• Title/Summary/Keyword: 자연치

Search Result 856, Processing Time 0.029 seconds

Autogenous Transplantation of Third Molar to Replace Hopeless Tooth (예후 불량한 치아를 대체하는 제3대구치를 이용한 자가치아이식술)

  • Song, Il-Seok
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.13-24
    • /
    • 2020
  • Autotransplantation is the surgical repositioning of an autogenous erupted or unerupted tooth from one site to another in the same individual. This treatment is indicated in traumatic tooth loss, teeth with severe caries, congenitally missing teeth, teeth with bad prognosis and in case of developmental anomalies of teeth. The following 2 cases describe the potential to utilize autotransplantation to replace hopeless teeth with sound wisdom teeth.

Subjective Symptoms of Peri-Implantitis and Satisfaction according to Prosthesis Methods (임플란트 보철방식에 따른 임플란트 주위염 자각증상 및 만족도)

  • Cha, Ji-Ae;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.175-182
    • /
    • 2017
  • From March 1, 2016 to August 31, 2016, 375 dental implant patients between the ages of 30 and 70 years to evaluate their subjective symptoms and satisfaction according to prosthesis methods. The collected data were analyzed using the chi-square distribution test, t-test, one-way analysis of variance, and multiple logistic regression. Of the patients with subjective symptoms of peri-implantitis, 40.5% reported food impaction, 49.1% reported bleeding, 61.1% reported pain, 61.9% reported halitosis, and the overall satisfaction level with the implants was 3.95 points. In the prosthesis methods, implant-teeth connective group showed the lowest level of the food impaction (21.3%), the pain (35.5%), and the halitosis (36.6%) (p<0.001), and the lowest bleeding was the implant single (33.8%) (p<0.05). Patient satisfaction was higher in the implant-teeth connective group (4.06 points) and the group without bone grafting (4.03 points) (p<0.01). Factor analysis showed that implant satisfaction was 0.43 times lower in the single implant group and 0.44 times lower in the implant-implant connective group than in the implant-teeth connective group. As a result of the study, it is expected that the method of extending the life of adjacent teeth and restoring the function of the tooth defect region is an implant-teeth connection method, so that it can be utilized positively through various clinical studies.

Complications of implants confronting the extruded posterior teeth (정출된 구치와 대합되는 임플란트의 합병증)

  • Jung, Yeon-Wook;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.232-241
    • /
    • 2020
  • Purpose: This study investigated the complications and patterns of implants that confronted with the extruded natural teeth. Materials and Methods: Among patients who received implant treatment between 2006 and 2018 at Chosun University Dental Hospital, only implants that had a maintenance period of at least 5 years and that both implants and confronting natural teeth could be measured and compared on a radiograph were selected. They were divided into two groups. Group 1, experimental group consisted of Implants confronting the extruded natural posterior teeth (n = 167: maxilla (Group 1max) = 92, mandible (Group 1man) = 75) and Group 2, control group consisted of Implants confronting the normal natural posterior teeth (n = 656: maxilla (Group 2max) = 272, mandible (Group 2man) = 384). Results: The incidence of complications between Group 1 and Group 2 was statistically significant. In particular, there was a statistically significant difference between the frequency of marginal bone loss and the amount of marginal bone loss. Conclusion: The extruded natural tooth may cause more frequent complications including bone resorption in the opposing implant.

Interproximal contact loss between implant-supported prostheses: a clinical report (임플란트 고정성 보철물 사이에서의 인접면 접촉상실: 증례보고)

  • Yeon-Hee Park;Kyoung-A Kim;Jung-Jin Lee;Jae-Min Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.47-53
    • /
    • 2024
  • Interproximal contact loss (ICL) is the most frequent complication in partially edentulous patients treated with implant-supported prostheses. However, in most cases, ICL occurs between the implant prosthesis and the natural tooth due to the movement of the natural tooth. There are several causes of ICL that occur between an implant prosthesis and a natural tooth. There are only a few reported cases of ICL occurring between implant prostheses, and explaining the causes of ICL between implant prostheses and natural teeth is challenging. This clinical report describes cases of ICL between implant prostheses and discusses its causes and countermeasures.

Evaluation of interdental distance of natural teeth with cone-beam computerized tomography (콘빔형 전산화단층영상을 이용한 자연치 치간거리의 평가)

  • Oh, Sang-Chun;Kong, Hyun-Jun;Lee, Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.278-283
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the interdental distances of anterior, premolar, and molar teeth at the cementoenamel junction (CEJ) and 2 mm below the CEJ in healthy natural dentition with cone-beam computerized tomography (cone-beam CT) in order to provide valuable data for ideal implant positioning relative to mesiodistal bone dimensions. Materials and Methods: Two hundred patients who visited Dental Hospital, Wonkwang University, who had natural dentition with healthy interdental papillae, and who underwent cone-beam CT were selected. The cone-beam CT images were converted to digital imaging and communication in medicine (DICOM) files and reconstructed in three-dimensional images. To standardize the cone-beam CT images, head reorientation was performed. All of the measurements were determined on the reconstructed panoramic images by three professionally trained dentists. Results: At the CEJ, the mean maxillary interdental distances were 1.84 mm (anterior teeth), 2.07 mm (premolar), and 2.08 mm (molar), and the mean mandibular interproximal distances were 1.55 mm (anterior teeth), 2.20 mm (premolar), and 2.36 mm (molar). At 2mm below the CEJ, the mean maxillary interdental distances were 2.19 mm (anterior teeth), 2.51 mm (premolar), and 2.60 mm (molar), and the mean mandibular interproximal distances were 1.86 mm (anterior teeth), 2.53 mm (premolar), and 3.01 mm (molar). Conclusion: The interdental distances in the natural dentition were larger at the posterior teeth than at the anterior teeth and also at 2 mm below the CEJ level compared with at the CEJ level. The distances between mandibular incisors were the narrowest and the distances between mandibular molars were the widest in the entire dentition.

Investigation on Mechanical Properties of Flax/Vinyl Ester Natural Fiber Composite (아마/비닐 에스테르 자연 섬유 복합재료의 기계적 특성 분석 연구)

  • Park, Hyunbum;Kong, Changduk;Lee, Jeonghwan;Kim, Ingwon;Lee, Hoyeon
    • Composites Research
    • /
    • v.27 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • In this study, an investigation on mechanical properties of flax/vinyl ester natural fiber composite was performed as a precedent study on the design of eco-friendly structure using flax/vinyl ester composite. Vacuum Assisted Resin Transfer Molding(VARTM) manufacturing method was adopted for manufacturing the flax fiber composite specimen. The mechanical properties of the manufactured flax composites were compared with flax composite data cited from some references. Based on this, the experimental data showed that the flax/vinyl ester composite has some advantages when it is applied to environment-friendly structure.

A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case (실패한 이중관 국소의치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Park, Jong-Hoon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.

An Application of the Multigrid Method to Eigenvalue problems (복합마디방법의 고유치문제에 응용)

  • Lee, Gyou-Bong;Kim, Sung-Soo;Sung, Soo-Hak
    • The Journal of Natural Sciences
    • /
    • v.8 no.2
    • /
    • pp.9-11
    • /
    • 1996
  • We apply a full mutigrid scheme to computing eigenvalues of the Laplace eigenvalue problem with Dirichlet boundary condition. We use finite difference method to get an algebraic equation and apply inverse power method to estimating the smallest eigenvalue. Our result shows that combined method of inverse power method and full multigrid scheme is very effective in calculating eigenvalue of the eigenvalue problem.

  • PDF