• Title/Summary/Keyword: 여과지

Search Result 427, Processing Time 0.032 seconds

Biotransforamtion of inorganic nitrogens in soil of near bank filtration sites using respirometer (호흡량에 기준한 강둑여과지 주변 표층토의 무기질소 변환)

  • 공인철;배진희;최은영;김승현
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.35-43
    • /
    • 1999
  • Biotransformation of inorganic nitrogens, which are possible contaminants of bank filtered water, in soil of near bank filtration site was investigated based on oxygen consumption and changes of chemical parameters in respirometer. Biotransformation activities of inorganic nitrogens at different conditions of pH. water content. and added initial${NH_4}_2$$SO_4$were compared. At original low pH and 20% of water content, nearly no biotransformation activity of inorganic nitrogen was observed, in addition, control and NH$_4$-added sets did not show any significant differences of oxygen consumption. Among tested conditions, the highest activity was observed at 25% water content and pH 8. Nearly 98% nitrification activity was observed at sets amended with 400 mg $NH_4$-N/kg soil as${NH_4}_2$$SO_4$in the condition of pH 8 and 20~23% water content. However, considerable activity of subsequent denitrification was not observed.

  • PDF

A Collaborative Recommendation Method based on Fuzzy Associative Memory (퍼지연상기억장치에 기반한 협력 추천 방법)

  • 이동섭;고일주;김계영
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.8
    • /
    • pp.1054-1061
    • /
    • 2004
  • At recent, people can easily access to information by Internet to be rapidly evolving. And also, the amount is rapidly increasing. So the techniques, to automatically extract the required information are very important to reduce the time and the effort for retrieving information. In this paper, we describe a collaborative filtering system for automatically recommending high-quality information to users with similar interests on arbitrarily narrow information domains. It asks a user to rate a gauge set of items. It then evaluates the user's rates and suggests a recommendation set of items. We interpret the process of evaluation as an inference mechanism that maps a gauge set to a recommendation set. We accomplish the mapping with FAM (Fuzzy Associative Memory). We implemented the suggested system in a Web server and tested its performance in the domain of retrieval of technical papers, especially in the field of information technologies. The experimental results show that it may provide reliable recommendations.

The Processing of Spatial Joins using a Bit-map Approximation (비트맵 근사 표현을 이용한 효율적인 공간 조인)

  • 홍남희;김희수
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.2
    • /
    • pp.157-164
    • /
    • 2001
  • This paper studies on the processing of spatial joins. The spatial join operation is divided into filters and refinement steps in general. The processing of spatial joins can be greatly improved by the use of filters that reduce the polygons in order to find the intersecting ones. As a result, three possible sets of answers are identified: the positive one, the negative one and the inconclusive one. To identify all the interesting pairs of polygons with inconclusive answers, it is necessary to have access to the representation of polygons so that an exact geometry test can take place. We introduce a bit-map approximation technique to drastically reduce the computation required by the refinement step during refinement processing. Bit-map representation are used for the description of the internal, the external and the boundary regions of the polygon objects. The proposed scheme increases the chance of trivial acceptance and rejection of data objects, and reduces unnecessary disk accesses in query processing. It has been shown that the reference to the object data file can be cut down by as much as 60%.

  • PDF

Filter-based Correction for Positive Sampling Artifacts in the Determination of Ambient Organic Carbon (여과지를 이용한 유기탄소의 측정 오차 보정)

  • Kang, Byung-Wook;Yeon, Ik-Jun;Cho, Byung-Yeol;Park, Sang-Chan;Lee, Hak-Sung;Jeon, Jun-Min;Na, Kwang-Sam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.63-72
    • /
    • 2011
  • This study describes the impact of positive sampling artifact caused by a filter-based sampling in the determination of ambient organic carbon (OC). Three different sampling media combinations were employed for this investigation: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), and (3) quartz filter and quartz filter behind Teflon filter (Q-QBT). The measurement of ambient OC was carried out at a semi-urban site near oceanside at the end of November of 2008. It was found that Q-alone sampling configuration resulted in a higher OC than QBQ and Q-QBT by 14% and 28%, respectively due to no correction for positive artifact caused by adsorption of gas-phase OC onto the filter. A lower quantity of OC was collected from the backup quartz filter on QBQ than that from Q-QBT. A possible explanation is that the front quartz filter of QBQ was not fully saturated with gas-phase OC during the sampling period, allowing smaller amount of gas-phase OC to reach the backup quartz filter. The contribution of positive artifact to $PM_{2.5}$ mass was approximately 2.15 ${\mu}g/m^3$ which is equivalent to 6% in terms of Q-QBT sampling configuration. The positive artifact was found to be more dominated during summer than during winter, showing temperature dependence. It was concluded that Q-QBT sampling configuration offers less impact of positive artifact on ambient OC sampling than QBQ in quantification of OC.

Development of an Evaluation Method for Flow Rate Performance of Particulate Sampling Pump using Three-pieces Cassette Holder Containing Filters (여과지가 장착된 3단 카세트를 이용한 입자상물질 채취용 펌프의 유량성능 평가방법)

  • Song, Ho-June;Kim, Nam-Hee;Kim, Ki-Youn;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.348-355
    • /
    • 2013
  • Objectives: In working environment measurement, sampling is an important stage for obtaining reliable result as analysis. A personal air sampling pump is one of the most fundamental and important element in the work environment measurement, but it remains at the level of calibrating the flow rate of the pump before and after sampling. There is no checking whether the flow rate set at the initial stage would be hold during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of particulate sampling pump with three-pieces cassette holder containing filters commonly used to sample particulate. Materials and methods: We tested back pressure of particulate sampling pumps commonly used in Korea with three-pieces cassette holder containing various filters, and tried to find out the combination conditions of filters in accordance with back pressure required by ISO standard 13137. Results: We found out the matrix of sampling media such as three-pieces cassette holder containing filters applicable to the pressure drop required by the ISO standard for evaluating the flow rate stability under increasing pressure drop and long term(8 hour) performance. Conclusions: This evaluation method using sampling media matrix for checking flow rate stability proposed by this study could be very useful tool to find out good performance pumps before sampling.

Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction (PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가)

  • 신용철;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

Design and Implementation of the Notification System based on the Event-Profile Model (이벤트-프로파일 모델을 기반으로 한 통지 시스템의 설계 및 구현)

  • Ban, Chae-Hoon;Kim, Dong-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1750-1755
    • /
    • 2011
  • Recently, it is possible for users to acquire necessary data easily as the various schemes of the searching information are developed. Since these data rise continuously like stream data, it is required to extract the appropriate data for the user's needs from the mass data on the internet. In the traditional scheme, they are acquired by processing the user queries after the occurred data are stored at a database. However, it is inefficient to process the user queries over the large volume of continuous data by using the traditional scheme. In this paper, we propose the Event-Profile Model to define the data occurrence on the internet as the events and the user's requirements as the profiles. We also propose and implement the filtering scheme to process the events and the profiles efficiently. We evaluate the performance of the proposed scheme and our experiments show that the new scheme outperforms the other on various dataset.

ITER HCCR TBM 헬륨냉각계통 개발을 위한 헬륨공급장치 구축 및 실험계획

  • Lee, Eo-Hwak;Kim, Seok-Gwon;Jin, Hyeong-Gon;Yun, Jae-Seong;Jo, Seung-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.465-465
    • /
    • 2014
  • 증식블랑켓모듈(TBM, Test Blanket Module)을 개발하여 왔다. 이 두 증식블랑켓모듈은 모두 헬륨냉각을 기반으로 개발 되어왔으며 이에 따라, 헬륨순환기, 헬륨히터 및 헬륨열교환기 등에 대한 기본적인 연구가 수행되었다. 이후 2012년 고체형 증식블랑켓모듈을 ITER TBM 개념으로 주도하기로 결정함에 따라, HCCR (Helium Cooled Ceramic Reflector) TBM의 보조계통인 하나인 헬륨냉각계통(HCS, Helium Cooling System)에 대한 개발이 본격적으로 이루어졌다. 한국원자력연구원에서는 HCCR TBM의 냉각성능을 만족하기 위하여 8 MPa, 1.5 kg/s 및 $300/500^{\circ}C$ (입구/출구 온도)의 운전조건을 갖는 헬륨냉각계통의 설계를 완료하였다. 설계된 헬륨냉각계통은 HCCR TBM에서 회수된 약 $450^{\circ}C$의 헬륨을 열회수기(recuperator)기와 냉각기를 통해 상온으로 냉각시킨 후, 필터를 통해 헬륨을 여과시킨다. 여과된 헬륨은 헬륨순환기에 의해 가압되어 열회수기를 다시 지나 $300^{\circ}C$ 이상으로 가열된다. 가열된 헬륨은 열회수기를 지나지 않는 상온의 헬륨과 혼합되어 최종적으로 HCCR TBM의 입구온도 조건인 $300^{\circ}C$로 맞추어 HCCR TBM에 공급된다. 이러한 열회수기 중심으로 '${\infty}$' 모양의 자가 교차로 설계된 헬륨냉각계통은 고온영역과 저온영역으로 냉각회로를 구분하여 순환기, 필터 및 각종 계측기의 운전온도 환경을 상온으로 유지시킬 수 있어 운전 및 유지보수 관점에서 이점이 있다. HCCR TBM의 헬륨냉각계통 설계 및 핵심 기기를 실증하고, 운전 경험을 쌓기 위하여 헬륨공급장치(HeSS, Helium Supply System)를 헬륨유량기준 1/3 규모(0.5 kg/s)로 구축하였으며, '14년까지 HeSS를 실증규모로 업그레이드 하기 위하여 80기압 환경에서 압축비 1.1, 유량 1.5 kg/s의 성능을 내는 헬륨순환기를 설치할 예정이다. 현재 구축된 1/3 규모 HeSS는 국내 구축된 전자빔 고열부하 시험 장비인 KoHLT-EB (Electron Beam)와 연계되어 HCCR TBM의 일차벽(플라즈마 대향부품)을 검증할 예정이며, 이를 통해 얻어진 열수력 DB는 현재 개발중인 핵융합로 안전해석코드인 GAMMA-FR 검증에 활용될 계획이다.

  • PDF

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Comparison of Nitrate and Fluoride Removals between Reverse-Osmosis, Nano-Flitration, Electro-Adsorption, Elecero-Coagulation in Small Water Treatment Plants (소규모 수도시설의 역삼투(RO), 나노여과(NF), 전기흡착(EA), 전기응집(EC) 공정의 질산성 질소 및 불소 이온 제거 성능 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2027-2036
    • /
    • 2013
  • Comparison of removal performance between reverse osmosis(RO), nanofiltration(NF), electrocoagulation(EC) and electroadsorption(EA) for removal of nitrate and fluoride often exceeded the limits of water quality in small water treatment plants. Removals of nitrate and fluoride were 72-92% and 74-85% in RO, 5-15% and 1% in NF, 99% and 44% in EA equipped with MWCNT coated electrodes, 82% and 77% in EA equipped with Cu-MWCNT electrodes, and 11-46% and 69-99% in EC. Consequently, high removals of both ions were anticipated in RO. Effective removal of both ions are possible for EC, but great production of sludge is a big burden. EA equipped with the MWCNT electrodes showed a great fluctuation in removal efficiency, and electrode stability should be upgraded.