Removal of Chlorinated Organic Compounds in Flue Gas by Activated Carbon Injection in a Semi-Drying Reactor

반건식 반응기에서의 활성탄 혼합주입에 의한 소각로 배가스중의 유기 염소계 화합물의 제거 공정 연구

  • 주창업 (한성대학교 안전기술연구소) ;
  • 황재동 (삼성엔지니어링 기술연구소) ;
  • 이조영 (삼성엔지니어링 기술연구소) ;
  • 조철훈 (삼성엔지니어링 기술연구소) ;
  • 신병철 (삼성엔지니어링 기술연구소)
  • Published : 2000.12.01

Abstract

There are several kinds of hazardous materials in incinerator flue gas, such as particulate matter, acid gas, heavy metal, dioxin, etc. The activated carbon adsorption is considered as one of the methods removing dioxin from flue gas. Without any additional equipment and facilities, the activated carbon was mixed with lime and sprayed in the semi-drying reactor of an incinerator and filtered in the bag filter, and its efficiency of removing hazardous organic material was investigated. 1,2-dichlorobenzene (o-DCB) was used as a precursor material of dioxin and the effects of the activated carbon amount, the operating temperature of the reactor, and the atomizer r.p.m were measured and analyzed. Experimental results showed that the optimum outlet temperature of the reactor was $145^{\circ}C$ considering the performance of the bag filter, and the adsorption performance improved with the increase of the atomizer r.p.m. Also the performance of removing o-DCB in the bag filter is higher than of the semi-drying reactor.

소각로 배가스중에는 분진, 산성가스, 중금속, 다이옥신 등의 여러 유해물질이 함유되어 있다. 이러한 유해가스 중의 다이옥신을 제거하기 위한 방법중의 하나인 활성탄의 흡착을 이용한 유해물질 제거 방법의 효율을 조사하였다. 다이옥신의 전구물질인 1,2-dichlorobenzene (o-DCB)를 사용하였으며 기존의 소각로에 추가 설비가 필요 없이 활성탄을 반건식 반응기에서 소석회와 함께 분무하고 백필터로 여과하는 공정에 대하여 반응기 운전 온도, atomizer r.p.m., 활성탄 양 변화에 대한 효율을 조사하였다. 실험결과 소석회와 활성탄 분무를 위한 atomizer의 rpm이 클수록, 즉 분무 입자 크기가 작을수록 제거 효율은 증가하였고 반건식 반응기에서의 배가스 유출온도는 백 필터의 유입온도에 준하여 결정하는 것이 타당하며 $145^{\circ}C$로 유지하는 것이 필요하였다. 또한 백필터에서의 제거효율이 반건식 반응기에서의 제거효율보다 높음을 알 수 있었다.

Keywords