• Title/Summary/Keyword: 완전삭제

Search Result 54, Processing Time 0.021 seconds

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

Study on the personal Information Retrieval of Smartphone Messenger Service (스마트폰 메신저 어플리케이션에서의 개인정보보호에 관한 연구)

  • Kang, Sunghoon;Kim, Seungjoo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.1
    • /
    • pp.97-107
    • /
    • 2013
  • The recent increase in smartphone usage has ignited the development of new applications which have changed the way of living in this internet era in the world. Almost all users which have smartphone have used many kinds of applications for lots of part. Especially, Social Network Service is the most popular part for smartphone users. The greater part of smartphone users take messenger service for smartphone. This kinds of applications provide to manage as deactivation of user or change of device. When users take to manage their information, their information would be deleted securely. If secure deletion didn't work correctly and released, their personal information can be easily abused to by others through various means such as internet phishing. In this paper, we analysis that the messenger application's management function keeps on the Personal Information Protection Act and suggest to prevent legally and technically for user's personal information and privacy.

A 3-SAT Polynomial Time Algorithm Based on Minimum Frequency Literal-First Selection Method (최소 빈도수 문자 우선 선택 방법의 3-SAT 다항시간 알고리즘)

  • Sang-Un, Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.1
    • /
    • pp.157-162
    • /
    • 2023
  • To NP-complete 3-SAT problem, this paper proposes a O(nm) polynomial time algorithm, where n is the number of literals and m is the total frequency of all literals in equation f. The algorithm firstly decides a truth value of a literal in sequence of previously-set priority. The priority order is as follows: a literal whose occurrence in a clause is 1(k=1), a literal which is k≥2 and whose truth value is either 0 or 1, and a literal with the minimum frequency. Then, literals whose truth value is determined are then deleted from clause T and the remaining clauses. This process is repeated l times, the number of literals. As a result, the proposed algorithm has been successful in accurately determining the satisfiability of a given equation f and in deciding the truth value of all the literals. This paper, therefore, provides not only a linear-time algorithm as a viable solution to the SAT problem, but also a basis for solving the P versus NP problem.

k-SAT Problem Algorithm Based on Maximum-Maximum Frequency (최대-최대 빈도수 k-SAT 알고리즘)

  • Sang-Un Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.125-132
    • /
    • 2023
  • To NP-complete 3-SAT problem, this paper proposes a O(nm) polynomial time algorithm, where n is the number of literals and m is the total frequency of all literals in equation f. Conventionally well-known DPLLs should perform O(2𝑙) in the worst case by performing backtracking if they fail to find a solution in a brute-force search of a branch-and-bound for the number of literals 𝑙. DPLL forms the core of the SAT Solver by substituting true(T) or false(F) for a literal so that a clause containing the least frequency literal is true(T) and removing a clause containing that literal. Contrary to DPLL, the proposed algorithm selects a literal max𝑙 with the maximum frequency and sets $_{\max}({\mid}l{\mid},{\mid}{\bar{l}}{\mid})=1$. It then deletes 𝑙∈ci clause in addition to ${\bar{l}}$ from ${\bar{l}}{\in}c_i$ clause. Its test results on various k-SAT problems not only show that it performs less than existing DPLL algorithm, but prove its simplicity in satisfiability verification.

A Study on the Fatigue Characteristics in Butt-Welded Joints with Incomplete Penetration (용입부족을 가진 횡방향 맞대기 용접부의 피로특성에 관한 연구)

  • Chang, Dong Il;Kyung, Kab Soo;Hong, Sung Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.497-508
    • /
    • 1998
  • The objective of this study is to examine fatigue behavior of as-welded butt-welded joints with incomplete penetration from fatigue tests. The test results are the following. In static tests, tensile strength and yield strength of butt-welded joints are constant regardless of incomplete penetration. And in fatigue tests, fatigue strength of fully penetrated butt-welded joints satisfies fatigue limits, prescribed in Korean Specifications and JSSC, respectively. The results show that as the magnitude of incomplete penetration increases, fatigue strength decreases. In fractured surfaces, full and incomplete penetration specimen show different shapes, it is because that stress concentration factor vary with structural geometry in bead toe and root tip, and certify in FEM analysis. This study suggests that defects such as incomplete penetration from welding must be avoided in order to attain the sufficient life of steel structures.

  • PDF

Comparison of GEE Estimators Using Imputation Methods (대체방법별 GEE추정량 비교)

  • 김동욱;노영화
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.2
    • /
    • pp.407-426
    • /
    • 2003
  • We consider the missing covariates problem in generalized estimating equations(GEE) model. If the covariate is partially missing, GEE can not be calculated. In this paper, we study the performance of 7 imputation methods to handle missing covariates in GEE models, and the properties of GEE estimators are investigated after missing covariates are imputed for ordinal data of repeated measurements. The 7 imputation methods include i) Naive Deletion ii) Sample Average Imputation iii) Row Average Imputation iv) Cross-wave Regression Imputation v) Carry-over Imputation vi) Bayesian Bootstrap vii) Approximate Bayesian Bootstrap. A Monte-Carlo simulation is used to compare the performance of these methods. For the missing mechanism generating the missing data, we assume ignorable nonresponse. Furthermore, we generate missing covariates with or without considering wave nonresp onse patterns.

Esthetic restoration of malpositioned anterior teeth by tooth shape and gingival contour modification : a clinical report (위치이상 치아의 치은 성형을 동반한 심미적 보철수복)

  • Kim, Ja-Yeong;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.143-149
    • /
    • 2015
  • In esthetic treatments, it is important to consider the arrangement of teeth and the relation between the teeth and soft tissues. A precise diagnosis and establishing an appropriate treatment plan is essential in an esthetic treatment of anterior maxillary teeth. For a fixed prosthesis to meet esthetic expectations, It is crucial to achieve symmetry and adequate proportions of the gingival contour around the crowns. To achieve an esthetic improvement and creating a favorable environment for gingival healing of a physiologic gingival contour, gingivectomy, crown lengthening and forced eruption can be applied to the appropriate site. All ceramics or porcelain laminate veneer can be selected for esthetic improvement of teeth contour and shade. In this case report, malposition of the remaining teeth made it hard to get an esthetic appearance. Gingivectomy, crown lengthening and provisional restoration insertion were performed before the final prosthesis fabrication to reform the gingival form. This case presents satisfying result esthetically and functionally.

A Study on Extracting the Document Text for Unallocated Areas of Data Fragments (비할당 영역 데이터 파편의 문서 텍스트 추출 방안에 관한 연구)

  • Yoo, Byeong-Yeong;Park, Jung-Heum;Bang, Je-Wan;Lee, Sang-Jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.43-51
    • /
    • 2010
  • It is meaningful to investigate data in unallocated space because we can investigate the deleted data. Consecutively complete file recovery using the File Carving is possible in unallocated area, but noncontiguous or incomplete data recovery is impossible. Typically, the analysis of the data fragments are needed because they should contain large amounts of information. Microsoft Word, Excel, PowerPoint and PDF document file's text are stored using compression or specific document format. If the part of aforementioned document file was stored in unallocated data fragment, text extraction is possible using specific document format. In this paper, we suggest the method of extracting a particular document file text in unallocated data fragment.

The dimension analysis of prepared natural teeth for developing customized zirconia block (맞춤형 지르코니아 블락 제작을 위한 삭제된 치아의 평균 크기 분석)

  • Kim, Min-Hyuk;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.381-388
    • /
    • 2017
  • Purpose: Unpredictable shrinkage of zirconia during sintering process causes discrepancy. Therefore, there have been attempts to reduce discrepancy by milling zirconia after sintering. However, due to the hardness of sintered zirconia, milling takes longer time, causes damage to the machine and causes chip formation. With customized zirconia block using the mean dimension of prepared natural dentition, it is expected to overcome these shortcomings. Materials and methods: The mean dimension of prepared natural dentition was analyzed as STL file after scanning of prepared teeth treated at SNUDH. The transverse, frontal and sagittal planes were set using Mimics and Photoshop. 3D volume was projected on each plane, and the outer line was measured through external tangent line, and the inner line was measured through inflection point of tangent line. Results: The mean height of prepared incisal (N = 57) is $6.60{\pm}1.05mm$, mesiodistal length is $2.98{\pm}0.73mm$, buccolingual length is $2.04{\pm}0.73mm$. The mean height of prepared premolar (N = 15) is $5.37{\pm}1.49mm$, mesiodistal length is $4.10{\pm}1.78mm$, buccolingual length is $5.86{\pm}1.55mm$. And the mean height of prepared molar (N = 13) is $5.11{\pm}1.29mm$, mesiodistal length is $6.80{\pm}1.18mm$, buccolingual length is $7.34{\pm}1.40mm$. Conclusion: Using the mean dimension of prepared natural dentition, it is expected to be able to fabricate customized zirconia block.

EFFECT OF VARIOUS MECHANICAL TREATMENTS OF HYDROXYAPATITE-COATED IMPLANT SURFACES (Hydroxyapatite 피막 처리된 임프란트에 대한 여러가지 기계적 표면처리방법이 임프란트 표면조도 및 성상에 미치는 영향)

  • Yang, Kyung-Ran;Jung, Oh-Chul;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.131-143
    • /
    • 1994
  • For maintenance of exposed implant in healthy state, it is necessary to treat the surface of implant fixture and provide the surface adjustable to surrounding tissues. Variable techniques have been introduced such as citric acid and air-abrasive system to treat the failed implant. Although when the rough surface of HA coated implant was exposed to oral environment, the surface treatment method with citric acid or air-abrasive system is effective for removal of bacterial endotoxin, it is unsuccessful to prevent plaque deposition due to difficulty in removal of rough surface of HA coated implant. Thus, in this study the method that removes bacterial endotoxin and makes smooch surface without alteration of surface characteristics was studied. HA coated disc manufactured by IMZ Co. Was treated with high speed diamond bur, low speed diamond bur, stone bur, rubber point, jetpolisher. And then its surface state was examined with profilometer and SEM to evaluate the surface smoothness, and its surface component was analyzed with EDX to evaluate wheter the surface characteristics were altered or not. As a result, following results were obtained. When the surface roughness of each implant disc was measured by profilometer, the group I showed a $R_{max}\;2.11{\mu}m$ and the group II, III, IV, V showed a $R_{max2}\;4.17{\mu}m$, $7.28{\mu}m$, $8.61{\mu}m$ and $39.44{\mu}m$ respectively. That is, surface smoothness was highest in the group I and it has been gradually decreased in the group II, III, IV and V. Under the SEM examination, the group I showed relatively smooth surface and the group II showed slightly rougher surface than the group I due to partially remaining HA particles while most HA particle was removed. The group III and IV showed rough topography due to HA particles that was not grinded, and HA coated surface in group V showed very irregular surface with deep groove and prominence. In cross-sectional view, the group I showed uniform surface, and the group III, IV showed rough surface due to remaining HA particles but the thickness of HA coating was remarkably reduced. The group II has similar pattern in group I, and the group V showed about $40{\mu}m$ thickness although it was not constant. By analysis of surface component with EDX, the group II in which the grinding was effective showed a small quantity of calcium and phosphorous and the group III, IV, in which the grinding was incomplete showed calcium and phosphorus peak. In all experimental group, no other than titanium, aluminum, calcium, phosphorus was observed.

  • PDF