• 제목/요약/키워드: 입자(particulate)

검색결과 862건 처리시간 0.027초

The Effect of Floating Wetland on Water Quality Improvement in a Eutrophic Lake (부유습지를 이용한 부영양수계 현장 수질개선 효과)

  • Park, Chae-Hong;Park, Myung-Hwan;Choi, Dong-Ho;Choi, Hyung-Joo;Lee, Joon-Heon;Lee, Myung-Hoon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • 제46권1호
    • /
    • pp.116-127
    • /
    • 2013
  • At weekly intervals, we monitored continuous changes in water quality by constructed floating wetland equipped with the four different filter media (sponge, volcanic stone, activated carbon and magnesium hydroxide) in a eutrophic lake from March 2011 to May 2012. We also investigated phyto- and zooplankton communities both in the influent and the effluent water through the floating wetland. Over a 10-month time period, average turbidity (66%), suspended solids (79%) and chlorophyll-a (80%) concentrations were remarkably reduced in the effluent water compared to the influent (P<0.001). The average removal rates of $NO_2-N$ and $NH_3-N$ were 24% and 20%, respectively (P<0.05). The average removal rates of $NO_3-N$ and TN were less than 10% (P>0.05). On the other hand, the average removal rates of $PO_4-P$ and TP were more than 65% (P<0.01). Interestingly, the abundance of phytoplankton in the effluent was decreased about 2.6 times compared to that of the influent, whereas the abundance of zooplankton in the effluent was increased about 3.5 times compared to that of the influent. Overall, particulate matters (SS, Chl-a and TP) and dissolved nutrients ($NO_2-N$, $NH_3-N$ and $PO_4-P$) were particularly reduced at high rates. Therefore, application of our constructed floating wetland in a eutrophic lake improved the water quality and demonstrated a potential for algal bloom mitigation.

A Model for Evaluating the Radioactive Contamination in the Urban Environment (도시환경에서 방사성물질의 오염평가 모델개발)

  • Hwang, Won-Tae;Kim, Eun-Han;Jeong, Hyo-Joon;Suh, Kyung-Suk;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • 제30권3호
    • /
    • pp.99-105
    • /
    • 2005
  • A model for evaluating radioactive contamination in the urban environment, named METRO-K, was developed as a basic step for accident consequence analysis in case of an accidental release. The three kind of radionuclides $(^{137}Cs,\;^{106}Ru,\;^{131}I)$ and the different chemical forms of iodine (particulate, organic and elemental forms) are considered in the model. The radioactive concentrations are evaluated for the five types of surface (roof, paved road, wall, lawn/soil, tree) as a function of time. Using the model, the contaminative impacts of the surfaces were intensively investigated with respect to with and without precipitation during the measurement periods of radionuclides in air. In addition, a practical application study was conducted using $^{137}Cs$ concentration in air and precipitation measured in an European country at the Chernobyl accident. As a result precipitation was an influential factor in surface contamination. The degree of contamination was strongly dependent on the types of radionuclide and surface. Precipitation was more influential in contamination of $^{137}Cs$ than that of $^{131}I$ (elemental form).

Numerical Simulation of PFOA in Tokyo Bay using EMT-3D (EMT-3D 모델을 이용한 동경만의 PFOA 시뮬레이션)

  • Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제13권3호
    • /
    • pp.173-181
    • /
    • 2007
  • A three-dimensional ecological model (EMT-3D) was applied to Tokyo Bay for the simulation of PFOA. EMT-3D was calibrated with seawater analysis data obtained from the study area in 2004. The simulated results of dissolved PFOA were in good agreement with the observed values, with a correlation coefficient(R) of 0.7115${\sim}$0.8759 and a coefficient of determination $(R^2)$ of 0.5062${\sim}$0.7672. The results of sensitivity analysis showed that partition rate, adsorption rate and settling rate were important factors for PFOA in particulate organic matter. In the case of PFOA in phytoplankton, bioconcentration factor, uptake rate and partition rate were important factors. Therefore, the parameters must be carefully considered in the modeling. In the case of 50% and 80% total loads reduction, concentration of dissolved PFOA was shown to be lower than 20ng/L and 10ng/L, respectively. In the case of reduction of loads from rivers in each prefecture, Tokyo prefecture was found to have the most influence on the change of dissolved PFOA in surface water while Chiba prefecture was found to have the most influnce on the change of dissolved PFOA in bottom water.

  • PDF

Trial Burns of Low-Level Radioactive Wastes the Demonstration-Scale Incineration Plant at KAERI (한국원자력 연구소 실증소각시설에서의 저준위방사성폐기물 시험소각)

  • Yang, Hee-Chul;Kim, In-Tae;Kim, Jeong-Guk;Kim, Joon-Hyung;Seo, Yong-Chil
    • Nuclear Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.767-774
    • /
    • 1995
  • Behavior of radionuclides such $^{60}$ Co, $^{54}$ Mn and $^{137}$ Cs in the incineration Process was Studied by trial burns of simulated wastes with radio-isotope tracers. Behavior of nonvolatiles, $^{60}$ Co and $^{54}$ Mn, was similar to that of particulate matters in the process. Decontamination factors(DFs) for $^{60}$ Co and $^{54}$ Mn were 4.7$\times$10$^{5}$ and 6.2$\times$10$^{5}$ , respectively. Behavior of semivolatile radio-isotope, $^{137}$ Cs, was temperature dependent. DFs for $^{l37}$Cs at In different incineration temperature of 85$0^{\circ}C$ and $700^{\circ}C$ were 2.8$\times$10$^3$ and 2.6$\times$10$^4$, respectively. Trial bums of dry active waste(DAW) transported from nuclear power station(NPS) Kori 3,4 were also performed. DF for gross $\beta$/${\gamma}$ radioactivity in DAW was 1.1$\times$10$^{5}$ . This was a little higher than the estimated value, which was calculated from the tracer test results and nuclides distribution in the DAW. Average emission concentration was 0.019 Bq/N $m^3$, which could meet the maximal permissible concentration(MPC) in stack emission.n.

  • PDF

Economic Design of Activated Sludge System at the Optimum Sludge Concentration (슬러지 농도 최적화에 따른 합리적인 활성슬러지공정 설계방안 연구)

  • Lee, Byung Joon;Choi, Yun Young
    • Journal of Korea Water Resources Association
    • /
    • 제47권5호
    • /
    • pp.483-490
    • /
    • 2014
  • The design procedures for a biological reactor and a secondary settling tank (SST) of an activated sludge system are based on the steady state design method (Ekama et al., 1986; WRC, 1984) and the 1-D flux theory design method (Ekama et al., 1997), respectively. This study combined both of the design procedures, to determine the optimum sludge concentration in the reactor and the best design with the lowest cost. The best design of the reactor volume and the SST diameter at the optimum sludge concentration were specified with varying wastewater and sludge characteristics, temperature, sludge retention time (SRT) and peak flow rate. The effects of the influent wastewater characteristics, such as substrate concentration and unbiodegradable particulate fraction, were found to be considerable, but the effect of unbiodegradable soluble fraction was to be negligible. The effects of sludge settling characteristics, were also significant. SRT, as an operating parameter, was found to be an important factor for determining the optimum sludge concentration. However, the effect of temperature was found to be small. Furthermore, for designing a large scale wastewater treatment plant, the number of reactors or SSTs could be estimated, by dividing the total reactor volume or SST area. The new combined design procedure, proposed in this research, will be able to allow engineers to provide the best design of an activated sludge system with the lowest cost.

Distribution and Migration Characteristics of Explosive Compounds in Soil at Military Shooting Ranges in Gyeonggi Province (경기도 북부지역 군용 사격장 토양에 존재하는 화약물질 분포 및 이동 특성 조사)

  • Bae, Bumhan;Park, Jieun
    • Journal of the Korean GEO-environmental Society
    • /
    • 제15권6호
    • /
    • pp.17-29
    • /
    • 2014
  • A remedial investigation was conducted at five military training ranges in northern Gyeonggi province to collect information necessary for the design of on-site treatment facilities for the abatement of explosive compounds release to the environment. These information includes (i) identification of dominant explosive compounds in each range, (ii) discharge/migration routes, and (iii) contaminant distribution in particle size fraction and settling velocity of the soils. The results of investigation showed that TNT and RDX are the major contaminants but the extent of contamination varied depending on the types of military training practices and topography of the site. RDX was also detected in the subsurface soil and in the nearby stream within the training ranges, suggesting release of contaminants to streams. The median concentrations of explosives in the surface soil were less than 20 mg/kg despite several 'hot spots' in which explosives concentrations often exceeds several hundred mg/kg. The average clay contents in the soil of target area was less than 5 % compared to 12 % in the control, indicating loss of smaller particles by surface runoff during rainfall due to lack of vegetative land cover. Analysis of explosive compounds and particle size distribution showed that the amount of explosive compounds in soil particles smaller than 0.075 mm was less than 10 % of the total. Settling column tests also revealed that the quantity of explosive compounds in the liquid phase of the effluent was greater than that in the solid phase. Therefore, pre-treatment of particulate matter in surface runoff of shooting range with a simple settling basin and subsequent effluent treatment with planted constructed wetlands as polishing stage for explosives in the aqueous phase would provide the shooting ranges with a self-standing, sustainable, green solution.

Removal of Chlorinated Organic Compounds in Flue Gas by Activated Carbon Injection in a Semi-Drying Reactor (반건식 반응기에서의 활성탄 혼합주입에 의한 소각로 배가스중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • 제6권2호
    • /
    • pp.121-127
    • /
    • 2000
  • There are several kinds of hazardous materials in incinerator flue gas, such as particulate matter, acid gas, heavy metal, dioxin, etc. The activated carbon adsorption is considered as one of the methods removing dioxin from flue gas. Without any additional equipment and facilities, the activated carbon was mixed with lime and sprayed in the semi-drying reactor of an incinerator and filtered in the bag filter, and its efficiency of removing hazardous organic material was investigated. 1,2-dichlorobenzene (o-DCB) was used as a precursor material of dioxin and the effects of the activated carbon amount, the operating temperature of the reactor, and the atomizer r.p.m were measured and analyzed. Experimental results showed that the optimum outlet temperature of the reactor was $145^{\circ}C$ considering the performance of the bag filter, and the adsorption performance improved with the increase of the atomizer r.p.m. Also the performance of removing o-DCB in the bag filter is higher than of the semi-drying reactor.

  • PDF

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제32권2호
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

A Study on the Effect of Magnetic Field in Electrostatic Precipitator for Improving Precipitation Efficiency of Particulate Matter (미세먼지의 집진효율 향상을 위한 전기집진기의 자계인가특성에 대한 연구)

  • Park, Jae-Youn;Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제22권12호
    • /
    • pp.122-129
    • /
    • 2008
  • This paper gives the experimental results for the effective precipitation of particulated matter(PM) below 1[${\mu}m$] of diameter using the electrostatic precipitator, which is designed by ourselves. In order to improve the precipitation efficiency, the vertical and parallel magnetic field to the electric field is applied simultaneously by arranging ferrite magnets. When the parallel magnetic field is applied, the precipitation efficiency does not improve in comparison with non-magnets. However, when the vertical magnetic field is applied, it is improved about 5[%] more than the case of non-magnetized ferrite plate used. In addition, when the magnets are installed at the center of ground plate electrodes, the precipitation efficiency is ranged from 17 to 32[%] under the applied voltage of 5[kV]. It is similar to the case of the magnet arrangement at the front part of ground electrode. Also, the precipitation efficiency is more improved by arranging magnets as the inside part and zigzag on the electrodes. Especially, large particles of 0.7 and 1[${\mu}m$] is more easily captured by electrostatic precipitator. Consequently, it is convinced that the vertical magnetic field is more desirable than parallel magnetic field on the electric field for the effective treatment of particulated matter.

Effects of Pre-Oxidation for Recirculation of Aquaculture Wastewater (양어용수 재이용을 위한 전 산화처리의 효과)

  • Lim, Jae-Lim;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제22권1호
    • /
    • pp.103-111
    • /
    • 2000
  • Ozonation and advanced oxidation($H_2O_2/O_3$) process were investigated under various experimental conditions to improve the efficiency of biological filter used for the treatment of recycled wastewater from aquaculture. Ammonia removal followed the first-order reaction whose reaction rate constant(k) was $2.0{\times}10^{-2}min^{-1}$ in ozonation. The ammonia removal rate increased according as the bicarbonate alkalinity is increased. About 46% $NH_3$ was oxidized by ozone at 200 mg/L as $CaCO_3$. When alkalinity existed in wastewater, ammonia removal rate by advanced oxidation was very low due to the inhibition effect of bicarbonate. However, when initial pH was adjusted to about 8.2 by 0.1 N KOH, ammonia removal rate was improved higher than that by ozonation. Especially. ammonia removal rate was the highest at $H_2O_2/O_3$ of 0.25 and about 90% of ammonia was removed in 30 min at this ratio as pH was maintained over 9. In the case of wastewater containing ammonia and organic constituents, ammonia removal efficiency by both ozonation and advanced oxidation decreased seriously because organic constituents consumed the oxidant faster than ammonia. In addition the optimal $H_2O_2/O_3$ ratio was changed. Like ammonia removal, DOC(dissolved organic carbon) increased for first 10 min and then decreased slowly because the particulate organic constituents were oxidized rapidly and then produce DOC. Even when the ammonia concentration by twice, oxidation of DOC was not retarded.

  • PDF