• Title/Summary/Keyword: 운동응답 분석

Search Result 220, Processing Time 0.036 seconds

Evaluation of the Effect of Input Motions on Earthquake-Induced Settlement of Embankment Dams (입력지진파에 따른 지진 시 필댐의 침하량 영향관계 분석)

  • Jo, Seong-Bae;Kim, Nam-Ryong;Kim, Tae Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.509-520
    • /
    • 2020
  • Currently, the criteria for input motions used in dam seismic design are clearly presented in general provisions of seismic design (KDS 17 10 00), and seismic ground motion records should be matched to the standard design response spectrum. However, the effect on the results is not assessed according to the selection of the seismic ground motion records, making it difficult to select seismic input motions. Therefore, in this study, the change in the amount of crest settlement of an embankment dam was assessed through numerical analysis after matching the seismic ground motion records of domestic and overseas earthquakes in accordance with the standard design response spectrum provided in the seismic design code (KDS 17 10 00). The results showed that the behavior of the upper part of the embankment, such as maximum acceleration at the crest and amplification through the dam, rather than the effect of free-field acceleration, had a greater effect on the amount of crest settlement. Moreover, it was confirmed that even an input seismic motion matched to the standard design response spectrum can make a difference in settlement depending on the characteristics of amplification through a dam body.

Evaluation of the Site Specific Ground Response in Korean Urban Site (국내 도시지역의 지반응답특성 거동 평가)

  • Shin, Dea-Sub;Kim, Hu-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.250-255
    • /
    • 2017
  • When an earthquake occurs, it is necessary to evaluate the site-specific ground response while considering ground characteristics in seismic design. The design seismic force of Korean seismic design criteria is borrowed from the Uniform Building Code(UBC-1997). However, the criteria are based on the ground characteristics of the United States, which are different from the ground characteristics in Korea, and using them could cause over-or under-designing. Therefore, it is important to develop a proper design response spectrum for Korean ground characteristics. In this study, 158 ground sites in Korean urban areas were selected and compared to those in the western part of the United States, and their site-specific ground responses were analyzed. The classification standard in the seismic design criteria classifies the 158 sites into 37 sites, 107 sites, and 14 sites. Using 7 earthquake inputs, the criteria were compared for each group.The Korean design response spectrum underestimates the amplification of the short-period range and overestimates the amplification in the long-period range. There were large differences in the results of the and sites,which account for 77 percent of the 158 sites. Therefore, there is a need to modify the amplification factor in the Korean seismic criteria to properly reflect Korean ground characteristics.

Convergence effect on oral Health Awareness of Oral Health Education and oral Health Knowledge of Early Childhood Education (유아교육학과 학생의 구강보건교육과 구강보건지식이 구강보건인식에 융합적으로 미치는 영향)

  • Yoon, Sung-Uk
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.71-78
    • /
    • 2019
  • This Convergence study aimed to analyze the oral health education, oral health awareness and oral health knowledge of early childhood education' students. Questionnaire survey on the of five universities early childhood education' 314 students in Daegu and Gyeongbuk provinces. Average score of oral health awareness was 3.62, which was high female students, 3rd grade, athlete, high case on oral health condition perception and childhood oral health education experience. Oral health knowledge correct answer of 15 items was average 9.63, which was higher female students, 3rd grade, nonsmokers, have received childhood oral health education, responded to the need for childhood oral health education. Regression analysis showed that Y (oral health awareness) = 2.350 + 0.242 (exercise) +0.387 (oral health education) +0.134 (childhood oral health education experience) +0.067 (oral health knowledge). In order to promote infants oral health of department of Early Childhood Education, it would be necessary to develop the systematic programs to perform the childhood oral health education.

정전구동 방식의 연동형 마이크로펌프의 제작

  • Hong, Pyo-Hwan;Jeong, Dong-Geon;Gong, Dae-Yeong;Pyo, Dae-Seung;Lee, Jong-Hyeon;Lee, Dong-In;Jo, Chan-Seop;Kim, Bong-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.448-448
    • /
    • 2013
  • 최근 생물학적 분석 기구에서 시료를 처리, 분리, 검출, 샘플링 또는 분석하기 위해 사용되는 마이크로펌프(Micropump)에 대한 관심이 높아지고 있다. 또한 전자소자의 성능과 신뢰성의 증진을 위한 전자소자의 열 문제를 해결하기 위해 냉각장치로 마이크로 펌프가 적용되기도 한다. 그 외에도 마이크로펌프는 다양한 분야에 응용이 가능하다. 마이크로펌프는 작동 방식에 따라 압전형, 공압형, 열공압형, 연동형 등의 여러 종류로 분류되고 있다. 그중에서도 최근에는 연동형 마이크로 펌프의 개발이 각광받고 있다. 기존의 연동형 펌프들은 다중 챔버를 가지고 있으며, 각각의 챔버 내에서 Dead volume이 많이 발생할 뿐만 아니라 이상적인 연동운동과는 차이가 많이 나는 문제점을 가지고 있다. 또한 압전방식과 열공압방식은 느린 응답성으로 인해 효율적인 유체 이동이 어렵다. 본 논문에서는 이상적인 연동운동을 구현하기 위하여 기존의 연동형 펌프의 단점을 보완하고, 하나의 챔버에 다중전극 구조를 가지는 정전기력방식의 연동형 펌프를 개발하였다. 정전기력방식으로 펌프를 구동함으로써, 저전력으로 펌프구동이 가능하며, 하나의 챔버에 다중전극을 설치함으로써 이상적인 연동운동을 재현하였다. 그리고 Dead volume을 최소화 하였다. 또한, 빠른 반응속도로 인해 효율적인 유체 이동을 실현시킬 수 있었다. 본 연구에서 제안된 마이크로 펌프의 구성은 크게 챔버, 박막, Inlet/outlet hole으로 구성되었다. 챔버는 Si-wafer에 wet etching 공정으로 제작 하였고 그 위에 알루미늄 박막을 200 nm 증착시켰다. 챔버는 가로 32 mm, 세로 5 mm, 깊이는 $15{\mu}m$, 부피는 $200{\mu}l$으로 제작되었다. 박막은 폴리이미드(polyimide)를 사용하여 $3{\mu}m$의 두께로 제작 되었으며, 폴리이미드 박막 사이에는 200 nm 두께의 4개의 알루미늄 박막 전극을 삽입시켰다. 삽입된 4개의 전극에 개별적인 전기신호를 보냄으로써 연동운동이 가능하다. Inlet/outlet hole은 직경 2 mm의 크기로 제작되었으며, 튜브를 연결하여 유체가 흐를 수 있는 체널을 형성하였다. 제작된 마이크로 펌프의 구동전압은 115 V이며, 인가되는 주파수를 1 Hz~100 KHz까지 변화시켜 유량을 측정하였다. 작동 유체는 공기이며, 유량측정은 튜브 내에 물방울을 삽입하여 시간에 따른 이동거리를 관측하였다. 측정결과 2.2 KHz에서 2.4 mm/min의 가장 높은 유량을 확인할 수 있었다. 본 연구를 통해 제안된 연동형 마이크로펌프는 이상적인 연동운동이 가능함으로써 기존의 연동형 방식의 문제점을 보완하였으며, 생명과학, 의학, 화학 등의 분야에서 적용이 가능하리라 기대된다.

  • PDF

Revision of a Questionnaire to Assess Health Behaviors in Obese Children (비만 아동에 대한 설문지의 분석과 재구성)

  • Park, So Eun;Yom, Hye Won;Seo, Jeong Wan;Lee, He Jin;Park, Hye Sook
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.215-227
    • /
    • 2004
  • Purpose: The prevalence of childhood obesity has increased dramatically. It is important to know about life style and dietary habits of the obese children because the treatment of childhood obesity focuses on using behavioral modification techniques. We aimed to develop a questionnaire for the purpose of providing convenient and useful guidance to pediatricians who evaluate and treat obese children. Methods: Previously developed questionnaire was given to 94 obese children and their parents who had visited clinic for obese children and adolescents. We analyzed response rates on questions and reliability between children and their parents. Results: The response rates on questions were somewhat high. Agreement of paired questions of both parents and children was also moderately high (63~92%). It is acceptable to complete questions by either parents or children alone. Items for hours of playing video games or computer, maternal job, kind of consuming beverage and food outside home were added. Conclusion: We concluded that some questions are not needed to be given to both parents and their children. It would be better to have parents record life style of their children and to have children record their food intake with physical activity outside home.

  • PDF

A Study on the Noise Characteristics of Linear Motor by Improved Velocity Profile (개선된 속도 프로파일에 의한 선형전동기 소음 특성에 관한 연구)

  • Jeon, Jin-Yong;Oh, Joon-Tae;Kim, Gyu-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.595-597
    • /
    • 2008
  • 자동반송 장비의 주행축에 적용되는 횡자속 선형전동기는 위치제어를 목적으로 한다. 위치제어는 자동 반송 장비가 최소구동시간에 최대의 생산을 할 수 있도록 성능이 우수한 구동프로파일을 사용하게 되는데, 어떤 종류의 구동 프로파일을 적용하느냐에 따라 시스템 전체의 응답 속도는 물론이고 진동과 소음을 최소화하여 전체 시스템의 성능을 좌우하게 된다. 일반적으로 사용되는 사다리꼴 속도 프로파일은 변화가 일정한 가감속 전류를 필요로 하고, 전체 구동시간이 짧아 간단한 시스템에 널리 사용되고 있지만, 가속의 끝점과 감속 구간의 시작점에서 급격한 속도 변화에 따른 져크(Jerk)가 발생하여 기구부에 충격이 가해지며, 이로 인한 진동과 소음을 유발해 순간적으로 큰 동적 에러를 발생시킨다. 따라서, 본 연구에서는 부드러운 속도 프로파일을 가지며 운동의 시작점과 끝점에서 '0'의 가속과 져크를 가지는 고차원의 구동 프로파일을 제시하고 횡자속 선형전동기에 적용하여 소음 특성을 분석하였다.

  • PDF

A Study of Reduction Vibration Position Control of PMSM Using Notch Filter (노치필터를 이용한 PMSM의 진동 억제 위치 제어에 대한 연구)

  • Kwon, Ki-hyun;Jung, Sung-chul;Ko, Jong-sun
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.131-134
    • /
    • 2014
  • PMSM(Permanent Magnet Synchronous Motor)은 가공기, 로봇, 공장 자동화 등 현재까지도 산업 시스템 전반에 널리 쓰이고 있으며, 그에 대한 연구도 활발히 진행되고 있다. 하지만 PMSM에 부하를 인가하거나 혹은 기계 몸체와의 결합 과정에서 기구부가 가지고 있는 고유진동 주파수에 의해 동력 전달 부분에 있어 기계계의 응답 특성은 불안정해지고, 떨림 현상이 발생된다. 본 논문에서는 PMSM을 이용한 회전 운동 시스템에서 출력되는 전류에 기구부가 가지고 있는 특정 영역의 고유진동 주파수를 제거한 전류를 적응 노치필터를 통해 내보낸다. 그 결과 기계부의 떨림 현상을 제거하고, 안정적인 제어 시스템을 제안한다. 이 제어알고리즘을 가상실험으로 필터 통과 전과 후의 결과를 비교 및 분석하도록 한다.

  • PDF

The Effect of Exercise Behavior Change of Casino Securities on Their Physical Self-description (카지노 시큐리티 종사자의 운동행동변화과정이 신체적 자기개념에 미치는 효과)

  • Chun, Yong-Tae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.597-601
    • /
    • 2009
  • The purpose of this study is to closely examine the effect of exercise behavior change of casino securities on their physical self-description. This observation takes place in casino enterprises in Seoul, Busan, Kangwon and Jeju. Within these areas, we have selected companies with more than 30 securities. Among 450 persons sampling unit, we have excluded 77 copied which seem to be insincere, and actually used 373 copies in this study. Evaluation forms are used as a study method; each form consists of continuance 5 points Likert scales and nominal/proportional scaling and used after excluding a test through the analysis of validity and reliability. After encoding and inputting the framing completed data along with each purpose, it was computerized by computer process, making use of SPSS 15.0 version. Through the data analysis according to these methods and procedures, the result on this study is described below. First, the exercise behavior according to socio-demographic characteristics. Second, the decision-making balance according to socio-demographic characteristics. Third, the self-efficacy according to socio-demographic characteristics. Fourth, the physical self-concept according to socio-demographic characteristics. Fifth, the exercise behavior influence indirectly on the physical self-concept throughout the decision-making balance and self-efficacy.

  • PDF

Analysis of a fixed source-to-receiver underwater acoustic communication channel parameters in shallow water (송수신기가 고정된 천해 수중음향통신 채널 매개변수 해석)

  • Bae, Minja;Park, Jihyun;Yoon, Jong Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.5
    • /
    • pp.494-510
    • /
    • 2019
  • Underwater acoustic communication channel parameters consist of impulse response, delay spreading, scattering function, coherence bandwidth, frequency selective fading, coherence time and time variant magnitude fading statistics on which communication system modem and channel coding are designed. These parameters are influenced by sound velocity profile, platform motion and sea surface roughness in given acoustical oceanography condition. In this paper, channel model based on phasor, channel simulator, measurement and analysis method of channel parameters are given in a fixed source-to-receiver system and the parameters are analyzed using shallow water experimental data. For two different source-to-receiver ranges of 300 m and 600 m, the parameters are characterized by three multipaths such as a direct, a surface reflection path with time variant scattering and a bottom reflection path. The results present a channel modelling method of a fixed source source-to-receiver system, channel parameters measurement and analysis methods and a system design and performance assessment method in shallow water.

Shake Table Response and Analysis of RC Bridge Piers with Lap-Spliced Steel under NFGM (주철근 겹침이음된 RC교각의 근단층지반운동에 대한 진동대 응답과 분석)

  • Chung, Young-Soo;Park, Chang-Young;Hong, Hyun-Ki;Park, Ji-Ho;Shim, Chang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.451-458
    • /
    • 2008
  • The near-fault ground motion (NFGM) is characterized by a single long period velocity pulse of large magnitude. NFGM's have been observed in recent strong earthquakes, Izmit Turkey (1999), Kobe Japan (1995), Northridge USA (1994), etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the near-fault ground motion (NFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this study is to investigate and analyze the effect of near-fault ground motions on reinforced concrete (RC) bridge piers with lap-spliced longitudinal reinforcing steels. The seismic performance of four RC bridge piers under near-fault ground motions was investigated on the shake table. In addition, a RC bridge pier is subjected to pseudo-dynamic loadings. Test results showed that large residual displacements were observed in RC bridge piers under NFGM. RC specimens on the shake table failed at relatively low displacement ductility, compared with the displacement ductility of RC bridge pier subjected to pseudo-dynamic loadings.