• Title/Summary/Keyword: 인공 고관절 치환술

Search Result 15, Processing Time 0.025 seconds

The Problem-Solving Approach for Improving Walking Ability in Patient with Total Hip Replacement: Applied ICF Tool for Case Study (고관절 인공관절 치환술 환자의 보행능력 증진을 위한 문제해결 접근: ICF Tool을 적용한 단일사례연구)

  • Song, Hyun-seung;Kim, Suhn-yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.63-71
    • /
    • 2015
  • Background: The purpose of the study, using the ICF Tool in the process of rehabilitation of artificial joint replacement surgery of the hip joint, goal setting and understanding of the problem, through the process of creating intervention strategies, useful clinical practical course for rehabilitation I try to present the data. Methods: Fracture was the left total hip replacement (THR) surgery due to women of 76 years old. I proceed in order screening, evaluation, diagnosis, prognosis, treatment planning and intervention, re-screening. Needs of the patient was walking short distances for using the toilet. In order to improve was carried out arbitration, after you have created a list of issues that limit the ability to walk short distances. Results: It was revealed improved results in self-paced walk test (SPWT) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was used to examine whether the goals. In addition, MMT VAS, DGI, and TUG is a detailed goal was improved. Conclusions: It can be shown objectively the results of interventions performed for the purpose of solving the problem which is grasped through clinical Practical course for short-range walking ability enhance patient THR. I considered practical clinical course using the ICF Tool would be useful.

  • PDF

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

Surgical Complications in Heart Transplant Recipients - A Single Center Experience - (심장이식후에 발생한 외과적 합병증 - 단일 센터 경험 -)

  • Park, Kook-Yang;Park, Chul-Hyun;Jeon, Yang-Bin;Choi, Chang-Hyu;Lee, Jae-Ik
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.719-724
    • /
    • 2009
  • Background: As the patients who undergo heart transplantation have achieved better survival in recent years, growing number of recipients are at a risk for experiencing surgical complications in addition to rejection and infection. In this paper, we report on our experience with the surgical complications that occurred in heart transplant recipients. Material and Method: From April 1994 to September 2003, 37 heart transplantations were performed at our center by a single surgeon. The indications for transplantation were dilated cardiomyopathy, ischemic cardiomyopathy, valvular cardiomyopathy and familial hypertrophic cardiomyopathy. Result: Twenty postoperative complications required surgeries in 15 patients (41%). The types of operations required were; redo-sternotomy for bleeding (5), pericardiostomy for effusion (4), implantation of a permanent pacemaker (1), right lower lobe lobectomy for aspergilloma (1), removal of urinary stone (1), cholecystectomy for gall bladder stone (1), drainage of a perianal abscess (1), paranasal sinus drainage (1), total hip replacement (1), partial gingivectomy due to gingival hypertrophy (1), urethrostomy (1), herniated intervertebral disc operation (1) and total hysterectomy for myoma uteri (1). The locations of the complications were mediastinal in 10 (27%) cases and extramediastihalin 10 (27%) cases. Conclusion: The relatively high incidence of extrathoracic complications associated with heart transplantation emphasizes the importance of a multidisciplinary approach to the improve long-term survival when managing those complex patients.

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF