• Title/Summary/Keyword: 위치분석

Search Result 15,139, Processing Time 0.046 seconds

Effect of Dose Rate Variation on Dose Distribution in IMRT with a Dynamic Multileaf Collimator (동적다엽콜리메이터를 이용한 세기변조방사선 치료 시 선량분포상의 선량률 변화에 따른 효과)

  • Lim, Kyoung-Dal;Jae, Young-Wan;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Purpose: To evaluate dose distribution differences when the dose rates are randomly changed in intensity-modulated radiation therapy using a dynamic multileafcollimator. Materials and Methods: Two IMRT treatment plans including small-field and large-field plans were made using a commercial treatment planning system (Eclipse, Varian, Palo Alto, CA). Each plan had three sub-plans according to various dose rates of 100, 400, and 600 MU/min. A chamber array (2D-Array Seven729, PTW-Freiburg) was positioned between solid water phantom slabs to give measurement depth of 5 cm and backscattering depth of 5 cm. Beam deliveries were performed on the array detector using a 6 MV beam of a linear accelerator (Clinac 21EX, Varian, Palo Alto, CA) equipped with 120-leaf MLC (Millenium 120, Varian). At first, the beam was delivered with same dose rates as planned to obtain reference values. After the standard measurements, dose rates were then changed as follows: 1) for plans with 100 MU/min, dose rate was varied to 200, 300, 400, 500 and 600 MU/min, 2) for plans with 400 MU/min, dose rate was varied to 100, 200, 300, 500 and 600 MU/min, 3) for plans with 600 MU/min, dose rate was varied to 100, 200, 300, 400 and 500 MU/min. Finally, using an analysis software (Verisoft 3.1, PTW-Freiburg), the dose difference and distribution between the reference and dose-rate-varied measurements was evaluated. Results: For the small field plan, the local dose differences were -0.8, -1.1, -1.3, -1.5, and -1.6% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +0.9, +0.3, +0.1, -0.2, and -0.2% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.4, +0.8, +0.5, +0.3, and +0.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). On the other hand, for the large field plan, the pass-rate differences were -1.3, -1.6, -1.8, -2.0, and -2.4% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +2.0, +1.8, +0.5, -1.2, and -1.6% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.5, +1.9, +1.7, +1.9, and +1.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). In short, the dose difference of dose-rate variation was measured to the -2.4~+2.0%. Conclusion: Using the Varian linear accelerator with 120 MLC, the IMRT dose distribution is differed a little <(${\pm}3%$) even though the dose-rate is changed.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Clinical Features of Acute Nonspecific Mesenteric Lymphadenitis and Factors for Differential Diagnosis with Acute Appendicitis (급성 비특이성 장간막 림프절염의 임상 소견과 급성 충수돌기염과의 감별 인자)

  • Shin, Kyung Hwa;Kim, Gab Cheol;Lee, Jung Kwon;Lee, Young Hwan;Kam, Sin;Hwang, Jin Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • Purpose: Although acute nonspecific mesenteric lymphadenitis (ANML) is probably common cause of abdominal pain in children, which can be severe enough to be an abdominal emergency, the clinical features of mesenteric lymphadenitis are not clear. Also, a differential diagnosis with acute appendicitis (APPE) is indispensable to avoid serious complications. The clinical features of ANML were determined, and the risk factors for differential diagnosis with APPE were analyzed. Methods: Between November 2000 and May 2001, data from 26 patients (aged 1 to 11 years) with ANML and 21 patients (aged 2 to 13 years) with APPE were reviewed. ANML was defined as a cluster of five or more lymph nodes measuring 10 mm or greater in their longitudinal diameter in the right lower quadrant (RLQ) without an identifiable specific inflammatory process on the ultrasonographic examination. There were risk factors on patient's history, physical examination, and laboratory examination; the location of abdominal pain, abdominal rigidity, rebound tenderness, fever, nocturnal pain, the vomiting intensity, the diarrhea intensity, the symptom duration, and the peripheral blood leukocytes count. Results: Of the 26 ANML patients and 21 APPE patients, abdominal pain was noted on periumbilical (76.9% vs 14.2%), on RLQ (11.5% vs 71.4%), with abdomen rigidity (7.6% vs 80.9%), with rebound tenderness (0.0% vs 76.1%)(p<0.05), in the lower abdomen (11.5% vs 14.2%), and at night (80.8% vs 100.0%) (p>0.05). The clinical symptoms were vomiting (38.4% vs 90.4%), the vomiting intensity ($1.5{\pm}0.7$ [1~3]/day vs $4.5{\pm}2.9$ [1~10]/day), diarrhea (65.3% vs 28.5%) (p<0.05), and fever (61.5% vs 76.2%)(p>0.05). The period to the subsidence of abdominal pain in the ANMA patients was $2.5{\pm}0.5$ (2~3) days. The laboratory data showed a significant difference in the peripheral blood leukocytes count ($8,403{\pm}1,737[5,900{\sim}12,300]/mm^3\;vs\;15,471{\pm}3,749[5,400{\sim}20,800]/mm^3$)(p<0.05). Discriminant analysis between ANML and APPE showed that the independent discriminant factors were a vomiting intensity and the peripheral blood leukocytes count and the discriminant power was 95.7%. Conclusion: The clinical characteristics of ANML were abrupt onset of periumbilical pain without rigidity or rebound tenderness, a mild vomiting intensity, normal peripheral leukocytes count, and relatively short clinical course. If the abdominal pain persist for more than 3 days, and/or the vomiting intensity is more than 3 times/day, and/or the peripheral leukocytes count is over $13,500/mm^3$, abdominal ultrasonography is recommended to rule out APPE.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Nitrogen Removal Rate of A Subsurface Flow Treatment Wetland System Constructed on Floodplain During Its Initial Operating Stage (하천고수부지 수질정화 여과습지의 초기운영단계 질소제거)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.278-283
    • /
    • 2003
  • This study was carried out to examine the nitrogen removal rate of a subsurface-flow treatment wetland system which was constructed on floodplain of the Kwangju River from May to June 2001. Its dimensions were 29m in length, 9m in width and 0.65m in depth. A bottom layer of 45cm in depth was filled with crushed granite with about $15{\sim}30\;mm$ in diameter and a middle layer of 10cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds (Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju River flowed into it via a pipe by gravity flow and its effluent was funneled back into the river. The height of reed stems was 44.2 cm in July 2001 and 75.3cm in September 2001. The number of stems was increased from $80\;stems/m^2$ in July 2001 to $136\;stems/m^2$ in September 2001. Volume and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged 40.0 and $39.2\;m^3/day$, respectively. Hydraulic detention time was about 1.5 days. Average nitrogen uptake by reeds was $69.31\;N\;mg/m^2/day$. Removal rate of $NO_3-N$, $NH_3-N$, T-N averaged 195.58, 53.65, and $628.44\;mg/m^2/day$, respectively. Changes of $NO_3-N$ and $NH_3-N$ abatement rates were closely related to those of wetland temperatures. The lower removal rate of nitrogen species compared with that of subsurface-flow wetlands operating in North America could be attributed to the initial stage of the system and inclusion of two cold months into the six-month monitoring period. Increase of standing density of reeds within a few years will develop both root zones suitable for the nitrification of ammonia and surface layer substrates beneficial to the denitrification of nitrates into nitrogen gases, which may lead to increment in the nitrogen retention rate.

Minimally Invasive Coronary Artery Bypass Grafting (소침습적 관상동맥우회술)

  • Na, Chan-Young;Lee, Young-Tak;Park. Joong-Won;Chung, Do-Hyun;Jung, Ill-Sang;Jung, Yoon-Seup;Kim, Ok-Sung;Bang, Jung-Hyun;Lee, Sub;Chung, Chul-Hyun;KIM, Woong-Han;Park, Young-Kwan;Kim, Chong-Whan;Hong, Sung-Nok;Han, Jae-Jin;Lee, Gun
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.118-124
    • /
    • 1998
  • Minimally invasive coronary artery bypass grafting without using cardiopulmonary bypass (CPB) is a recently accepted modality of myocardial revascularization prcedures which is particularly suitable to the patients with lesions in the left anterior descending(LAD) and the right coronary arteries. Of the consecutive 35 patients of coronary artery bypass grafting performed at Sejong General Hospital from March to August 1996, six patients underwent minimally invasive coronary artery bypass grafting without CPB. All had stenotic lesions of the LAD more than 90%. Bypass grafting of the LAD was approached through midline sternotomy in one, through ministernotomy in two, and through limited left anterior thoracotomy in three patients, respectively. The internal mammary arteries were prepared without the use of thoracoscope. The mobilized mammary arteries were connected directly to the LAD in 5 patients, and the anastomosis required interposition of a segment of the radial artery in the remaining one. The diagonal branch was revascularized with the saphenous vein graft at the same time in one patient. No blood transfusion was necessary in 2 patients, and average blood required during surgery was 800ml in 4 patients. All patients were extubated from 4 to 14 hours(mean 9 hours) after operation. Early postoperative coronary angiography in 5 patients between 7 and 10 days after surgery has proved full patency of the grafts. With these limited clinical experiences, the clinical results demonstrated that minimally invasive coronary artery bypass grafting without CPB is an useful procedure especially in patients with isolated lesion in the proximal LAD.

  • PDF

The Planting and Occurrence Status of Exotic Plants of the Folk Village as National Cultural Heritage - Focus in Hahoe.Yangdong.Hangae Villages - (국가지정 문화재 민속마을의 외래식물 식재 및 발생현황 - 하회.양동.한개마을을 대상으로 -)

  • Rho, Jae-Hyun;Oh, Hyun-Kyung;Han, Yun-Hee;Park, Kyung-Uk;Byun, Moo-Sup;Huh, Joon;Choi, Yung-Hyun;Shin, Sang-Sup;Lee, Hyun-Woo;Kim, Hyo-Jung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.1-19
    • /
    • 2013
  • This study was carried out to analyze distribution situation of alien plants and to propose management plan in the 3 Folk village in Gyeongsangbuk-do which is Cultural property designated by the State; Hahoe, Yangdong and Hangae. This research is for improve of sincerity of historical site and provide basic information which use about administration of preservation. The results are as follows. 1. Overall flora and alien plants appearance The total flora in the 3 folk villages were listed total 752 taxa including 127 families, 430 genera, 614 species, 5 subspecies, 100 varieties and 33 forms. Among them, woody plants take 263 taxa(35.0%) and herbaceous plants take 489 taxa (65.0%). Flora in the Hahoe, Yangdong and Hangae village were total 534, 479 taxa and 408 taxa and exotic plant index was 30.1%, 38.2% and 37.0% respectively. In types of exotic plants, ornamental exotic plants were 135 taxa, deciduous exotic plants were 21 taxa, cultivating exotic plants were 64 taxa, and naturalized exotic plants were 80 taxa and those result lead that the ornamental exotic plants is the highest ratio. According to the villages, Hahoe village had 161 taxa(30.1%), Yangdong Village had 183 taxa(38.2%), and Hangae village had 151 taxa(37.0%) that Yangdong village showed the most number of exotic plants. 2. Planting of landscape exotic plants in the unit cultural assets Meanwhile, Ornamental exotic plants in old house's gardens in Andong Hahoe village which is designated as a unit assets, those are total 30 taxa; followed by the Okyeon house(8 taxa) is highest and the Yangjindang(7), the Hadong house(6) and the Chunghyodang(5). Magnolia denudata appears the most as for 4 times and Campsis grandiflora etc. each took 2 times. Based on the Yangdong village, Gyeongju, that are found total 51 taxa; followed by the Dugok house(16 taxa) the Sujoldang(14), the Mucheondang(13), and the Sangchunheon (12). High appearance rate of ornamental exotic plants were Viburnum opulus for. hydrangeoides, Lycoris squamigera, Caragagna sinica and Magnolia denudata etc. Based on the Hangae village, Seongju, that are designated total 62 taxa; followed by the Jinsa house(35 taxa), the Gyori house(25), the Hanju head family house(20), and the Hahoe house(16). Taxa with high appearance rates were Caragana sinica, Juniperus chinensis var. horizontalis, Magnolia denudata, Viburnum opulus for. hydrangeoides, Chaenomeles speciosa etc. 3. Problems of exotic plant landscapes in the outer spaces of the folk villages Problems of exotic plant landscapes in the outer spaces of the Hahoe village are as follows. In lower of the Mansongjeong forest, Ambrosia artemisifolia, which are ecosystem disturbance plants designated by the Ministry of Environment, live with high dominance value. This should be have a remove with Sicyos angulatus immediately. In the Nakdong river bed around the Mansongjeong forest is covered with a riparian vegetation forest belt of Robinia pseudoacacia L. forest, Populus nigra var. italic community, and Populus x tomentiglandulosa community colony. Based on the Yangdong village, the planted or naturally distributed Ailanthus altissima colony, sporadically distributed Robinia pseudoacacia as well as Amorpha fruticosa are detected all over the village and ecotones. Based on the Hangae village, Ailanthus altissima and Robinia pseudoacacia are sporadically distributed around the village and there is a sign of spreading. similarity of exotic plantsis 47.0% to 48.6% and a reason why this happened is all of research site in Gyeongsanbuk-do and that is why growth norm of plant is similar, exotic plant which is sales for ornamental and it infer to require related countermeasure of each villages and joint related countermeasure.

Wind and Flooding Damages of Rice Plants in Korea (한국의 도작과 풍수해)

  • 강양순
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s02
    • /
    • pp.45-65
    • /
    • 1989
  • The Korean peninsular having the complexity of the photography and variability of climate is located within passing area of a lots of typhoon occurring from the southern islands of Philippines. So, there are various patterns of wind and flooding damages in paddy field occuring by the strong wind and the heavy rain concentrated during the summer season of rice growing period in Korea. The wind damages to rice plants in Korea were mainly caused by saline wind, dry wind and strong wind when typhoon occurred. The saline wind damage having symptom of white head or dried leaves occurred by 1.1 to 17.2 mg of salt per dry weight stuck on the plant which was located at 2. 5km away from seashore of southern coastal area during the period(from 27th to 29th, August, 1986) of typhoon &Vera& accompanying 62-96% of relative humidity, more than 6 m per second of wind velocity and 22.5 to 26.4$^{\circ}C$ of air temperature without rain. Most of the typhoons accompanying 4.0 to 8. 5m per second of wind and low humidity (lesp an 60%) with high temperature in the east coastal area and southen area of Korea. were changed to dry and hot wind by the foehn phenomenon. The dry wind damages with the symptom of the white head or the discolored brownish grain occurred at the rice heading stage. The strong wind caused the severe damages such as the broken leaves, cut-leaves and dried leaves before heading stage, lodging and shattering of grain at ripening stage mechanically during typhoon. To reduce the wind damages to rice plant, cultivation of resistant varieties to wind damages such as Sangpoongbyeo and Cheongcheongbyeo and the escape of heading stage during period of typhoon by accelerating of heading within 15th, August are effective. Though the flood disasters to rice plant such as earring away of field, burying of field, submerging and lodging damage are getting low by the construction of dam for multiple purpose and river bank, they are occasionally occurred by the regional heavy rain and water filled out in bank around the river. Paddy field were submerged for 2 to 4 days when typhoon and heavy rain occurred about the end of August. At this time, the rice plants that was in younger growing stage in the late transplanting field of southern area of Korea had the severe damages. Although panicles of rice plant which was in the meiotic growing stage and heading stage were died when flooded, they had 66% of yield compensating ability by the upper tilling panicle produced from tiller with dead panicle in ordinary transplanting paddy field. It is effective for reduction of flooding damages to cultivate the resistant variety to flooding having the resistance to bacterial leaf blight, lodging and small brown planthopper simultaneously. Especially, Tongil type rice varieties are relatively resistant to flooding, compared to Japonica rice varieties. Tongil type rice varieties had high survivals, low elongation ability of leaf sheath and blade, high recovering ability by the high root activity and photosynthesis and high yield compensating ability by the upper tillering panicle when flooded. To minimize the flooding and wind damage to rice plants in future, following research have to be carried out; 1. Data analysis by telemetering and computerization of climate, actual conditions and growing diagnosis of crops damaged by disasters. 2. Development of tolerant varieties to poor natural conditions related to flooding and wind damages. 3. Improvement of the reasonable cropping system by introduction of other crops compensating the loss of the damaged rice. 4. Increament of utilization of rice plant which was damaged.

  • PDF

The Evaluation of Forest-road Network Considering Optimum Forest-road Arrangement and Yarding Function (최적임도배치(最適林道配置) 및 집재기능(集材機能)을 고려(考慮)한 임도배치망(林道配置網) 평가(評價))

  • Park, Sang Jun;Bae, Sang Tae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.19
    • /
    • pp.45-54
    • /
    • 2001
  • This study was carried out to provide fundamental data for prospective forest-road project and forest-road network arrangement through appraising existing forest-road network with density, extension distance, maximum yarding distance and yarding area, position of forest-road line considered above foundation of two theories, one is "theory of optimal forest-road density" which has expense for yarding cost and constructing forest-road minimized, the other is "theory of optimal forest-road arrangement" which has investment effect maximized. The results are as follows. 1. In density and extension distance of the forest-road by site, it was showed up that density of existing forest-road is lower than that of calculated forest-road. So, it is thought that some additional forest-roads have to be constructed. 2. In the arrangement of the forest-road network by site, it was showed up that the arrangement of calculated forest-road is higher than that of existing forest-road arrangement for the forestry and yarding function. So, it is thought that the arrangement of forest-road network have to be considered to maximize the investment effect. 3. In "mean maximum distance for yarding" and "mean area which yarding can be done" by horizontal and inclined distance, the existing forest-road networks were different from those of calculated forest-road network. So, calculated forest-road network making investment effect maximize is more effective than existing forest-road network. Hence, in prospective forest-road project, it is needed that forest-road network having "area which yarding can be done" maximized through considering function for yarding have to be constructed.

  • PDF

A Novel in Vitro Method for the Metabolism Studies of Radiotracers Using Mouse Liver S9 Fraction (생쥐 간 S9 분획을 이용한 방사성추적자 대사물질의 새로운 체외 측정방법)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Dong-Hyun;Lee, Sang-Yoon;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.325-329
    • /
    • 2004
  • Purpose: Usefulness of mouse liver S9 fraction was evaluated for the measurement of the metabolites in the in vitro metabolism study of $^{18}F$-labeled radiotracers. Materials and Methods: Mouse liver S9 fraction was isolated at au early step in the course of microsome preparation. The in vitro metabolism studies were tarried out by incubating a mixture containing the radiotracer, S9 fraction and NADPH at $37^{\ciirc}C$, and an aliquot of the mixture was analyzed at the indicated time points by radio-TLC. Metabolic defluorination was further confirmed by the incubation with calcium phosphate, a bone mimic. Results: The radiotracer $[^{18}F]1$ underwent metabolic defluorination within 15 min, which was consistent with the results of the in vivo method and the in vitro method using microsome. Radiotracer $[^{18}F]2$ was metabolized to three metabolites including $4-[^{18}F]fluorobenzoic$ acid within 60 min. It is likely that the one of these metabolites at the origin of radio-TLC was identical with the one that obtained from the in vivo and in vitro (microsome) method. Compared with the in vitro method using microsome, the method using S9 fraction gave a similar pattern of the metabolites but with a different ratio, which can be explained by the presence of cytosol in the S9 fraction. Conclusion: These results suggest that the findings of the in vitro metabolism studies using S9 fraction can reflect the in vivo metabolism of novel radiotracers in the liver. Moreover, this method can be used as a tool to determine metabolic defluorination along with calcium phosphate absorption method.