• Title/Summary/Keyword: 열 구동기

Search Result 132, Processing Time 0.037 seconds

Evaluation of Structural Safety of Linear Actuator for Flap Control of Aircraft (항공기 플랩 제어를 위한 선형 구동기의 구조 안전성 평가)

  • Kim, Dong-Hyeop;Kim, Sang-Woo
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.4
    • /
    • pp.66-73
    • /
    • 2019
  • The objective of this study was to evaluate the structural safety of the basic design for the linear actuator for the flap control of aircrafts. The kinetic behavior of the linear actuator was determined using the multi-body dynamics (MBD) analysis, and the contact force was calculated to be used as input data for the structural analysis based on the finite element analysis. In the structural analysis, the thermal and static behaviors of the linear actuator satisfying the designed velocity were examined, and the structural safety of the linear actuator evaluated. Moreover, the dynamic behaviors of the key components of the linear actuator were investigated by the modal analysis. The actuation rod linearly moved with about 5 mm/s when the motor operated at 225 rpm and the maximum contact force of 32.83 N occurred between two driving gears. Meanwhile, the structural analysis revealed that the maximum thermal and static stresses were 1.57% and 78% of the yield strength of steel, respectively, and they were in a safe range of the structure. In addition, the linear actuator for the basic design is stable to the resonance by avoiding the natural frequencies of the components.

Thermal and Flow Analysis of a Driving Controller for Active Destruction Protections (능동 파괴 방호 구동제어기의 열 유동 해석)

  • Ryu, Bong-Jo;Oh, Bu-Jin;Kim, Youngshik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.235-242
    • /
    • 2017
  • A driving controller for active destruction protections can be applied to machinery, aerospace and military fields. In particular, this controller can be used to track and attack enemy flying objects through the active control. It is important to ensure reliability of the driving controller since its operation should be kept with precision to the target point. The temperature of the environment where the driving controller is used is about -32 C ~ 50 C (241~323 ). Heat generated in the driving controller should be maintained below a certain threshold (85 C (358 )) to ensure reliability; therefore, the study and analysis of the heat flow characteristics in the driving controller are required. In this research, commercial software Solid-Works Flow Simulation was used for the numerical simulation assuming a low Reynolds number turbulence model and an incompressible viscous flow. The goal of this paper is to design the driving controller safely by analyzing the characteristics of the heat flow inside of the controller composed of chips or boards. Our analysis shows temperature distributions for boards and chips below a certain threshold.

Development & properties of 30W Linear Motor with Resonance Spring for Linear Actuator (30W 선형전동기를 이용한 공진구동형 액추에이터 제작과 특성)

  • Woo, Byung-Chul;Hong, Do-Kwan;Kim, Jong-Moo;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.744-745
    • /
    • 2008
  • IT기기, 통신시기, 반도체 기기 등은 점점 더 고성능화되면서 속도도 빨라지고 기능도 추가되는 추세이다. 이러한 IT기기들은 속도와 더불어 열문제는 더욱더 크게 강조되고 있는 실정이며 개인용으로 많이 사용하고 있는 PC의 경우 더 이상 속도를 높이지 못하고 있는 실정이다. 이러한 열문제는 100W까지는 Heat pipe 등으로 냉각이 가능하였으나 거의 한계수준에 도달한 상황이다. 이러한 상황에서 일부 메니아들은 빠른 속도의 통신이나 작업을 위해서 수냉식 전용 냉각기를 설치하여 현재의 기능보다 더 좋은 환경에서 사용하고자 하고 있다. 본 연구에서는 수냉식 냉각기보다 더 큰 열용량을 가진 CPU의 냉각을 위해서 냉매 압축기를 적용하고자 하였으며 냉매 압축기에 사용하기 위한 선형압축기를 개발하고자 하였다. 즉 선형압축기에 의해서 압축된 냉매를 사용하여 CPU를 냉각하기 위해서 본 연구를 시작하였다. 본 연구에서는 선형전동기를 공진구동형 스프링을 장착하여 50-100Hz로 공진구동하는 액추에이터를 제작하여 그 특성을 알아보았다. 먼저 제자과정과 제작후 추력과 공진구동 설계 및 공진구동시 전기적, 기계적 특성변화를 확인하였으며 피스톤과 실린더 및 흡입밸브와 배기밸브 등을 장착하여 선형압축기로서 시운전까지 수행하였다.

  • PDF

A Study on the Diagnosis and Failure Mode of AOV Actuators (공기구동밸브 구동기의 고장진단에 관한 연구)

  • Jeong, Gyeong-Yeol;Kim, Byeong-Deok;O, Sang-Hun
    • 연구논문집
    • /
    • s.34
    • /
    • pp.47-58
    • /
    • 2004
  • Power plants rely on air operated valves for the proper operation of many plant system. Many significant problems arise in vital systems of power plants due to air operated valve failures. This paper deals with the diagnosis technique and data acquisition method of an AOV actuator peformance. We constructed AOV diagnosis system and performed some tests to find out whether an AOV actuator was properly designed.

  • PDF

A Study on Thermal Analysis for Magnetostrictive Actuator Using Compressed Air Cooling (압축 공기 냉각을 이용한 자기 변형 구동기의 열해석에 관한 연구)

  • Kwak, Yong-Kil;Mostofa, G.;Hwang, Jin-Dong;Kim, Sun-Ho;Ahn, Jung-Hwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.388-394
    • /
    • 2009
  • Precision positioning system with magnetostrictive actuator(MA) has widely used in manufacturing devices to control the positioning accuracy to meet the high load and stroke requirements. It has many advantage in comparison with piezoelectic actuator; high force, high strain, high efficient etc. But, the performance of Terfenol-D, the commercially available magnetostrictive material, is highly dependent on the prestress, magnetic field intensity and temperature. Therefore, thermal strain of magnetostrictive material obstructs precision position control of magnetostrictive actuator, magnetostrictive actuator is need of cooling system. In this paper, cooling system using compressed cold air is developed and proper temperature and velocity of compressed cold air is studied by thermal analysis according to applied current.

  • PDF

건물공조용 CHP시스템의 흡착식 냉동기 적용

  • 박윤철
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.34 no.2
    • /
    • pp.28-32
    • /
    • 2005
  • 최근에 보급이 활성화되고 있는 CHP시스템을 건물공조용으로 이용할 경우에 필수적인 증기압축식 냉동기를 대체할 열구동 냉동기로써 흡착식 냉동기 기술을 언급하였다

  • PDF

태양열 구동 흡수식 냉방 시스템 실증

  • Gwak, Hui-Yeol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.353-362
    • /
    • 2005
  • 태양열시스템은 하절기에 급탕과 난방 부하가 적거나, 거의 없어 시스템의 과열 문제가 야기 될 수 있다. 이를 해결하는 방안 중에 하나로 흡수식 냉방시스템을 이용하여 하절기 잉여열원을 활용하여 냉방하는 방법이 대두되고 있다. 태양열 냉방시스템은 전기에너지를 대체하는 효과 뿐 아니라 태양열 연간 이용 효율 극대화에도 크게 기여 할 수 있다. 본 고에서는 국내 기술로 최초로 개발 실용화된 중온용 단일 진공관형 태양열 집열기와 1중 효용 흡수식 냉방기를 이용하여 실증연구를 계획하였다. 태양열 냉방 실증을 위하여 단일 진공관형 태양열 집열기 집열면적 200m2, 축열조(태양열, 급탕, 냉수), 10RT급 냉방기, 냉각탑, 보조 보일러, 원격 제어 및 모니터링 등이 계획 되었다. 실증시험 중간 결과 태양열 냉방시스템은 하절기 맑은 날 하루 동안 약 5 - 6시간 안정적으로 가동 되었으며, 앞으로 온수급탕, 난방 시험을 거쳐 시스템 성능 및 경제성 평가를 통하여 유용성, 안정성 및 신뢰성이 검증 될 계획이다.

  • PDF

Frequency and Position Dependences of Acoustically Driven Refrigerating Temperature Differences (음향구동 냉동 온도차의 주파수 및 위치 의존 특성)

  • 김용태;서상준;정성수;조문재
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.3-10
    • /
    • 1999
  • Investigations of temperature differences between both cnds of thermoacoustic exchanger generated by acoustic heat transport have been carried out as a function of the position of TAC(Thermo-Acoustic Couple)[1] in a 68-cm-long duct. Fixed with the electric power at 50W, measurements were compared with the theory changing the frequency from 150Hz to 300Hz with 10Hz step. The frequency-position dependent distribution of temperature difference corresponding to the Q-values was obtained with the numerical simulation. Through this distribution, the optimum position of the thermoacoustic exchanger and the optimum driving frequency can be determined.

  • PDF