• Title/Summary/Keyword: 용적분석

Search Result 618, Processing Time 0.029 seconds

Prostate Volume Measurement by Transrectal Ultrasonography in the Healthy Korean Men in Thirties (건강한 30대 한국인 남성에서 경직장초음파를 이용한 전립선 용적 측정)

  • Kim, Yon-Min;Jeong, Jeong-Yun;Han, Dong-Kyoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.338-345
    • /
    • 2012
  • Benign prostatic hyperplasia (BPH) is increasing in Korea owing to the westernized eating habits and changes in living environment. However, very few studies have been made to determine the standard value of the prostate volume as a diagnostic reference. Also, most of the previous studies have been focusing on the elder population over 40 years old. This study retrospectively analyzes the results of prostate volume measured by transrectal ultrasonography in the healthy Korean men in their 30's who visited our institution's center for health promotion for routine checkups. The mean age of the total of 157 men enrolled was $34.6{\pm}2.9$ years, and the mean prostate volume was $19.4{\pm}4.0ml$. Prostate volume of these men was correlates proportionally to their age, prostate specific antigen, body mass index, body surface area, and abdominal girth. Among these, the strongest correlation is between the prostate volume and the abdominal girth (r=0.317, p<0.001).

The effect of patient position on dose in radiation therapy of liver cancer (환자 자세가 간의 방사선 치료 시 선량에 미치는 영향)

  • Jung, Won Seok;Kim, Ju Ho;Kim, Young Jae;Shin, Ryung Mi;Oh, Jeong Hun;Jeong, Geon A;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Purpose : To analyze tumor's movement and volume change from changing position in order to minimize movement caused by breathing. Materials and Methods : We conducted survey of 14 patients with HCC(Hepatocellular carcinoma). Patient immobilization device was made in two ways(Supine position, prone position) and from image acquisition, tumor's movement, volume and dose are analyzed. Results : The mean movement of target(LR, Left-right) in supine position and prone position was $2.76{\pm}1.25mm$, $2.21{\pm}0.93mm$. AP(Anterior-posterior) and SI(Superior-inferior) was $4.02{\pm}1.63mm$, $11.56{\pm}3.08mm$, $3.36{\pm}1.17mm$, $7.45{\pm}1.96mm$. Treatment volume was decreased and normal liver volume was increased in prone position. Conclusion : We could reduce the margin of the treatment volume by minimizing the movement of liver caused by breathing. Especially in prone position, it is considered to be able to decrease the movement of the liver and increase normal liver volume.

Analysis of Economical Benefit in Close-to-Nature Stream Using Contingent Valuation Method (조건부가치평가법을 이용한 자연형 하천의 경제적 편익 분석)

  • Kim, Souk-Gyu;Kim, Chul;Lee, Chang-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.517-522
    • /
    • 2005
  • 자연형 하천은 사용가치 뿐만 아니라 비사용적 가치를 포함하고 있기 때문에 비용편익분석에 비사용적 가치를 포함시켜야 한다. 그러지 못할 경우, 자연형 하천이 경제적 편익을 제공함에도 불구하고 경제적으로 타당성이 없는 것으로 판단될 수 있다. 본 연구는 자연형 하천의 경제적 편익을 분석하기 위하여 조건부가치평가법(CVM)을 이용하여 자연형 하천으로 조성된 전라북도 순창에 위치한 경천에 대하여 경제적 편익을 분석하였다. 연구방법은 가상적인 상황을 설정하고 여러 조건을 달아 자연형 하천에 대해 어느 정도 지불할 의사가 있는지를 설문을 통하여 분석하였다. 설문은 기본적인 속성과 환경용수, 생태계, 하천유지, 수질개선으로 구분하였고 순창읍 주민들을 대상으로 하였다. 자연형 하천으로 정비된 경천에 대해 경제적 편익을 분석한 결과 년간 약 11억원의 편익이 발생하는 것으로 추정되었다. 이와같은 결과를 이용하면 자연 친화적인 하천 정비사업을 시행할 때 합리적인 경제적 편익을 평가할 수 있으므로 사업의 타당성 평가에 이용할 수 있다.

  • PDF

Correlation between the Factors of Soil Physical Property in Upland Soil (밭작물 토양물리성 지표관련 인자의 상관분석)

  • Kim, Chan-Yong;Seo, Young-Jin;Kwon, Tae-Young;Park, Jun-Hong;Heo, Min-Soon;Ha, Sang-Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.793-797
    • /
    • 2010
  • The investigations were conducted to improve the physical properties by analyzing physico-chemical properties on the different soil families of textures at 20 upland fields located in the parts of Gyengsangbuk-do area. Soil physico-chemical properties were analyzed for bulk density, hardness, porosity, moisture, pH, EC and organic mater by soil depth on the different soil families of textures. Bulk density distributions were higher than 1.2 Mg $m^{-3}$ in the optimum range. Hardness distributions were lower than 20 mm in the optimum range. Therefore, the physical properties of upland soil was deteriorated. Correlation coefficient of bulk density with hardness and organic mater were higher significantly, that was positive and negative, respectively. The soil hardness had the greatest distribution degree to the crop yield and bulk density and organic matter followed. Conclusively, To improve the physical properties of upland soil was more effective to fertilizing organic matter than other ways.

A Study on Management Plans through Case Analysis of Residential Complexes in Commercial Areas in Daejeon (대전시 상업지역 주거복합건축물 사례 분석을 통한 관리방안 연구)

  • Ryu, Kyungsoo
    • Journal of the Korean Regional Science Association
    • /
    • v.39 no.2
    • /
    • pp.63-76
    • /
    • 2023
  • Recently, due to the location of residential complexes in commercial areas of large cities, the urban function is shifting from commercial to residential.In order to improve the use volume system in the commercial area of Daejeon Metropolitan City, the system of special and metropolitan cities was compared and analyzed, and problems were derived by analyzing 8 cases. First, use classification of mixed-residential buildings, Second, unbalance of urban planning for functional loss of commercial area, Thrid, damage on urban environment due to difference of development density. Accordingly, improvement measures include First, securing the ratio of residential function and mixed use at least 10%, Second, securing urban competitiveness by inducing facilities that combine various uses and functions. The overall floor area ratio of housing is applied, Third, the development density is presented through the establishment of the district unit plan and consultation.

Quantitative Indices of Small Heart According to Reconstruction Method of Myocardial Perfusion SPECT Using the 201Tl (201Tl을 이용한 심근관류 SPECT에서 재구성 방법에 따른 작은 용적 심장의 정량 지표 변화)

  • Kim, Sung Hwan;Ryu, Jae Kwang;Yoon, Soon Sang;Kim, Eun Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: Myocardial perfusion SPECT using $^{201}Tl$ is an important method for viability of left ventricle and quantitative evaluation of cardiac function and now various reconstruction methods are used to improve the image quality. But in case of small sized heart, you should always be careful because of the Partial Volume Effect which may cause errors of quantitative indices at the reconstruction step. So, In this study, we compared those quantitative indices of left ventricle according to the reconstruction method of myocardial perfusion SPECT with the Echocardiography and verified the degree of the differences between them. Materials and Methods: Based on ESV 30 mL of Echocardiography, we divided 278 patients (male;98, female;188, Mean age;$65.5{\pm}11.1$) who visited the Asan medical center from February to September, 2012 into two categories; below the criteria to small sized heart, otherwise, normal or large sized heart. Filtered and output each case, we applied the method of FBP and OSEM to each of them, and calculated EDV, ESV and LVEF, and we conducted statistical processing through Repeated Measures ANOVA with indices that measured in Echocardiography. Results: In case of men and women, there were no significant difference in EDV between FBP and OSEM (p=0.053, p=0.098), but in case of Echocardiography, there were meaningful differences (p<0.001). The change of ESV especially women in small sized heard, significant differences has occurred among FBP, OSEM and Echocardiography. Also, in LVEF, there were no difference in men and women who have normal sized heart among FBP, OSEM and Echocardiography (p=0.375, p=0.969), but the women with small sized heart have showed significant differences (p<0.001). Conclusion: The change in quantitative indices of left ventricle between Nuclear cardiology image reconstruction, no difference has occurred in the patients with normal sized heart but based on ESV, under 30 mL of small sized heart, especially in female, there were significant differences in FBP, OSEM and Echocardiography. We found out that overestimated LVEF caused by PVE can be reduced in average by applying OSEM to all kinds of gamma camera, which are used in analyzing the differences.

  • PDF

The Change of the Structure of Green Space by the Change of the Floor Area Ratio in Apartment Complex (용적률 변화에 따른 공동주택 단지내 녹지구조 변화특성)

  • 김정호;이경재;김정호
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.1
    • /
    • pp.42-52
    • /
    • 2004
  • The purpose of this study was to propose the change of green area and green structure according to the change of the Floor Area Ratio(FAR) of apartment complex. The survey site was selected two each of apartment complex after due consider three type that is, the FAR below 100%, the FAR below 250% and the FAR over 250%. Green rate is 40.23~44.23%, green width is 3~15m, green volume is 1.06~1.71㎥/$m^2$, planting density of cannopy layer is 0.04~0.06tree/$m^2$, planting density of understory layer is 0.06~0.20tree/$m^2$ in case of Hwagok 2nd Jugong apartment(FAR 99%) and Gaepo Jugong apartment(FAR 73%) constructed in the 1970~1980. Green rate is 24.16~26.16%, green width is 3~7m, green volume is 0.84~1.54㎥/$m^2$, planting density of cannopy layer is 0.18~0.31tree/$m^2$, planting density of understory layer is 0.15~0.35tree/$m^2$ in case of Deungchon Jugong aparment(FAR 226%) and Gaehwa apartment(FAR240%) construsted in the mid-1990's. Green rate is 23.47~25.53%, green width is 2~6m, green volume is 1.06~2.12㎥/$m^2$, planting density of cannopy layer is 0.25tree/$m^2$, planting density of understory layer is 0.22~0.37tree/$m^2$ in case of Hanbo Guam apartment(FAR 269%) and Donga 3rd apartment(FAR 376%) constructed in the last-1990's. As the results of analysis of green structure according to changes of the Floor Area Ratio(FAR), the greater the FAR, the higher the rate of green area. The green volume and planted density is low without the change of the FAR and planted structure was simple-layer structure composed of alien woody species.

Estimating Development Density Constrained by Traffic Congestion in the Downtown, Seoul (교통혼잡을 고려한 서울 도심부 개발가능밀도 추정)

  • Hwang, Kee Yeon;Shin, Sang Young;Kang, Jun Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1D
    • /
    • pp.49-58
    • /
    • 2006
  • The purpose of this study is to develop transportation-sensitive land use densities in a metropolitan context. It analyses traffic impacts according to 20 different development density scenarios in the downtown Seoul, and estimates the density ceiling. The results identify that the transportation-wise sustainable density in the downtown can be extended up to the FAR level of 460% with an option of 2,000 won congestion charge levied on the downtown area. It also finds that the region-wide sustainability measured by congestion level can be improving as the level of congestion charge increases. Without the congestion charge, however, the density ceiling slides down to 430%. It is recommended that, in order to bring in higher density developments in the region, transportation demand management (TDM) measures are indispensible.

Analysis of the cause of dose delivery errors due to changes in abdominal gas volume during MRgART pancreatic cancer (췌장암 MRgART시 복부가스용적 변화에 의한 선량전달오류 원인 분석)

  • Ha, Min Yong;Son, Sang Jun;Kim, Chan Yong;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.73-83
    • /
    • 2020
  • Purpose: The purpose of this study is to confirm the matching of the electron density between tissue and gas due to variation of abdominal gas volume in MRgART (Magnetic Resonance-guided Adaptive Radiation Therapy) for pancreatic cancer patients, and to confirm the effect on the dose change and treatment time. Materials and Methods: We compared the PTV and OAR doses of the initial plan and the AGC(Abdominal gas correction) plans to one pancreatic cancer patient who treated with MRgART using the ViewRay MRIdian System (Viewray, USA) at this clinic. In the 4fx AGC plans, Beam ON(%) according to the patient's motion error was checked to confirm the effect of abdominal gas volume on treatment time. Results: Comparing the Initial plan with the average value of AGC plan, the dose difference was -7 to 0.1% in OAR and decreased by 0.16% on average, and in PTV, the dose decreased by 4.5% to 5.5% and decreased by 5.1% on average. In Adaptive treatment, as the abdominal gas volume increased, the Beam ON(%) decreased. Conclusion: Abdominal gas volume variation causes dose change due to inaccurate electron density matching between tissue and gas. In addition, if the abdominal gas volume increases, the Beam ON(%) decreases, and the treatment time may increase due to the motion error of the patient. Therefore, in MRgART, it is necessary to check the electron density matching and minimize the variability of the abdominal gas.

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF