• Title/Summary/Keyword: 요골

Search Result 245, Processing Time 0.022 seconds

Usefuless of Ultrasonography Examination in Radial Nerve Palsy Associated with Humerus Fracture - Technical Report - (상완골 골절에 동반된 요골 신경 마비 환자에서 초음파 검사의 유용성 - 술기 보고 -)

  • Lee, Sang-Hyuk;Sung, Chang-Min;Park, Hyung-Bin
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Primary radial nerve palsy occurs in association with approximately 10% of humerus shaft fractures. Secondary radial nerve palsy, which is iatrogenic, occurs in association with approximately 10% to 20% of humerus shaft fractures. Whether the radial nerve palsy is caused primarily by the fracture or secondarily by the surgery, it is necessary to determine whether the radial nerve is being disrupted or compressed by the surrounding structures. This evaluation will dictate whether to await natural recovery or to perform surgical exploration. The current authors report one case of primary radial nerve palsy, due to the humerus fracture, and one case of secondary radial nerve palsy, associated with the osteosynthesis procedure. In both patients, the radial nerve was assessed for anatomical integrity with ultrasonography. Nerve disruption was found in one patient, and a sural nerve graft was performed. Nerve adhesion was found in the other patient, and neurolysis was performed. In both cases, the clinical results were satisfactory. This report focuses on the usefulness of ultrasonography in radial nerve assessment in patients with radial nerve palsy.

  • PDF

The Tangential Projection Method for Checking Existence and Nonexistence of Radius Groove Penetration of Screw after Distal Radius Fracture Operation Used the T-type Plate (T형 금속판을 이용한 요골 원위부 골절 수술 후 나사못의 요골구 관통 유무를 확인하기 위한 접선방향 촬영법)

  • Seo, Sun-Youl;Hong, Ki-Jang;Han, Man-Seok;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.335-340
    • /
    • 2010
  • This paper is about a projection method to check existence of radius groove penetration of screw after distal radius fracture operation using the T-type plate. Angle of Radius groove was analyzed by fifty one CT images that contains patients' wrist and twenty cases of radius specimens. After making radius phantom by plaster, we set the screw so that it penetrated 2.4 mm depth of radius groove. Then, we projected the phantom by X-ray in change of the elevation and supination angle of distal radius by 5 degree interval on 0~30 degree. The average value of groove angle in the wrist CT images was 14.4 degree and the radius specimens was 16.3 degree. Screws penetrating radius groove of the phantom have different lengths according to elevation angle and supination angle. Consequently, in order to confirm existence and nonexistence of radius groove penetration of the screw in tangential projection after distal radius fracture operation using the T-type plate, we recommend 5 degree of elevation angle and 20 degree of supination angle.

Harvesting of Radial Artery With Harmonic Scalpel (Harmonic Scalpel을 이용한 요골동맥의 적출)

  • 이현성;강정한;최성실;장병철
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.499-501
    • /
    • 2001
  • In the 1970s, the radial artery was proposed as a coronary artery bypass graft but then was abandoned due to graft occlusion secondary to spasm during harvesting. Development of new pharmacologic antispasmodic agents and minimal traumatic harvesting techniques has led to the revival of the use of the radial artery in coronary artery bypass procedures. Harmonic Scalpel(Ultracision Inc, Smithfield, Rl) offers the surgeon the ability to perform less traumatic, spasm free, and rapid radial artery harvesting.

  • PDF

Superficial Radial Neuropathy due to Anatomic Variation: A Case Report (해부학적 변이로 인한 표재성 요골 신경병증: 증례 보고)

  • Changwon Choi;Hye Jung Choo
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.468-473
    • /
    • 2024
  • Superficial radial neuropathy is a purely sensory neuropathy, usually caused by nerve entrapment in the distal forearm. We report a case of superficial radial neuropathy caused by the anomalous course of the superficial radial nerve, which was found to be spirally encircling the brachioradialis tendon in the distal forearm. To the best of our knowledge, this is the first report of an anatomical variant of the superficial radial nerve that causes neuropathy.

Early Result of Coronary Artery Bypass Grafting Using the Radial Artery (요골동맥를 이용한 관상동맥우회술의 조기성적)

  • 박진홍;지현근;신윤철;김응중
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.734-740
    • /
    • 2003
  • Increasing interest in the use of arterial conduits is based on the better patency of left internal thoracic artery (LITA) than that of saphenous vein (SV) graft and radial artery (RA) is emerging as one of them. We compared the early result of coronary artery bypass grafting (CABG) using UTA and RA (RA group) with CABG using UTA and SV only (SV group). Material and Method: We compared the early operative results of 45 cases in RA group with 45 cases in SV group selected from 165 cases who had CABG between January 2000 and December 2002. The two groups had similar profiles of age, sex, NYHA functional class, left ventricular ejection fraction and coronary angiographic anatomy. We analysed each group on the preoperative risk factors and operative results. Result: There were no statically signigicant difference between groups in operative mortality and each morbidities (stroke, IABP insertion, perioperative MI), respectively. However, the overall incidence of mortality and morbidities was lower in RA group compared to SV group (p < 0.05). RA group (2.93$\pm$0.62 days) had shorter duration of ICU stay than SV group (3.55$\pm$0.95 days) (p<0.001). The patency on postoperative coronary angiography at 7∼14 days after operation in RA group patients were 100% of LITA and RA and 94.9% of SV. Conclusion: We had better early operative results in RA group compared with SV group.

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

Ultrasonography in Radial Nerve Palsy after Surgery of Humerus Shaft Fracture - Case Report - (상완골 간부 골절 수술 후 발생한 요골신경 마비에서 시행한 초음파 검사 -증례 보고-)

  • Yoon, Hyungmoon;Kho, Dukhwan;Kim, Hyeungjune;Nam, Kyoungmo;Kang, Daemyung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.106-112
    • /
    • 2012
  • Radial nerve palsy after surgery of humerus fracture is uncommon complication. Occasionally it needs operative treatment because of difficulty to accurate evaluation. We report this case of radial nerve palsy after surgery of humerus shaft fracture with ultrasound examination. We checked the continuity of radial nerve and radial nerve palsy was complete recovered with conservative treatment.

  • PDF

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.

Acute Rupture of Extensor Pollicis Longus Tendon after Distal Radius Fracture: A Case Report (요골 원위부 골절 후 발생한 급성 장무지 신전건 파열 -1예 보고-)

  • Hwang, Jung Chul;Chung, Duke Whan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.24-27
    • /
    • 2011
  • Late rupture of the extensor pollicis longus (EPL) tendon is an occasional complication following a distal radius fracture. Early rupture of the EPL tendon as a complication of distal radius fracture is rare. We report one case of early rupture of the EPL tendon after distal radius fracture.

  • PDF