핸드피스를 사용한 레진 제거시 다양한 진폭의 치아 진동이 고속 핸드피스를 이용한 경우보다 많이 나타났다. 2. 고속 핸드피스를 이용한 경우의 치수강내 온도변화가 저속 핸드피스를 사용한 경우보다 유의성 있게 높았으며, 레진 제거 시간 역시 두 배정도 길게 걸렸다. 3. 레진 제거 후 법랑질 표면에 대한 주사전자현미경상은 고속 핸드피스를 사용한 경우에서 절흔들(notches)과 잔여레진들이 저속 핸드피스를 사용한 경우보다 많은 것을 보여주었다.

Keywords

References

  1. Buonocore MG. A simple method of increasing the adhesion of acrylic filling material to enamel surfaces. J Dent Res 1955 : 34 : 849-53
  2. Newman GV. Epoxy adhesives for orthodontic attachments : Progress report Clinical application. Am J Orthod 1965 : 51 : 901-12 https://doi.org/10.1016/0002-9416(65)90203-4
  3. Bennett CG, Shen C, Waldron JM. The effects of debonding on the enamel surface. J Clin Orthod 1984 : 18 : 330-4
  4. Gwinnett AJ, Gorelick L. Microscopic evaluation of enamel after debon-ding : clinical application Am J Orthod 1977 : 71 : 651-665 https://doi.org/10.1016/0002-9416(77)90281-0
  5. Retief DH, Denys FR. Finishing of enamel surfaces after debonding of orthodontic attachments. Angle Orthod 1979 : 49 : 1-10
  6. Zachrisson BU, Arthun J. Enamel surface appearance after various debonding techniques. Am J Orthod 1979 : 75 : 121-7
  7. Rouleau BD Jr, Marshall GW Jr, Cooley RO. Enamel surface evaluations after clinical treatment and removal of orthodontic brackets. Am J Orthod 1982 : 81 : 423-6
  8. 염정배, 이병태. Debonding에 의한 법랑질 crack의 증가. 대치교정지 1987 : 17 : 85-91
  9. Campbell PM. Enamel surfaces after orthodontic bracket debonding. Angle Orthod 1995 : 65 : 103-10
  10. Sturdevant CM, Roberson TM, Heymann HO, Sturdevant JR. The art and science of operative dentistry. St Louis: CV Mosby, 1995 : 339-44
  11. 이종흔, 김중수. 구강생리학. 군자출판사, 1993 : 10-12
  12. 송정국, 손병화. 수종의 bracket(DBS)제거방법에 따른 법랑질 표면에 대한 주사전자현미경적 연구. 대치교정지 1985 : 15 : 271-5
  13. Pus MD, WayDC. Enamel loss due to orthodontic bonding with filled and unfilled resins using various clean-up techniques. Am J Orthod 1980 : 77 : 269-83
  14. Caspersen I. Residual acrylic adhesive after removal of plastic ortho-dontic brackets: A scanning electron microscopic study. Am J Orthod 1977 : 71 : 637-49
  15. Gwinnett AJ, Ceen RF. An ultraviolet photographic technique for monitoring plaque direct bonding procedures. Am J Orthod 1978 : 73 : 178-86
  16. Silverstone LM. Susceptibility to dissolution of fissure-sealed enamel surface artificially abraded in vitro. J Dent Res 1973 : 52 : 967-8
  17. Silverstone LM. The susceptibility to dissolution of acid etched and subsequently abraded enamel in vitro. Caries Research 1977 : 11 : 46-51
  18. Weitman RT, Eames WB. Plaque accumulation on composite surface after various finishing procedures. J Am Dent Assoc 1975 : 91 : 101-6
  19. Lee SH, Chang Yl. Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires. Am J Orthod Dentofacial Orthop 2001 : 120 : 654-63