• Title/Summary/Keyword: 연소시스템

Search Result 913, Processing Time 0.027 seconds

One Dimensional Analysis on Alcohol Burner Flow for Turbopump Operation (터보펌프 구동용 알코올버너 유동 일차원 해석)

  • Kim, Seong-Lyong;Wang, Seung-Won;Han, Young-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • TPTF (Turbopump Real Propellant Test Facility) at Naro Space Center has used alcohol burner system to simulate the gas flow of gas generator of liquid rocket engine. During the test at TPTF, the temperature and pressure at turbine inlet were smoothly increased while those of the gas generator of engine were constant. Present research developed a simulation code for the burner and the piping system and applied to the system. The calculation results were in good agreement with the test, and confirmed quantitatively that the non-steadiness is due to the heat transfer of the pipe. While the insulation of the pipe is ineffective, the length has a large impact on the turbine inlet condition. The present research clarified the empirically estimation of test condition, and can be applied to determination of the following test conditions.

Fuel Rich Gas O/F Ratio Characteristics of HDPE and Paraffin Fuel in Low Range of the Oxidizer Mass Flux (저 산화제유속 구간에서의 HDPE 및 Paraffin 연료의 연료농후가스 O/F비 특성)

  • Han, Seongjoo;Ryu, Sunghoon;Kim, Jinkon;Kang, Teagon;Moon, Heejang;Kim, Junhyung;Ko, Seung Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.6
    • /
    • pp.54-60
    • /
    • 2016
  • Multi-port HDPE and Paraffin firing tests are conducted for hybrid gas generator application of a ducted rocket in the low oxidizer mass flux range. A fuel rich gas of O/F ratio from 0.3 to 0.8, a typical O/F operating range of a ducted rocket gas generator, have been achieved with paraffin fuel implying that the hybrid system can be a potential candidate. It was also found that an almost constant O/F ratio regime exists under $35kg/m^2s$ of the oxidizer mass flux, opening a possibility for the paraffin fuel toward the VFDR gas generator application.

Crystallization of Hydrazinium Nitroformate(HNF) as Eco-friendly Oxidizer (친환경 산화제 HNF 결정화 연구)

  • Kim, Jina;Kim, Min Jun;Min, Byoung Sun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.6
    • /
    • pp.76-82
    • /
    • 2016
  • Recently, environmental sustainability of the transitional explosives and propellants is an issue of growing importance in energetic materials. For examples, ammonium perchlorate(AP) as an solid propellants oxidizer could create a poisonous gas and atmospheric pollutions, such as HCl. Among the several oxidizers, hydrazinium nitroformate(HNF) is an effective candidate substance for eco-friendly oxidizer, which has high density, pressure index, and less smog generating property during combustion for the thrust control system. This study was controlled the size distribution and shapes through various conditions. Length and diameter ratio(L/D) of crystals has below 1 : 3, and the particle size was two types of $200{\mu}m$ and $50{\mu}m$.

A Study on Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires (철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 연구)

  • Jang, Won-Cheol;Kim, Dong-Woon;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.3
    • /
    • pp.294-299
    • /
    • 2008
  • The present study investigates the ventilation effects on smoke spreading with the rescue stations. Experiments for tunnel fires were carried out for n-heptane pool em at different fire locations, and the heat release rates (HRR) were obtained by addition, using the commercial code (FLUENT), the present article presents numerical results for smoke behavior in railway tunnels with rescue station, and it uses the MVHS (Modified Volumetric Heat Source) model for estimation of combustion products resulting from the fire source determined from the HRR measurement. As a result, it is found that smoke propagation is prevented successfully by the fire doors located inside the cross-passages and especially, the smoke behavior in the accident tunnel can be controlled through the ventilation system because of substantial change in smoke flow direction in the cross-passages.

A Study on the Fire Risk Assessment and Prevention in the Recycling Process of Used Refrigerators (냉장고 파쇄 공정에서의 화재 위험성 및 예방에 관한 연구)

  • Lee, Su-Kyung;Song, Dong-Woo;Bae, Jeong-Ae
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.72-77
    • /
    • 2009
  • In the recycling procedure of the refrigerator, the fire frequently breaks out. In this study, to clarify the exact cause of the fire, the components and concentration of the materials produced in the process are analysed as well as the problems in the process system, and the protective measure to prevent the fire and the explosion fundamentally is proposed. In this procedure, the preventive measures of fire by removing the combustible materials such as polyurethane and inflammable gases, by removing the ignition sources and by reducing the oxygen concentration to the minimum are proposed along with the protective measures to reduce the damage in the fire. In the crushing procedure where the fire or explosion can break out in diverse ways, the forced ventilation or exhaust system applied to the small partial ventilation facility are installed to reduce the concentration of inflammable gas mixture to lower than the inflammable limit by injecting and exhausting the air forcibly.

Fine particulate Judgment based on Fuzzy Inference System (FUZZY 추론 시스템 기반 미세먼지 판단)

  • Hong, You-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.127-133
    • /
    • 2020
  • The international cancer research institute under the WHO designated fine dust as a first-class carcinogen. Particular matter refers to dust that is small enough to be invisible and floating in the air. Particular matter is mainly emitted from the combustion process of fossil fuels such as coal and oil, and is a risk factor that can cause lung disease, pneumonia, and heart disease. The Ministry of Environment recently analyzed the output data of 10 fine dust measuring stations and, as a result, announced that about 60% had an error that the existing atmospheric measurement concentration was higher. In order to accurately predict fine dust, the wind direction and measurement position must be corrected. In this paper, in order to solve these problems, fuzzy rules are used to solve these problems. In addition, in order to calculate the fine particulate sensation index actually felt by pedestrians on the street, a computer simulation experiment was conducted to calculate the fine particulate sensation index in consideration of weather conditions, temperature conditions, humidity conditions, and wind conditions.

A Study on the Determination of the Performance Correction Factors of Solid Rocket Motors (고체추진기관의 성능 보정계수 예측방법에 관한 연구)

  • 성홍계;변종렬;김윤곤
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.57-66
    • /
    • 2001
  • The precise prediction of the performance is essential to develope the system at the development of propulsion system since no experimental data are available. The accuracy of 1on the total system's performance as well as itself, which depends on how the correction fac $I_{sp}$, and so on, are determined in accurate. However some of the design factors are dete engineer's experience or the similar test data if they are available, so far. This study was the method of the determination of correction factors of both $I_{sp}$ and thrust in direct. The bas is to define the detail performance loss mechanism of solid rocket motors, might be occurre and to calculate in quantitative those correction factors from the performance loss mechanism the test results, the model of this study can predict those factors less than 1% error, in additi physical variances of each loss mechanism.

  • PDF

Noise Reduction of Electric Vehicle using Passive Damping Material (수동형 패치를 이용한 전기차 소음 저감)

  • Kim, Hyunsu;Kim, Byeongil;Han, Won-ok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.117-122
    • /
    • 2017
  • Cabin noise due to the electric powertrain of electrical vehicle may consists of motor noise caused by electrical mismatch and gear noise coming from reduction gearbox. These sound may be considered rather small noise compared to those of internal combustion engine, but without masking effect, the noise can be more annoying for customer. Thus, this paper demonstrates the characteristics of electrical vehicle powertrain noise, and the effect of passive damping material for the noise reduction. The typical motor noise can be affected by the motor torque. Also, it is demonstrated that the reduction gearbox may be a weak point for the noise path compared to the motor housing. With vehicle test, it is shown that the damping patch is more effective for noise reduction with deceleration condition than with acceleration condition.

Applicability of Climate Change Impact Assessment Models to Korean Forest (산림에 대한 기후변화 영향평가 모형의 국내 적용성 분석)

  • Kim, Su-na;Lee, Woo-Kyun;Son, Yowhan;Cho, Yongsung;Lee, Mi-Sun
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.1
    • /
    • pp.33-48
    • /
    • 2009
  • Forests store carbon dioxide ($CO_2$), one of the major factors of global warming, in vegetation and soils through photosynthesis process. In addition, woods deposit $CO_2$ for a long term until the harvested wood is decomposed or burned, and deforested areas could be expanded the carbon sinks through reforestation. Forests are a lso able to decrease temperature through transpiration and contribute to control the micro climate in global climate systems. Consequently, forests are considered as one of major sinks of greenhouse gases for mitigating global warming. It is very important to develop a Korea specific forest carbon flux model for preparing adaptation measures to climate change. In this study, we compared the climate change impact models in forests developed in foreign countries and analyzed the applicability of the models to Korean forest. Also we selected models applicable to Korean forest and suggested approaches for developing Korean specific model.

A Study on the safety measures for the protection of hydrogen cooling system of generator (수소를 냉각매체로 하는 발전기 안전대책에 관한 연구)

  • Lee Choon-Ha;Yuk Hyun-Dai
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.55-61
    • /
    • 2004
  • This paper provided a counter measures against the troubles and accidents that are likely to take place in the power plant using hydrogen gas as a coolant for the cooling system of the generator. Because of the extremely wide flammability limits of hydrogen in comparison to the other flammable gases, the safety measures against the hydrogen accidents is very important to ensure the normal operation of electric-power facility. This study's purpose was a presentation of standard model of safety management of hydrogen equipments in the coal firing power plant such as following items: 1) providing the technical prevention manual of the hydrogen explosions and hydrogen fires occurring in the cooling system of power generator; 2) the selection of explosion-proof equipments in terms of the risk level of operating environment; 3) the establishment of regulations and counter measures, such as the incorporation of gas leakage alarm device, for preventing the accidents from arising, 4) the establishment of safety management system to ensure the normal operation of the power plant.

  • PDF