• Title/Summary/Keyword: 이동영상

Search Result 3,197, Processing Time 0.038 seconds

Biodistribution and Metabolism of I-123 Labelled Fatty Acid(I) : [I-123]15-(p-iodophenyl)pentadecanoic acid(IPPA) (I-123 표지 지방산의 체내 분포 및 대사(I) : [I-123]15-(p-iodophenyl)pentadecanoic acid(IPPA))

  • Chang, Young Soo;Lee, Dong Soo;Jeong, Jae Min;Suh, Yong-Sup;Chung, June-Key;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.50-60
    • /
    • 1998
  • I-123 labelled fatty acids are suitable for investigation of regional myocardial metabolism, so they are on the clinical trial. However, the precise properties of these materials are not characterized yet. We have synthesized phenylpentadecanoic acid and labeled this compound with I-123. The purpose of this study was to examine the stability, biodistribution, metabolism and SPECT imaging of [I-123]15-(p-iodophenyl)pentadecanoic acid(I-123-IPPA) that we made. The stability test of I-123-IPPA in serum of rat, mouse and human showed no free I-123 after 1 hour. In biodistribution study in mice for various time intervals after injection(5, 10, 15, 30, 60 minutes), uptake in myocardium was 14.5%ID/g(5 min), and 1.9%ID/heart(5 min), while uptake in muscles was 2.6%ID/g(5 min). Myocardium to blood ratio and myocardium to lung ratio increased for 5 min after injection and then decreased rapidly. Chromatographic data of rat blood and urine showed that little PPA was found in blood and urine at 15-20 min after injection. The myocardial I-123-IPPA SPECT images of a dog with myocardial infarction showed defects similar to those of Tc-99m-MIBI and F-18-FDG. These data suggest that I-123-IPPA is quite stable in vitro and shows favorable biodistribution in mice. SPECT imaging with I-123-IPPA demonstrated infarct zone as photon defect in dog model of myocardial infarction. I-123-IPPA may be used for the evaluation of fatty acid metabolism in clinical trials in Korea.

  • PDF

Comparison of rCBF between Patients with Medial Temporal Lobe Epilepsy and Normal Controls using ${H_2}^{15}O\;PET$ (내측 측두엽 간질환자와 정상인의 ${H_2}^{15}O\;PET$을 이용한 뇌 혈류량 비교)

  • Kang, Eun-Joo;Lee, Jae-Sung;Nam, Hyun-Woo;Lee, Sang-Kun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.155-165
    • /
    • 2002
  • Purpose: The aim of this study was to identify the brain areas whose regional cerebral blood flow (rCBF) was changed in medial temporal lobe epilepsy (mTLE) using ${H_2}^{15}O-PET$. Materials and Methods: 12 patients with mTLE (6 left, 6 right mTLE) and 6 normal controls were scanned during a fixation baseline period and a sensory-motor condition where subjects pressed a button to an upward arrow. A voxel-based analysis using SPM99 software was peformed to compare the patient groups with the normal controls for the rCBF during fixation baseline period and for relative changes of rCBF during the sensory-motor task relative to fixation. Results: During the fixation baseline, a significant reduction of rCBF was found posterior insula bilaterally and right frontopolar regions in right mTLE patients compared to the normal controls. In left mTLE patients, the reduction was found in left frontopolar and temporal legions. During the sensory-motor task, rCBF increase over the fixation period, was reduced in left frontal and superior temporal legions in the right mTLE patients whereas in various areas of right hemisphere in left mTLE patients, relative to normal controls. However, the increased rCBF was also found in the left inferior parietal and anterior thalamic/fornix regions in both right and left mTLE patients compared to normal controls. Conclusion: Epilepsy induced changes were found not only in relative increase/decrease of rCBF during a simple sensory-motor control condition relative to a fixation rest condition but also in the relative rCBF distribution during the rest period.

3D Facial Animation with Head Motion Estimation and Facial Expression Cloning (얼굴 모션 추정과 표정 복제에 의한 3차원 얼굴 애니메이션)

  • Kwon, Oh-Ryun;Chun, Jun-Chul
    • The KIPS Transactions:PartB
    • /
    • v.14B no.4
    • /
    • pp.311-320
    • /
    • 2007
  • This paper presents vision-based 3D facial expression animation technique and system which provide the robust 3D head pose estimation and real-time facial expression control. Many researches of 3D face animation have been done for the facial expression control itself rather than focusing on 3D head motion tracking. However, the head motion tracking is one of critical issues to be solved for developing realistic facial animation. In this research, we developed an integrated animation system that includes 3D head motion tracking and facial expression control at the same time. The proposed system consists of three major phases: face detection, 3D head motion tracking, and facial expression control. For face detection, with the non-parametric HT skin color model and template matching, we can detect the facial region efficiently from video frame. For 3D head motion tracking, we exploit the cylindrical head model that is projected to the initial head motion template. Given an initial reference template of the face image and the corresponding head motion, the cylindrical head model is created and the foil head motion is traced based on the optical flow method. For the facial expression cloning we utilize the feature-based method, The major facial feature points are detected by the geometry of information of the face with template matching and traced by optical flow. Since the locations of varying feature points are composed of head motion and facial expression information, the animation parameters which describe the variation of the facial features are acquired from geometrically transformed frontal head pose image. Finally, the facial expression cloning is done by two fitting process. The control points of the 3D model are varied applying the animation parameters to the face model, and the non-feature points around the control points are changed by use of Radial Basis Function(RBF). From the experiment, we can prove that the developed vision-based animation system can create realistic facial animation with robust head pose estimation and facial variation from input video image.

Investigation of Measurement Feasibility of Large-size Wastes Based on Unmanned Aerial System (UAS 기반 대형 폐기물 발생량 측정 가능성 모색)

  • Son, Seung Woo;Yu, Jae Jin;Jeon, Hyung Jin;Lim, Seong Ha;Kang, Young Eun;Yoon, Jeong Ho
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.809-820
    • /
    • 2017
  • Efficient management of large-size wastes generated from disasters etc. is always in demand. Large-size wastes are closely connected to the environment, producing adverse effects on the air quality, water quality, living environment and so on. When large-size wastes are generated, we must be able to estimate the generated amount in order to transfer them to a temporary trans-shipment site, or to properly treat them. Currently, we estimate the amount of generated large-size wastes by using satellite images or unit measure for wastes; however, the accuracy of such estimations have been constantly questioned. Therefore, the present study was performed to establish three-dimensional spatial information based on UAS, to measure the amount of waste, and to evaluate the accuracy of the measurement. A measurement was made at a waste site by using UAS, and the X, Y, Z RMSE values of the three-dimensional spatial information were found to be 0.022 m, 0.023 m, and 0.14 m, all of which show relatively high accuracy. The amount of waste measured using these values was computed to be approximately $4,273,400m^3$. In addition, the amount of waste at the same site was measured by using Terrestrial LiDAR, which is used for the precise measurement of geographical features, cultural properties and the like. The resulting value was $4,274,188m^3$, which is not significantly different from the amount of waste computed by using UAS. Thus, the possibility of measuring the amount of waste using UAS was confirmed, and UAS-based measurement is believed to be useful for environmental control with respect to disaster wastes, large-size wastes, and the like.

Evaluation of Endothelium-dependent Myocardial Perfusion Reserve in Healthy Smokers; Cold Pressor Test using $H_2^{15}O\;PET$ (흡연자에서 관상동맥 내피세포 의존성 심근 혈류 예비능: $H_2^{15}O\;PET$ 찬물자극 검사에 의한 평가)

  • Hwang, Kyung-Hoon;Lee, Dong-Soo;Lee, Byeong-Il;Lee, Jae-Sung;Lee, Ho-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Purpose: Much evidence suggests long-term cigarette smoking alters coronary vascular endothelial response. On this study, we applied nonnegative matrix factorization (NMF), an unsupervised learning algorithm, to CO-less $H_2^{15}O-PET$ to investigate coronary endothelial dysfunction caused by smoking noninvasively. Materials and methods: This study enrolled eighteen young male volunteers consisting of 9 smokers $(23.8{\pm}1.1\;yr;\;6.5{\pm}2.5$ pack-years) and 9 nonsmokers $(23.8{\pm}2.9 yr)$. They do not have any cardiovascular risk factor or disease history. Myocardial $H_2^{15}O-PET$ was performed at rest, during cold ($5^{\circ}C$) pressor stimulation and during adenosine infusion. Left ventricular blood pool and myocardium were segmented on dynamic PET data by NMF method. Myocardial blood flow (MBF) was calculated from input and tissue functions by a single compartmental model with correction of partial volume and spillover effects. Results: There were no significant difference in resting MBF between the two groups (Smokers: 1.43 0.41 ml/g/min and non-smokers: $1.37{\pm}0.41$ ml/g/min p=NS). during cold pressor stimulation, MBF in smokers was significantly lower than 4hat in non-smokers ($1.25{\pm}0.34$ ml/g/min vs $1.59{\pm}0.29$ ml/gmin; p=0.019). The difference in the ratio of cold pressor MBF to resting MBF between the two groups was also significant (p=0.024; $90{\pm}24%$ in smokers and $122{\pm}28%$ in non-smokers.). During adenosine infusion, however, hyperemic MBF did not differ significantly between smokers and non-smokers ($5.81{\pm}1.99$ ml/g/min vs $5.11{\pm}1.31$ ml/g/min ; p=NS). Conclusion: in smokers, MBF during cold pressor stimulation was significantly lower compared wi4h nonsmokers, reflecting smoking-Induced endothelial dysfunction. However, there was no significant difference in MBF during adenosine-induced hyperemia between the two groups.

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Difference of Time Course of Functional Recovery after Revascularization According to Preoperative Reversibility of Perfusion Impairment in Ischemic Myocardial Dysfunction (허혈성 심근 기능장애에서 술전 관류결손의 가역성에 따른 재관류 시술 이후 심근 기능회복 양상의 시간적 차이)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Kim, Ki-Bong;Kim, Yu-Kyeong;Yeo, Jeong-Seok;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.364-370
    • /
    • 2001
  • Purpose: In the revascuarization of ischemic dysfunctional myocardium, stunned myocardium was reported to recover function earlier than hibernating myocardium. It was also suggested that stunning and hibernation could be discriminated by reversibility of perfusion impairment on myocardial SPECT. In this study, we investigated the time course of functional recover after CABG according to reversibility of perfusion impairment. Materials and Methods: In 92 patients with coronary artery disease, Tl-201 rest/dipyridamole stress Tc-99m-MIBI gated SPECT was performed before, 3 months after, and 17 months after CABG. Using a 20-segment model, segmental perfusion and systolic thickening were automatically quantified. Perfusion-impaired segments with abnormal thickening were classified by reversibility into reversible (REV) and irreversible (IRREV) groups. The proportions of function-recovered segments were compared between groups and also between 3 months and 17 months in each group. Results: A total of 129 segments were Included In the analysis, and 76 were REV and 53 were IRREV. At 3 months after CABG, 61 segments (80%) in REV group showed functional recovery while 28 segments (53%) in IRREV group did (p<0.001). However, at 17 months after CABG, 60 segments (79%) in REV group and 37 segments (70%) un IRREV group showed functional recovery (p=n.s.). When comparing 3 months and 17 months in each group, REV group showed no difference, while IRREV group showed significant further improvement (p<0.05). Conclusion: In viable myocardium with ischemic myocardial dysfunction, the segments with reversible perfusion impairment recover function earlier after revascularization than irreversible segments.

  • PDF

Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease ($^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향)

  • Lee, Kyung-Han;Lee, Myung-Chul;Lee, Dong-Soo;Kwon, June-Soo;Kim, Jong-Ho;Chung, June-Key;Woo, Jong-In;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.282-292
    • /
    • 1994
  • Brain perfusion SPECT shows typical regional perfusion abnormalities in Alzheimer's disease(AD) and is useful for its diagnosis. However, there is also arguement that these patterns show significant overlap with other causes, and the accuracy for SPECT in differentiating AD has shown conflicting results. We postulate that the variation in re-ported results are partly due to a difference in patient or control selection with special reference to the mixture of ischemic cerebral disease in the studied population. To deter-mine the effect of ischemic lesions and the nature of control subjects on SPECT studies for AD, we performed $^{99m}Tc$-HMPAO single photon emission computed tomography (SPECT) in 11 probable AD patients with a low (<4) Hachinski ischemic score and 12 non-demented age matched controls. Magnetic resonance imaging(MRI) disclosed ischemic cerebral lesions in 27% (3/11) of the PAD group and 25% (3/12) of the control group. Regional perfusion indices were quantitated from the SPECT images as follows and the distribution of perfusion indices from both groups were compared. This was repeated with controls after excluding those with significant ischemic lesions by MRI : regional perfusion index = average regional count/average cerebellar count All PAD patients showed perfusion abnormality in SPECT. However, 53% (10/12) of controls also showed perfusion at-normalities, and no pattern could reliably differentiate the two groups. After excluding controls with significant cerebral ischemia, the difference in temporal and parietal perfusion index was increased. A decreased tempore-parietal and any parietal or temporal per-fusion index had a sensitivity of 18% and 36% in detecting AD, respectively. When using a separate group of normal age mathced controls, the indices showed an even more difference in the temporal and parietal lobes and the sensitivity of a decreased tempore-parietal and any parietal or temporal perfusion index had a sensitivity of 36% and 55% in detecting AD, respectively. Thus, the type of control with special reference to the pres-once of ischemic cerebral lesions contribute significantly to the accuracy of perfusion SPECT in diagnosing AD. This nay have particular importance in the diagnosis of AD in populations where the prevalance of cerebrovascular disease is high.

  • PDF

A Convenient Radiolabeling of [$^{11}$C](R)-PK11195 Using Loop Method in Automatic Synthesis Module ($^{11}$C 표지 자동합성장치에서 루프법을 이용한 ($^{11}$C)(R)-PK11195의 간편한 합성법)

  • Lee, Hak-Jeong;Jeong, Jae-Min;Lee, Yun-Sang;Kim, Hyung-Woo;Choi, Jae-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.337-343
    • /
    • 2009
  • Purpose: ((R)-1-(2-chlorophenyl)-N-1-[$^{11}$C]methyl-N(1-propyl)-3-isoquinoline carboxamide ((R)-PK11195) is a specific ligand for the peripheral type benzodiazepine receptor and a marker of activated microglia, used to measure inflammation in neurologic disorders. We report here that a direct and simple radiosynthesis of [$^{11}$C](R)-PK11195 in mild condition using NaH suspension in DMF and one-step loop method. Materials and Methods: (R)-N-Desmethyl-PK11195 (1 mg) in DMSO (0.1 mL) and NaH suspension in DMF (0.1 mL) were injected into a semi-prep HPLC loop. [$^{11}$C]methyl iodide was passed through HPLC loop at room temperature. Purification was performed using semi-preparative HPLC. Aliquots eluted at 11.3 min were collected and analyzed by analytical HPLC and mass spectrometer. Results: The labeling efficiency of [$^{11}$C](R)-PK11195 was 71.8$\pm$8.5%. The specific activity was 11.8:$\pm$6.4 GBq/$\mu$mol and radiochemical purity was higher than 99.2%. The mass spectrum of the product eluted at 11.3 min showed m/z peaks at 353.1 (M+1), indicating the mass and structure of (R)-PK11195. Conclusion: By the one-step loop method with the [$^{11}$C]CH3l automated synthesis module, [$^{11}C$](R)-PK11195 could be easily prepared in high radiochemical yield using NaH suspension in DMF.

Preparation and Properties of the X-ray Storage Phosphors BaFBr1-xIx:Eu2+, Na+ (X-선 저장 BaFBr1-xIx:Eu2+, Na+ 형광체의 제조 및 특성)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, Chan-Jung;Kim, Wan;Kang, Hee-Dong;Kim, Do-Sung;Seo, Hyo-Jin;Doh, Sih-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2002
  • The forming conditions of X-ray storage phosrhors $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ have been investigated, and measured the PSL emission spectra and its intensity, fading characteristics and does dependence of the prepared phosphors. These characteristics were compared with those of commercial image plate (ST-III) obtained from Fuji Photo Film Co. The optimal preparing conditions of $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ Phosphor were 0.5 mol% of $EuF_3$, 4.0 mol% of NaF and composition ratio x=0.3, and the sintering temperature were $950^{\circ}C$ in $H_2$ atmosphere. When the composition ratio x was equal to 0, the spectral range of the luminescence of $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ phosphor was $365{\sim}420\;nm$, and its maximum luminescence intensity appeared at 390 nm. When composition ratio x was not equal to 0, the wavelength ranges and peak of the spectra were shifted to the longer wavelength with the growth of composition ratio x. A good linearity was shown between the PSL intensity and X-ray irradiation dose. The phosphor sample with x=0.3 exhibited better fading characteristics than that of other $BaFBr_{1-x}I_x:Eu^{2+}$ phosphor samples, and the fading characteristics of the PSL intensity at room temperature were shown poorer with increasing $I^-$ ion concentration. The lattice constant of the phosphor becomes larger with increasing the $I^-$ ion concentration.