• Title/Summary/Keyword: 이상 수질

Search Result 1,235, Processing Time 0.029 seconds

A Study on the Mineral Water in Europe Partial Area (유럽 일부 지역의 광천수 수질특성에 관한 연구)

  • Hwang Sang-Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.4 s.54
    • /
    • pp.76-81
    • /
    • 2004
  • From September 1, 2003 to November 30, 2004, 20 mineral water wells were selected for some area in east Europe and the study on their water quality was analized. It revealed that mineral water contained considerable quantity of magnesium ions which helps the smooth activities of vascular muscles, nervous systems and protects skins from allergic reactions. It also lowers cholesterol level and contains high concentration of calcium ions which is one of the vital components of teeth and bone like phosphorus. Thus it is concluded that it is not qualified as boiler feed water as it has overall high degree of hardness by the presence of four times content of $Mg^{2+}\;and\;Ca^{2+}$.

Comparison of machine learning algorithms for Chl-a prediction in the middle of Nakdong River (focusing on water quality and quantity factors) (머신러닝 기법을 활용한 낙동강 중류 지역의 Chl-a 예측 알고리즘 비교 연구(수질인자 및 수량 중심으로))

  • Lee, Sang-Min;Park, Kyeong-Deok;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.277-288
    • /
    • 2020
  • In this study, we performed algorithms to predict algae of Chlorophyll-a (Chl-a). Water quality and quantity data of the middle Nakdong River area were used. At first, the correlation analysis between Chl-a and water quality and quantity data was studied. We extracted ten factors of high importance for water quality and quantity data about the two weirs. Algorithms predicted how ten factors affected Chl-a occurrence. We performed algorithms about decision tree, random forest, elastic net, gradient boosting with Python. The root mean square error (RMSE) value was used to evaluate excellent algorithms. The gradient boosting showed 10.55 of RMSE value for the Gangjeonggoryeong (GG) site and 11.43 of RMSE value for the Dalsung (DS) site. The gradient boosting algorithm showed excellent results for GG and DS sites. Prediction value for the four algorithms was also evaluated through the Receiver operating characteristic (ROC) curve and Area under curve (AUC). As a result of the evaluation, the AUC value was 0.877 at GG site and the AUC value was 0.951 at DS site. So the algorithm's ability to interpret seemed to be excellent.

The Characteristics of the Ozonizer with Cascade-Type Plate Electrode (Cascade형 평판전극 오존발생기의 특성)

  • Yoon, Dae-Hee;Song, Hyun-Jig;Lee, Sang-Keun;Park, Kwang-Seo;Kim, Jong-Hyun;Park, Won-Zoo;Lee, Kwong-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.80-87
    • /
    • 2009
  • Recently, ozone has been utilized in various fields thanks to its effectiveness, and has been in ever-growing demand. Accordingly, various kinds of ozonizers have been examined among researchers. This paper is concerned with developing the cascade-type plate electrode ozonizer(PTO) for improvements of indoor air, water supply and drainage and investigating its characteristics. Four types of ozonizers have been devised according to their size, numbers and arrangement Electric discharge area of each type of ozonizer has the same size of 22,400[$mm^2$], and its discharge power has the maximum 40[w]. As the result of having studied ozone generation ozone concentration and ozone yield characteristics of each ozonizer, we found that the type of ozonizer in which eight plates were arranged into cascade type(PTO-4) was the most excellent one.

Study on for Estimation of Ecological Instream Requirement in Nakdong River (낙동강권역 생태계 필요유량 산정방법 비교 연구)

  • Park, Jung-Eun;Kim, Jeong-Kon;Jeong, Young-Won;Lee, Sang-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.180-180
    • /
    • 2011
  • 하천의 정상적인 기능 및 상태를 유지하기 위하여 필요한 최소유량을 의미하는 하천유지유량은 하천수질보전, 하천생태계보호, 하천경관보전, 염수침입 방지, 하구막힘 방지, 하천시설물 및 취수원보호, 지하수위 유지 등을 감안하여 산정하게 된다. 하천유량 변화는 하천내 동 식물에 영향을 미치며, 특히 고등 생물인 어류의 서식처, 산란장소 및 산란조건 등은 유량 및 수위변화에 민감하게 반응하므로 하천구간별 어류의 서식처 유지에 적절한 수심, 유속 등 수리 조건을 제공할 수 있는 유량을 산정하게 된다. 국내에서는 90년대 후반부터 생태계를 고려한 하천유지유량 개념이 도입되었으며, 어류의 적절한 수생 서식환경 평가를 위해 주로 유량 점증 방법론(IFIM, Instream Flow Incremental Methodology) 개념에 입각한 물리서식처 모형을 이용한 연구가 진행되어 왔다. 본 연구에서는 낙동강수계 13개 지점을 선정하여 어류상 조사를 실시하여 어류의 물리서식처 모형과 수심-유속-유량 관계곡선을 이용한 간단법을 이용하여 생태계 보전을 위한 필요유량을 산정하였다. 어류 물리서식처 모형으로는 어류서식환경 평가에 가장 광범위하게 이용되고, 생태적 특성을 반영할 수 있는 유량점증방법론의 PHABSIM(Physical HABitat SIMulation) 모형을 선택하였다. 현장 모니터링 및 문헌조사를 통해 각 지점별 대표어종을 선정하고, 유량, 수심, 저수로 하천단면, 하상재료와 같은 수리특성을 조사하고, 선정된 한계단면에 대한 유량측정을 실시하였으며, 수심-유속-유량 관계곡선을 통하여 각 지점의 대표어종이 서식할 수 있는 최소유량을 산정하였다. 또한 지점별로 서식처 적합도 지수(HSI, Habitat Suitability Index)와 가중가용면적(WUA, Weighted Usable Area)를 산정하였으며, 이는 PHABSIM 모형의 적용에 이용되었다. 물리서식처 모형과 간단법 적용결과를 비교해본 결과, 모든 지점에서 물리서식처 모형 적용결과가 간단법에 비해 크게 산정되었는데, 이는 간단법이 성어기 서식에 필요한 최소 수리조건을 선택하였지만, PHABSIM의 경우 성어기 어류서식의 최적 수심 및 유속을 이용하여 가중가용면적을 산정하기 때문인 것으로 판단된다. 어류서식과 관련된 많은 관련 데이터가 축적된다면 어류서식처에 맞는 최적의 생태유량을 보다 정확하게 산정할 수 있을 것으로 판단된다.

  • PDF

Analysis of Air-water Temperature Elasticity Taking into Account the Confidence Interval in Major Tributary of Nakdong River (낙동강 주요 지류의 신뢰구간을 고려한 기온-수온 탄성도 분석)

  • Park, Jaebeom;Kal, Byungseok;Kim, Seongmin
    • Journal of Wetlands Research
    • /
    • v.22 no.3
    • /
    • pp.178-186
    • /
    • 2020
  • In this study, the elasticity was calculated and sensitivity analysis was performed using air-water temperature data of the major tributaries of the Nakdong River. We developed a nonparametric elasticity analysis technique capable of estimating the confidence interval for elasticity and verifying the hypothesis, and examined its applicability compared to the existing method using the median value. It is analyzed that the elasticity of winter is low and the elasticity of summer and autumn is high, so that the fluctuation of water temperature and water quality according to the fluctuation of air temperature is large. The spatial elasticity tends to be low in the Geumho River area, which is influenced by artificial factors such as sewage treatment plant effluent, small and medium-sized livestock wastewater, and small-scale factory wastewater. Since the elasticity of major tributaries of the Nakdong River is over weak and is reasonable at a significance level of 5%, it was analyzed that the air-water temperature fluctuation caused by climate changes is large.

Heavy Metal Contamination in Roadside Sediments within the Watershed of the Hoidong Reservoir in Busan City (부산시 회동저수지 집수분지 내 주요 도로변 퇴적물의 중금속 오염 평가)

  • Youm Seung-Jun;Lee Pyeong-Koo;Yeon Kyu-Hun;Kang Min-Ju
    • Economic and Environmental Geology
    • /
    • v.38 no.3 s.172
    • /
    • pp.247-260
    • /
    • 2005
  • Extractable concentrations (0.1 N & 1.0 N HCI) of heavy metals in roadside sediments are lower than guidelines for soil recommended by Ministry of Environment. Heavy traffic areas (such as No. 7 national road) show high contents of heavy metals, especially, at curved areas, gully pot, crackdown areas on overspeed, pedestrian crossing etc. Fine fractions $(<63\;{\mu}m)$ of roadside sediments have the highest concentrations of heavy metals, but mass loadings of heavy metal are determined by coarse fractions $(>100{\mu}m)$, due to washing out of fine fraction sediment by runoff water. Proper treatment facilities are needed to control the inflow of fine roadside sediments from No. 7 national road and bridge such as Hanmul bridge.

The Effects of Physico-Chemical Factors on the Microbial Population in Groundwater (지하수 세균 군집에 미치는 물리화학적 환경요인의 영향)

  • 안영범;김여원;이대영;민병례;최영길
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.4
    • /
    • pp.215-222
    • /
    • 1998
  • The objective of this study was to investigate the effects of physico-chemical environmental factors on the changes of bacterial population from two sites used for drinking water and eight sites polluted with various pollutant in Seoul city. In all the stations except for two sites used for drinking water, the concentrations of nitrate- nitrogen and ammonia were in excess of the criteria of groundwater quality by the result of analysis of 40 variations including physicochemical environmental factors, heavy metals, and bacterial populations. The numbers of total bacteria, heterotrophic bacteria and functional groups of bacteria were ranged from 5.1 to 41.4${\times}$10$\^$5/cells/ml and from 0.01 to 29.6${\times}$10$^4$cfu/ml, respectively. The activities of extracellular enzymes showed the ranges of 0.005∼11.3${\mu}$M/l/hr and its order to lipase, phophatase, ${\beta}$-glucosidase, cellulase, chitinase, amylase. The results of correspondence and multidimensional scaling analysis between bacterial populations and its physico-chemical environmental factors were explained the effects of physico-chemical environmental factors according to site characters and separated four group, which is accord with potential pollutants at wells.

  • PDF

Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community (농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.267-274
    • /
    • 2016
  • Sewerage supply in rural community is the important for water quality protection of water system such as river, lake and wetland. And characteristic of small scale wastewater system that have wide range of inflow and concentration in sewage should be considered for stable operation of small scale wastewater treatment plant. In this research, characteristics of flow ratio (flow / designed flow), effect on treatment efficiency of small scale wastewater treatment plant and assessment of optimal flow ratio were conducted through analysis on operation result of 18 small scale wastewater treatment plant in Bong-hwa gun. As a result, flow ratio shows the higher value during summer. However pollutants concentration in sewage was shown the higher concentration during autumn and winter. Treatment of small scale wastewater treatment plant is increased when flow ratio increased, and nutrient treatment efficiency is more sensitive to change of flow ratio than organic compound and suspended solids. According to this research result, it need to be maintained flow ratio 0.8 over value for stable treatment efficiency of small scale wastewater treatment plant.

Studies on probability extinction of Peregrine falcon species wintering around Jang Hang wetlands in the Han river (겨울철 한강 장항습지에 서식하는 매 멸종확률 예측에 대한 연구)

  • LEE, Sangdon
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.282-285
    • /
    • 2016
  • Peregrine falcon (Falco peregrinus) are listed as endangered species and Natural monument #323 in Korea, and this study examined the possibility of extinct of peregrine falcon in Jang Hang wetland near Han river using with the application of Population Viability Analysis (PVA) technique. In Jang Hang wetland areas population was monitored during 1999-2005 averaging 10.8 individuals and PVA analysis was done for the 5 years (2015-2020) using the average population size. Using the initial population was estimated 20% of extinct rate during the time. This estimation was quite low considering water pollution and loss of habitat. Also PVA only used population size lacking in other life history information. Nonetheless falcon population can be in risk of extinction if the current construction of crossovers in the river, cement bank are maintained. Long term information regarding life history needs essential.

Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System (개선된 여과형 시설의 비점오염물질 처리효율 평가)

  • Kang, Hee-Man;Choi, Ji-Yon;Kim, Lee-Hyung;Bae, Woo-Keun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • The objective of this study was to evaluate the efficiency of a modified filtration system treating non-point source (NPS) pollutants. The developed Best Management Practice (BMP) technology was designed based on the geographical and climatic characteristics of the site. A lab-scale test experiment was conducted using three different hydraulic loading rates representing the first flush flow, average flow and overflow conditions during a rainfall event. Water quality analysis was performed on the water samples taken at the inflow, outflow and infiltration during the test experiment of the lab-scale BMP. Also, the water and mass balance at different hydraulic loading rates was determined. Results from the lab-scale test experiment showed that the lab-scale BMP had a high removal efficiency of 80-90% for all NPS pollutants. The overflow test condition obtained the lowest removal efficiency among the hydraulic loading rates because it gave less opportunity for the pollutants to be filtered and retained inside system. The infiltration ratio was approximately 1 % of the inflow and outflow. Increasing the infiltration ratio requires technical approach of soil amendment where the BMP is installed.