Abstract

There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Chest PA 검사 시 디지털 촬영에 대한 검사 조건 권고안은 마련되어 있지 않다. 각 기기 회사들도 이전의 아날로그 촬영에 적용되었던 고관전압 촬영 조건을 권고하고 있다. 디지털 흉부 X-선 촬영시 관전압, 관전류, 부가여과 필터 변화에 따른 피폭선량을 비교하기 위해 Philips 사에서 권고하는 적정 노출지수( Expos ure Index ) 값인 200 ~ 800사이 값을 만족하는 검사조건을 선별하였다. 유효선량을 평가하기 위해 몬테카를로 시뮬레이션을 시행하였으며 SNR과 CNR을 측정하여 영상평가를 시행하였다. 관전압과 관전류, 부가여과 필터를 조절하여 유효 선량을 최대 77% 까지 감소시킬 수 있었다. 검사조건별로 다소간의 차이는 있으나 영상평가 결과 비슷한 품질의 영상을 얻을 수 있었다.

Keywords

References

  1. M. J. Kim, K. H Do, K. P. Kim, J. Y. Hwang, H. J. Choi, & S. K. Kim. (2014). "A study on the radiation dose management system and plan for patients." Korea Health & Medical Research Institute, 1-155.
  2. M. Korner, C. H. Weber, S. Wirth, K.-J. Pfeifer, M. F. Reiser, and M. Treitl, "Advances in Digital Radiography: Physical Principles and System Overview1," Radiographics,Vol. 27, No. 3, pp. 675-686, 2007. https://doi.org/10.1148/rg.273065075
  3. O. W. Hamer, C. B. Sirlin, M. Strotzer,I. Borisch, N. Zorger, S. Feuerbach, and M. Volk, "Chest Radiography with a Flat-Panel Detector: Image Quality with Dose Reduction after Copper Filtration1," Radiology,Vol. 237, No. 2, pp. 691-700, 2005. https://doi.org/10.1148/radiol.2372041738
  4. J. A. Seibert, "Tradeoffs between image quality and dose," Pediatric Radiology, Vol. 34, No. 3, pp. S183-S195, 2004. https://doi.org/10.1007/s00247-004-1268-7
  5. J. A. Seibert, "Digital radiography: image quality and radiation dose," Health Physics, Vol. 95, No. 5, pp. 586-598, 2008. https://doi.org/10.1097/01.HP.0000326338.14198.a2
  6. R. S. Jacob, E. Vano-Galvan, E. Vano, N. G. Ruiz, J. F. Soto, D. M. Barrio, and C. Prieto, "Optimising the use of computed radiography in pediatric chest imaging," Journal of Digital Imaging, Vol. 22, No. 2, pp. 104-113, 2009 https://doi.org/10.1007/s10278-007-9071-2
  7. Hennings, S.P., Garmer, M., Jaeger, H.J., Classen, R., Jacobs, A., Gissler, H. M., ... & Mathias, K.(2001). Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography. Eur. Radiol. 11, 1688-1696. https://doi.org/10.1007/s003300000795
  8. B. R. Park, D. W. Seong,(2010) "Comparison of image quality and exposure dose by changes in tube voltage and tube current in digital chest radiography." Korean Journal of Radiology. 62(2 : 131-137. https://doi.org/10.3348/jksr.2010.62.2.131
  9. K. W. Kim, Y. R. Kwon, S. W. Seo, K. T. Kwon, J. Y. Oh, S. Y. Son, J. W. Min, (2015). "Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography." Journal of Radiological Science and Technology Vol, 38(3), 205-211. https://doi.org/10.17946/JRST.2015.38.3.03
  10. Ron, E. (1998). Ionizing radiation and cancer risk: evidence from epidemiology. Radiation research, 150(5s), S30-S41. https://doi.org/10.2307/3579806
  11. Don, S., MacDougall, R., Strauss, K., Moore, Q. T., Goske, M. J., Cohen, M., ... & Lehman, L. (2013). Image gently campaign back to basics initiative: ten steps to help manage radiation dose in pediatric digital radiography. American Journal of Roentgenology, 200(5), W431-W436. https://doi.org/10.2214/AJR.12.9895

Cited by

  1. 미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석 vol.44, pp.1, 2017, https://doi.org/10.17946/jrst.2021.44.1.1
  2. 치과 방사선 촬영의 부가 필터 사용에 따른 유효선량 평가: 구내 촬영에 대한 PC-Based Monte Carlo Program 분석 vol.15, pp.4, 2017, https://doi.org/10.7742/jksr.2021.15.4.491