• Title/Summary/Keyword: 유.누출

Search Result 68, Processing Time 0.027 seconds

A Note on in-Situ Burning of Marine Oil Spills (해상누유 현장소각 기술에 대한 소고)

  • Sung H.G.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.58-65
    • /
    • 2000
  • Responses to marine oil spills can be classified Into categories; 1) mechanical treatment using booms and skimmers, 2) chemical one utilizing dispersants, 3) controlled in-situ burning of spilled oils. In the present paper, characteristics, history, present issues, advantages and disadvanteges, and future applicability of in-situ burning technology which is nowadays winning much attention are summarized on the basis of a survey of related papers and other resources.

  • PDF

기술개발의 난이도와 누출정도가 기업의 공동연구개발 선호에 미치는 영향

  • 유평일;최상채;임광선
    • Journal of Technology Innovation
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 1997
  • Firms prefer in some specific conditions cooperative R&D to non-cooperative for developing technology. Previous studies on the conditions show firms want to choose cost-sharing type of cooperative R&D (the CS-RJV) rather than non-cooperative one when target technology is either 'relatively easy' or 'relatively difficult', and to join multiple-research or pararell-research type of cooperation (the PR-PJV) than to compete each other if technology is only 'relatively easy'. However, by introducing technological leakage as well as difficulty of technology. it is shown that this seemingly contrasted phenomenon almost disappears ; the PR-RJV can be also preferred by firms even is case of 'relatively difficult' technology only if there exists some extent of a technological leakage.

  • PDF

Hot Issue - IMDG Code 37차 개정판 주요 개정 내용

  • (사)한국포장협회
    • The monthly packaging world
    • /
    • s.266
    • /
    • pp.106-119
    • /
    • 2015
  • 국제해상위험물규칙(IMDG Code : International Maritime Dangerous Goods Code)은 1956년 유엔 경제사회이사회(UN ECOSOC)의 위험물운송 전문가 위원회에서 제정한 "위험물 운송에 관한 유엔권고"(일명, 오렌지 북)를 기본골격으로 국제해사기구가 1965년 제정한 포장 위험물의 해상운송 시 적용하는 국제규칙이다. IMDG Code에는 위험물을 그 특성에 따라 제1급(화약류)부터 제9급(기타 위험물)까지로 분류하고, 이들 위험물의 표시 및 표찰, 포장방법 및 포장용기 기준, 선적서류, 선박 적재방법 및 위험물 상호 간의 격리 등 포장 위험물의 해상운송에 관한 기본원칙이 규정되어 있다. 또한 IMDG Code에는 위험물의 화재 또는 누출 시 비상대응절차, 인명사고 시 의료응급처치지침, 화물고박지침 및 선박에서 살충제의 안전사용 방법 등에 관한 규정도 수록되어 있다. 본 고에서는 2년마다 개정되고 있는 IMDG Code 37차 개정판의 주요 개정내용을 지난 달에 이어 살펴보도록 한다.

  • PDF

AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF GLASS IONOMER CEMENT (Glass Ionomer Cement의 변록누출(邊綠漏出)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Joo, Kwang-Seop;Yoo, Kun-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.101-106
    • /
    • 1981
  • The purpose of this study was to estimate the ability of the marginal fit of Glass ionomer cement. Using the human extracted teeth and 2% acqueous solution of methylene blue, the author investigated the marginal penetration of dye in restorative materials such as Amalgam, Hi-Pol, Glass ionomer cement, Estic microfill and Restodent. The results were as follows. 1. All filling materials showed some degree of marginal penetration. 2. Glass ionomer cement revealed nearly the same microleakage as Estic microfill and Hi-Pol, but showed inferior effect of the marginal seal as compared with Restodent. 3. It is appeared that Amalgam has more effective ability of the marginal fit than the others within a week.

  • PDF

THE STUDY ON THE MICROLEAKAGE OF THE RESTORATION WITH SELF-ETCHING PRIMING/BONDING AGENT (Self-etching priming/bonding agent를 이용한 수복에서 microleakage에 관한 연구)

  • Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • Self-etching priming bonding system was recently developed in order to simplify the clinical skills & save chair time after continuous improvements on dentin bonding agents. To test the magnitude of microleakage of a new "self-etching priming bonding agent" using sound premolar 4th, 5th, 6th generation dentin bonding agent was applied. Measure the magnitude of infiltration to the gap of enamel-restoration interface and dentin-restoration interface. After bonding of composite resin to sample surfaces according to the manufactures direction and 500 times thermocycling on dwell time 30 second, and microleakage was measured by the ratio of the depth to the axial wall and the magnitude of infiltration. Afterward analyzed by ANOVA test. The result were as follows ; 1. Enamel groups showed lesser microleakage (Group I, II, III, IV) than dentin groups(Group V, VI, VII, VIII). (p<0.05) 2. There are no statical differences among the dentin groups, in enamel groups, group IV showed more microleakage than group I, II, III. (p<0.05). For a clinical acceptance, better enamel marginal adaptation is required.

  • PDF

A Study on the Simplified Estimating Method of Off-site Consequence Analysis for Aqueous Ammonia (암모니아수의 농도별 간이 영향평가 방법 연구)

  • Jung, Yu-kyung;Heo, Hwajin;Yoo, Byungtae;Yoon, Yi;Yoon, Junheon;Ma, Byungchol
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.49-57
    • /
    • 2016
  • Aqueous ammonia is widely used in household cleaners, fertilizers and denitrification process. It is usually treated in concentrations from 10 % to 30 %, and release accidents have occurred frequently. In this study, we developed a simplified estimating method and equation to calculate threat zone easily in case of emergency due to release accident of aqueous ammonia. We calculated the consequence distance for toxic endpoints of aqueous ammonia(concentration 10 % ~ 30 %) at different puddle areas($1m^2{\sim}500m^2$) using the ALOHA program. Based on the result, we analyzed the relationship between concentration and puddle area with the threat zone and created the equation.

Appropriateness Assessment of Dike Height of a Chemical Plant through Development of a Hazardous Chemical Leakage Trajectory Evaluation Module (유해화학물질 누출궤적 평가모듈 개발을 통한 화학공장 방류벽 높이의 적정성 평가)

  • Yoo, Byungtae;Kim, Hyeonggi
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.121-129
    • /
    • 2019
  • The Chemical Control Act of 2015 was enhanced to ensure the safe management of hazardous chemicals. In particular, there have been substantial changes in the standards for the installation and management of handling facilities for manufacturing and storing hazardous chemicals. However, some standards for handling facilities are difficult to implement due to a lack of physical space or because of safety accidents during facility improvements. Therefore, the Safety assessment system (SAS) has been operating for such facilities since 2018. This study developed a leakage trajectory evaluation module that can easily evaluate the outside of a dike for safety evaluation. We analyzed two case studies on a dike for hydrochloric acid and sulfuric acid storage tanks with this module and suggest a reasonable plan for the facility. We believe that it will be possible to more easily submit SAS reports at chemical plants by using this evaluation module. This study is expected to contribute to the improvement of the safety design of hazardous chemical handling facilities.

A Study on the Development of Installation and Management of Safety Shower (Safety shower 설치 및 관리기준 개선에 관한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • Currently chemical plant risk have been issued by occurring frequent accidents. Accidents can be generally composed of fire, explosion, release in chemical plant. In case of fire and explosion, accident victims are occurred immediately after accident but release accident, late emergency response cause damage to worker. Especially, there are many victims by late emergency response against chemical exposure to skin. In case of chemical exposure to skin, irreversible damage like death, blindness, burn can be prevented by washing immediately. Safety shower can provide the cleaning for chemical exposure to eye, skin. Most of chemical plants are built in 1980s so equipment become superannuated. In this reason, safety shower also cannot operate normally in emergency situation. Therefor safety shower should be managed by installation and management guideline. This study perform the establishment guideline for safety shower installation and inspection to increase the reliability.

Optimization of Gas Detector Location by Analysis of the Dispersion Model of Hazardous Chemicals (유해화학물질의 확산 모델 분석을 통한 가스감지기 위치 최적화)

  • Jeong, Taejun;Lim, Dong-Hui;Kim, Min-Seop;Lee, Jae-Geol;Yoo, Byung Tae;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The domestic gas detector installation standards applied to gas detectors, which are one of the facilities that can prevent accidents such as fire, explosion, and leakage that can cause serious industrial accidents, do not take into account the behavioral characteristics of hazardous chemicals in the atmosphere. It can be seen that the technical basis is insufficient because the standard is applied. Therefore, in this study, the size of the leak hole for each facility mainly used in chemical plants and the diffusion distance according to the concentration of interest of hazardous chemicals were analyzed, and based on this, the optimal installation distance for gas detectors for each material was suggested. Using the method presented in this study, more economical and effective gas detector installation can be expected, and furthermore, it can be expected to help prevent serious industrial accidents.

THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS (법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향)

  • Koo, Bong-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.452-459
    • /
    • 2006
  • Competition will usually develop between the opposing walls as the restorative resin shrinks during polymerization. Magnitude of this phenomenon may be depended upon cavity configuration and volume. The purpose of this sturdy was to evaluate the effect of cavity configuration and volume on microleakage of composite resin restoration that has margins on the enamel site only. The labial enamel of forty bovine teeth was ground using a model trimmer to expose a flat enamel surface. Four groups with cylindrical cavities were defined, according to volume and configuration factor(Depth x Diameter / C-factor) - Group I : 1.5 mm ${\times}$ 2.0 mm / 4.0, Group II : 1.5 mm ${\times}$ 6.0 mm / 2.0, Group III : 2.Omm ${\times}$ 1.72 mm / 5.62, Group IV : 2.0 mm ${\times}$ 5.23 mm / 2.54. After treating with fifth-generation one-bottle adhesive - BC Plus$^{TM}$ (Vericom, AnYang, Korea), cavities were bulk flted with microhybrid composite resin - Denfill$^{TM}$ (Vericom). Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Specimens were thermocycled 500 times between 5$^{\circ}$C and 55$^{\circ}$C for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}$A) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. The results were as follows: 1. Small cavity volume showed lower microleakage score than large one, however, there was no statistically significant difference. 2. There was no relationship between cavity configuration and microleakage. Factors of cavity configuration and volume did not affect on microleakage of resin restorations with enamel margins only.