• Title/Summary/Keyword: 아말감제거

Search Result 9, Processing Time 0.02 seconds

Changes in Urinary Mercury Levels after Removal of Amalgam Fillings (어린이에서 구강내 아말감 제거 후 요중 수은농도 변화)

  • Jin, Hye-Jung;Sakong, Joon;Song, Keun-Bae;Jeon, Eun-Suk;Kim, Ki-Rim;Choi, Youn-Hee
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.190-195
    • /
    • 2015
  • The objective of this study is to estimate the relationship between amalgam removal and urinary mercury levels. To measure urinary mercury concentration, urine of participants was collected at baseline, immediately, 24 hours and 48 hours after removal of amalgam restorations. The statistical analysis was performed using IBM SPSS Statistics ver. 20.0. The overall mean urinary mercury concentration at baseline, immediately, 24 hours and 48 hours after removal of amalgam restorations was 2.77, 2.75, 2.95 and $4.00{\mu}g/g$ creatinine, respectively. Logistic regression model shows that the gender leads to increased odds of high urinary mercury concentration in children (odds ratio, OR=1.99), even after adjusting for high amalgam surfaces (OR=1.23) and fish consumption (OR=1.26) at the baseline. Our findings suggest that mercury exposure from dental amalgam adversely impact health and therefore are a health risk.

Association between amalgam removal and urinary mercury concentration: a pilot study (아말감 충전물 제거와 뇨중 수은농도의 관련성 평가: 예비연구)

  • Baek, Hye-Jin;Sa, Kong-Joon;An, Seo-Young;Lee, Hee-Kyung;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.431-438
    • /
    • 2012
  • Objectives : The aim of this study was assessment of the variation of urinary mercury concentrations after removal of amalgam fillings in children. Methods : 10 elemental school children with amalgam filling tooth surfaces were took part in this study. One dentist recorded the number of amalgam filling surface, and general characteristics of subjects were surveyed by questionnaire. Each urine samples were collected before, immediately after and after 24 hours amalgam removal. The statistical analysis was performed using the SPSS 18.0. Results : The mean concentration urinary mercury immediately after amalgam removal was higher ($5.70{\pm}1.20{\mu}g/g$ creatinine) than before amalgam removal ($5.28{\pm}1.53{\mu}g/g$ creatinine). The mean concentration urinary mercury level whose have 1-10 amalgam removal surfaces was increased after amalgam removal compared with before. Conclusions : Mercury concentration in urine was influenced by amalgam removal.

A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION (Sealed amalgam restoration의 미세누출에 관한 연구)

  • Lee, Sang-Heon;Lee, Jae-Cheoun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • Amalgam, though a widely used dental material, does not bond to the tooth substrate Therefore, retentive preparation of the cavity is necessary. Such amalgam restorations, until corrosion products form and plug the margin, will show significant marginal leakage. Unless this is prevented early on, saliva and bacteria may enter the cavity causing postoperative hypersensitivity, dissolution and collapse of the restoration, discoloration of the margin and secondary caries, leading to shortened life-span of the restoration and pulpal pathosis. Recently, a method of restoration has been introduced whereby tooth material can be preserved, cavity margin can be sealed and preventive treatment of pit and fissure can be administered while retaining all the advantages of conventional amalgam restorations. Such sealed amalgams involve removing the carious lesion without extending the cavity for prevention and using pit and fissure sealants to seal cavity margins and pit and fissures to reduce microleakage. In this study, finishing of the amalgam and sealant application were performed after different intervals following of amalgam restoration to compare the microleakage of sealed and conventional amalgam restorations. Thirty bicuspids were prepared with Class V cavity preparations on the buccal and lingual surfaces. After amalgam placement, they were divided into the following groups and treated accordingly. Group 1 : Polishing after 24 hours Group 2 : Immediate sealant application without polishing Group 3 : No polishing, but sealant applied after thermocycling 500 times After treatment, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue kept in a $37^{\circ}C$ incubator at 100% humidity for 24 hours. The teeth were then embedded in resin and cut bucco-lingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage, The following results were obtained : 1. Group 2 showed the least microleakeage, while group 1 showed the greatest. 2. Group 1 showed significantly greater microleakage compared to group 2 (p<0.05). However, no significant differences were found between group 1 and 3(p>0.05). No significant differences in microleakage were also found between cup 2 and 3(p<0.05).

  • PDF

Conservation and Analysis of Gilding Silver Buddhas and Relics Discovered Inside Buddha of Joseon Period (조선시대 은제금도금불상과 그 복장품의 보존처리 및 재질연구)

  • Kwon, Yoonmi;Park, Seungwon;Yu, Heisun;Choi, Heeyoon;Yun, Eunyeong
    • Conservation Science in Museum
    • /
    • v.9
    • /
    • pp.31-49
    • /
    • 2008
  • We have investigated and conserved three small Buddha statues dating from Joseon period that were purchased by the National Museum of Korea. Chemical analysis and investigation of internal structures were enabled us to identify its compositions and hollow spaces which have various materials just like fabrics, silver ornaments, beads and wood fragments. The fabrics date from the early years of the Joseon dynasty to the middle one. The compositions of matrix of the Buddha statues vary 80-90 wt% Ag and 7-15 wt% Cu. And its surface layers were gilt with amalgam. Mechanical and chemical cleaning with EDTA-2Na were applied together during the cleaning process.

A Study on Conservation and Manufacturing Technique of Saddle Ornament(Angyo) Excavated from South Tomb Hwangnamdaechong (황남대총 남분 출토 용문투조은판피안교의 보존과 제작기법 연구)

  • Kwon, Heehong;Jeon, Hyosoo;Yun, Eunyoung
    • Conservation Science in Museum
    • /
    • v.12
    • /
    • pp.59-69
    • /
    • 2011
  • The conservation treatment and production technique of Yongmuntujoeunpanpi-Angyo(Saddle Ornament) at Hwangnamdaechong were: The conservation treatment removed foreign material by using both chemical method and physical method to reinforce and to recover area by jointing that was destroyed and weakened. Not only Angyogeumgu but also Jwamokseongeumgu was made of 99wt% or more silver (Ag), and Wondujeong, Naeyeongeumgu and Bokryung were produced by amalgam gold plaiting. Not only Angyogeumgu but also Jwamokseongeumgu that was cast with silver plate was jointed by folding both and putting Naeyeongeumgu on it and then nailing gild ofwondujeong at specific interval. A tree that grew up in curve was used, and it was adhered by plain weave fabric of hemp cloth and wool.

A STUDY OF THE MERCURY VAPOR MEASUREMENT DURING AMALGAM REMOVAL (충전(充塡)된 아말감 제거시(除去時) 발생(發生)되는 수은증기량(水銀蒸氣量) 측정(測定)에 관(關)한 연구(硏究))

  • Na, Keung-Kyun;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.85-92
    • /
    • 1984
  • The aim of this study was to examine the influence of the speed of grinding and coolants on mercury vaporization during amalgam removal. Forty amalgam filled stone dies were stored at $37^{\circ}C$ and 100% relative humidity for 7 days prior to the beginning of the mercury vapor experiment and were divided into 4 different groups; In Group I; Used by high speed without coolant & evacuator during amalgam removal. In Group II; Used by high speed with coolant & evacuator during amalgam removal. In Group III; Used by low speed without coolant & evacuator during amalgam removal. In Group IV; Used by low speed with coolant & evacuator during amalgam removal. The amalgam specimens were removed in a 30-second time period and mercury vapor was collected with membrane filter at 27mm from the site of removal and 45 degree above there. Samples in Group II, IV were removed with coolant spray at a flow rate of 30 ml/min with high-velocity evacuator. Mercury vapor collected membrane filter was analysed by Atomic Absorption Spectrophotometer using cold vapor method. The results were as follows; 1. The mercury vapor levels were obtained all of the Groups. 2. The mercury vapor levels of the Group II, IV (with coolant & evacuator) were less than that of the Group I, III (without coolant & evacuator). 3. The highest mercury vapor level recorded during amalgam removal procedure was Group I (used by high speed without coolant & evacuator) and its record was $0.78{\pm}0.09\;mg/m^3$, which exceed the T.L.V. by 15 times. 4. The mercury vapor level of the Group IV (used by low speed with coolant & evacuator) was more than that of the Group II (used by high speed with coolant & evacuator), but its difference was not significant, statistically. (p > 0.05)

  • PDF

Study on the Infection Control and Dental waste Disposal in Dental Clinic Located in Seoul City (서울시 치과의원의 진료실 감염관리 및 폐기물 처리 실태 조사연구)

  • Kang, Jae-Kyoung;Kim, Eun-Sook;Kim, Kyung-Mi
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.105-113
    • /
    • 2002
  • This study was aimed to investigate the practice on the infection control and dental waste disposal in dental clinic. The data used in this study had been collected in 100 dental clinics located in Seoul city from August to October, 2001. It was shown that examination instruments, oral surgery instruments, and periodontal instruments were almost sterilization in dental clinic. It was high in the recognition of individual protection but it was low in the degree of practice. Therefore, the practice in infection control is very important to dental team for safety of patients and operators.

  • PDF

Study of the Production Techniques Used in the Goryeo-period Gilt-Bronze Case for Acupuncture in the Collection of the Royal Museums of Art and History, Belgium (벨기에 왕립예술역사박물관 소장 고려시대 금동침통의 과학적 보존처리를 통한 제작기법 연구)

  • Lee, Jaesung;Park, Younghwan
    • Conservation Science in Museum
    • /
    • v.27
    • /
    • pp.147-164
    • /
    • 2022
  • Over 200,000 Korean cultural heritage items are currently located abroad. They have made their way to 22 countries under different circumstances and with unique backgrounds. While some of them continue to contribute to promoting Korean culture around the world, others cannot be exhibited due to damage or poor condition. In view of these circumstances, the Overseas Korean Cultural Heritage Foundation (OKCHF) has since 2013 provided museums and art galleries abroad with support for the conservation, restoration, and utilization of the Korean cultural heritage items that they house. As a part of these efforts and on the occasion of the 120th anniversary of the diplomatic relationship between the Republic of Korea and the Kingdom of Belgium in 2021, a gilt-bronze case for acupuncture needles dating to the Goryeo period (918-1392) from the collection of the Royal Museums of Art and History (RMAH), Belgium was brought to Korea for conservation treatment. The primary purpose of this conservation treatment was to restore the original form of the relic and slow to the degree possible the progress of corrosion. The conservation treatment of the gilt-bronze case followed the fundamental order of conservation treatment: removal of corrosive substances, stabilization, and reinforcement. Since this was the first case of restoring metallic cultural properties under the abovementioned support program by the OKCHF, special methodologies distinct from those available in overseas institutions were required. Diverse scientific methods (e.g., X-ray inspection, CT scanning, 3D microscopy) were applied to identify the metalcraft techniques used in the Goryeo period. The analysis found that several designs, including lotus and scrollwork, were exquisitely engraved on the surface of the case by making dots using a round-edged chisel. A bronze plate engraved with designs was rolled into a cylindrical form. The ends were overlapped by 2 to 3 centimeters and then attached to each other by silver soldering. The overlapping ends were welded flat with nearly no gaps. As the final process in the production, the case was lavishly gilt with gold powder using amalgam gilding. The conservation treatment of the gilt-bronze case for acupunctural needles in the RMAH collection restored the original form of the relic and arrested further corrosion. Above all, it revived the historic and academic value of the overseas Korean cultural heritage through scientific analysis.

EVALUATION OF THERMAL DIFFUSION IN LOWER End PRIMARY MOLAR WITH THERMOGRAPHY AND FINITE ELEMENT ANALYSIS (Thermography와 유한요소분석법을 이용한 하악 제2유구치의 열확산도 평가)

  • Park, Hee-Seung;Kim, Yong-Kee;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.519-528
    • /
    • 2002
  • It is not a rare occasion that certain dental procedures involving tooth reduction being peformed under inadequate water cooling due to a variety of reasons. This situation could possibly inflict the critical insult to the pulpal tissue of indicated tooth. The purpose of this experiment was to study the pattern of diffusion of external heat produced during routine dental procedures into the pulpal tissue. 30 stone blocks containing three lower second primary molars were used for certain restorative procedures and the temperature of the indicated tooth surface was measured by thermography(Inframetrics 600) and further used as a baseline data for the finite element analysis model fabrication designed in order to evaluate the pattern of thermal diffusion. The ranges of highest surface temperature measured from several dental procedures under water cooling and non-water cooling were $30.8^{\circ}C{\sim}43.6^{\circ}C$ and $51.2^{\circ}C{\sim}103.4^{\circ}C$ respectively. Among procedures studied, crown preparation showed the highest value and amalgam removal showed the lowest. Comparisons between data measured under water cooling and non-water cooling conditions have shown the statistically significant difference(p<0.05). All the non-cooling conditions have shown the relatively larger increment of temperature change at the pulp horn area than the cooling conditions. The results of this study strongly indicate that the water coolant is the essential element in restorative procedures for the maintenance of healthy pulp. Further related studies involving more procedures and conditions are recommended.

  • PDF