• Title/Summary/Keyword: 유방촬영

Search Result 248, Processing Time 0.027 seconds

Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis (디지털 유방단층촬영의 피폭선량 경감을 위한 수동 촬영조건의 가이드라인 제시)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.483-491
    • /
    • 2016
  • The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure, the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients' Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

Usability of Digital Tomosynthesis in Mammography (유방 촬영에서 디지털 토모신테시스(Digital Tomosynthesis)의 유용성)

  • Lee, Mi-Hwa;Jung, Hong-Rayng
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.151-152
    • /
    • 2015
  • 유방 검사에서 Tomosynthesis는 Mammogram과 비교하여 유방 병변 구별에 우수하고 확연한 대조도 차이를 보이며 추가적인 유방촬영 검사나 재촬영을 감소시킴으로서 장기적으로 환자의 피폭선량이 감소하는 효과를 보이므로 유방 병변 진단의 효과를 높일 수 있는 유용한 검사이다.

  • PDF

Incidental Extramammary Findings on Preoperative Breast MRI in Breast Cancer Patients: A Pictorial Essay (유방암 환자의 수술 전 유방 MRI에서 우연히 발견된 유방 외 소견: 임상화보)

  • Jin-A Ryoo;Shin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.372-385
    • /
    • 2023
  • Breast cancer is one of the most common cancers and causes several complications in females. Currently, MRI is a necessary method for preoperative studies in patients with breast cancer. A high frequency of breast MRI can lead to an increase in the number of incidental extramammary findings. Moreover, it can provide accurate preoperative workup; therefore, the prognosis of patients can be improved. Herein, we provide several extramammary findings, including the mediastinum, lung, upper abdomen, bone, and soft tissue, correlating with US, chest CT, liver MRI, PET-CT, and bone scan.

Analysis of Factors Related to Pain Relief on Modified Mammography (변형 유방촬영술시 통증완화에 따른 요인 분석)

  • Jang, Myung Mi;Kim, Hwa Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.413-421
    • /
    • 2017
  • Mammography, the basic test for finding and treating increased breast cancer, gives the anxiety of cancer and radiation exposure to most women. In addition, it gave very severe compression pain, so we studied the degree of pain and tried to reduce the pain. The purpose of this study is to compare and analyze the modified imaging technique and the basic imaging technique based on clinical experience, respectively. The subjects of this study were 160 women from 30 to 60 years old who visited to Seoul Boramae Hospital operated by Seoul National University Hospital from February to March 2017 for breast screening. Modified 80 persons and 80 persons were divided into two groups, and each group was asked to fill out questionnaires sequentially without knowing the subjects. The first method is a modified method in which an automatic pedal is divided into four or more presses, a manual pressure is used together, and an attitude is described in detail. Secondly, we used only the automatic pedal compression method and press it within 1-3 times. In the mean of the pain distribution, the experimental group (modified method) was 2.49 and the control group (basic method) had an average of 4.86, which showed 48.8% less pain. In this modified method, the pain scores of the experimental group were lower than those of the control group, and the degree of the pain was statistically significant.

A Study on Development of Mammo Pad and Analysis of Factors Affecting Compression Pain for Mammography (유방 방사선 검사를 위한 압박 패드의 제작 및 유방 압박 통증에 영향을 주는 요인 분석)

  • Kim, Do-Hee;Yi, Ann;Kwon, Bo-Ra;Ku, Hong-Uk;Bang, Yong-Sik;Cho, Myeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.629-636
    • /
    • 2021
  • The purpose of this study was to identify the effects of mammo pad made of different kinds of materials on the reduced inconvenience and compression pains of patients to examine plausible interchangeability of existing pads made of single kind of material, and to examine the changes in pains of patients taking mammography and various factors therein. The high-hardness and highly-elastic mammo pressure pads, capable of replacing existing mammo pad of "H" company, were manufactured, and the display quality of mammography obtained from respective mammo pad were compared to each other to appraise the availability of manufactured mammo pad. In addition, 200 patients, who came to a general hospital in Seoul, were selected as subjects for the survey employing a questionnaire which was distributed to the subjects from December 2018 to March 2020 to identify the factors involved with the mammo pad of patients while taking mammography. The results of mammography obtained from both of the existing and newly manufactured mammo pad revealed appropriate display qualities fell within the range of clinical criteria. Besides, the factors associated with changing compression pains of patients taking mammography were analyzed wherefrom the general factors in the following order of age, height, and BMI index appeared, while the experiential and female factors appeared as in the following order: presence of menstruation, experience of child-birth, experience of breast feeding, menopause, grade of breast, shape of breast, and experience of mammography. In conclusion, the following factors comprising the age, experience of breast feeding, experience of mammography, and menopause rendered approximately 54% of power of explaining the degree of changing pains during mammography. Regarding the changes in compression pains while taking mammography, the increasing experience of mammography of patients rendered approximately 0.26 times more at the intermediate range of compression pains and approximately 0.14 times more at the range of severe pains.

Microcalcification Extraction by Wavelet Transform and Automatic Thresholding (웨이브렛 변환과 자동적인 임계치 설정에 의한 미세 석회화 검출)

  • Won, Chul-Ho;Seo, Yong-Su;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.4
    • /
    • pp.482-491
    • /
    • 2005
  • In this paper, we proposed the microcalcification detection algorithm which is based on wavelet transform and automatic thresholding method in the X-ray mammographic images. Digital X-ray imaging system is essential equipment in the field diagnosis and is widely used in the various fields such as chest, fracture of a bone, and dental correction. Especially, digital X-ray mammographic imaging is known as the most important method to diagnose the breast cancer, many researches to develop the imaging system are processing in country. In this paper, we proposed a microcalcifications detection algorithm necessary in the early phase of breast cancer diagnosis and showed that a algorithm could effectively detect microcalfication and could aid diagnosis-radiologist.

  • PDF

Digital Mammography as a Screening Tool in Korea (국가암검진사업에서 디지털 유방촬영술의 현황과 과제)

  • Soo Yeon Song;Seri Hong;Jae Kwan Jun
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.2-11
    • /
    • 2021
  • More than 4 million women undergo breast cancer (BC) screening with mammography each year in Korea. Digital mammography (DM) was introduced in 2000, and it has been reported to have a higher diagnostic accuracy than screen-film mammography (SFM) or computed radiography (CR) in women with dense breasts. According to a study using data from the National Cancer Screening Program for BC, the diagnostic accuracy of DM was higher than those of SFM and CR, regardless of age, breast density, and screening round. Currently, despite high supply rate among OECD countries, the distribution of DM equipment is approximately 35% in Korea. For quick replacement with DM, it will be necessary to improve its fee for the National Health Insurance and support an educational program for radiologists. In addition, efforts should be made to increase the accessibility of DM.