• 제목/요약/키워드: 심장CT

Search Result 418, Processing Time 0.023 seconds

Three-Dimensional Printed Model of Partial Anomalous Pulmonary Venous Return with Biatrial Connection (양측 심방 연결을 형성하는 부분 폐정맥 환류 이상의 3D 프린팅 모델)

  • Myoung Kyoung Kim;Sung Mok Kim;Eun Kyoung Kim;Sung-A Chang;Tae-Gook Jun;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1523-1528
    • /
    • 2020
  • Partial anomalous pulmonary venous return (PAPVR) is a rare congenital cardiac anomaly that can be difficult to detect and often remains undiagnosed. PAPVR is diagnosed using non-invasive imaging techniques such as echocardiography, CT, and MRI. Image data are reviewed on a 2-dimensional (D) monitor, which may not facilitate a good understanding of the complex 3D heart structure. In recent years, 3D printing technology, which allows the creation of physical cardiac models using source image datasets obtained from cardiac CT or MRI, has been increasingly used in the medical field. We report a case involving a 3D-printed model of PAPVR with a biatrial connection. This model demonstrated separate drainages of the right upper and middle pulmonary veins into the lower superior vena cava (SVC) and the junction between the SVC and the right atrium, respectively, with biatrial communication through the right middle pulmonary vein.

Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan) (폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교))

  • 이조한
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

Left Atrial Appendage Aneurysm: A Case Report (좌심방 부속기 동맥류: 증례 보고)

  • Young Jae Choi;Jeung Sook Kim;Yoon Ki Cha;Kang Min Han
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1400-1405
    • /
    • 2022
  • Left atrial appendage aneurysm (LAAA) is a rare heart anomaly caused by congenital dysplasia of the pectinate muscle or by an acquired pathological condition of the mitral valve or cardiac muscle. It is often incidentally discovered during chest CT or echocardiography as an abnormal dilatation of the LAA. LAAA is associated with life-threatening complications and most patients require surgical treatment. Therefore, it is important to evaluate associated complications as well as precise diagnoses. This report presents the case of a surgically confirmed LAAA in a 53-year-old female. We also discuss the pathophysiology of LAAA and significant findings related to mortality that can be detected on CT and MRI.

Fully Automatic Heart Segmentation Model Analysis Using Residual Multi-Dilated Recurrent Convolutional U-Net (Residual Multi-Dilated Recurrent Convolutional U-Net을 이용한 전자동 심장 분할 모델 분석)

  • Lim, Sang Heon;Lee, Myung Suk
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2020
  • In this paper, we proposed that a fully automatic multi-class whole heart segmentation algorithm using deep learning. The proposed method is based on U-Net architecture which consist of recurrent convolutional block, residual multi-dilated convolutional block. The evaluation was accomplished by comparing automated analysis results of the test dataset to the manual assessment. We obtained the average DSC of 96.88%, precision of 95.60%, and recall of 97.00% with CT images. We were able to observe and analyze after visualizing segmented images using three-dimensional volume rendering method. Our experiment results show that proposed method effectively performed to segment in various heart structures. We expected that our method can help doctors and radiologist to make image reading and clinical decision.

A Case Report of Echocardiography of Non-rheumaic Giant Left Atrium (비-류마티스성 거대 좌심방의 심장 초음파 검사 증례 보고)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.443-451
    • /
    • 2022
  • In this case, non-rheumatic GLA was observed and it was intended to report a case of ultrasound examination. The case patient, a 60-year-old male, visited the emergency room for dyspnea and palpitations. For radiology examination, chest X-ray examination and CT examination were performed, and a giant left atrium was confirmed. Echocardiography was performed to find the cause of the giant left atrium. Echocardiography The size and volume of the left atrium were evaluated by Simpson's method, and the giant left atrium with LVEDVI 6 times larger than that of the general giant left atrium could be evaluated. Also, a giant left atrium in a patient without rheumatic heart disease is evaluated as a very rare case. Since non-rheumatic giant left atrium could be caused by functional mitral regurgitation, diastolic dysfunction. It was confirmed that ultrasonography, which allowed both morphological and hemodynamic examinations, could be a useful case.

Assessment of Primary Spontaneous Pneumothorax Using Chest Computerized Axial Tomography (원발성 자연기흉에서 흉부 컴퓨터 단층촬영의 진단적 의의)

  • Kim, Mun-Hwan;Lee, Cheol-Ju;Kim, Se-Hwan
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.209-213
    • /
    • 1993
  • The pathogenesis of the primary spontaneous pneumothorax is the rupture of subpleural bleb or bullae and subsequent sudden collapse of the affected lung. Mostly, the bullae or blebs are present bilaterally, but detecting the number, size, and location of the causating foci by plain chest film is quite difficult . We have performed chest CT scans for detecting the bullous lesions in 33 cases of primary spontaneous pneumothorax, and compared the results with surgical findings.1. Seventy-four blebs were identified in the chest CT scan, and 100 blebs or bullae were detected surgically [ Sensitivity was 0.74 ].2. Diagnosis rate was 80% [40/50] at right upper lobe, 75.7% [28/37] at left upper lobe, 55.6% at right lower lobe, and 25.0% at left lower lobe, respectively.3. Blebs or bullae smaller than 1 cm of its diameter were detected by 57.1% [24/42] of sensitivity, and in the cases of size larger than 1 cm, it revealed 86.2% [50/58] of sensitivity respectively.4. Of the 45 cases, 7 cases were false negative [15.6%], most of these were ruptured or small size [< 0.5 cm]. 5. One case was false positive, which was irregular adhesion at the apex of the lung.6. We could detect blebs or bullae with preoperative CT scans in 84.4% [38/45] of total patients. In conclusion, chest CT scan is a very advantageous diagnostic tool for proper management and preventing recurrence of primary spontaneous pneumothorax patient.

  • PDF

Median Sternotomy for Simultaneous Bilateral Bullectomy (정중 흉골절개술을 통한 동시적 양측 폐기포 절제술)

  • Gwak, Yeong-Tae;Han, Dong-Gi;Lee, Sin-Yeong
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.763-768
    • /
    • 1992
  • To prevent recurrence of spontaneous pneumothorax, 23 patients were operated through median sternotomy for simultaneous resection of bilateral bullae, And 27 patients with spontaneous pneumothorax were treated with unilateral thoracotomy, We studied the number, duration and sites of recurrence including findings of CT scan, as well as comparing the both operated group. The incidence of spontaneous pneumothorax was 88% in patients with the ages between 16 to 35 Forty one patients[82%] were operated with the indication of recurrent pne-umpthorax. The number of pneumothorax attack was 2.34 per patient with recurrent pneumothorax. The 87.8% of recurrence was occured within 6 months from last attack. Ips-ilateral recurrnet pneumothorax was 56.1% and contallateral involve was 43.9%. The bilaterality of visible bullae was 90.9% in the findings of chest CT scan and 91.3% in the operative finding. The sensitivity and accuracy for bulla detection with chest CT were 92.6%, respectively. Exclude one case of complicated median sternotomy infection, the postoperative hospital stay was shorter in median sternotomy approached group[P<0.05]. In conclusion, the bullous lesions of the lung have tendency of bilaterality so that median sternotomy for simultaneous resection of bilateral bullae should be considered in patients with contralateral visible bullae with chest CT.

  • PDF

The Value of Mediastinoscopy for Evaluation of Mediastinal Lymph Nodes in Bronchogenic Carcinoma : Accuracy of Mediastinoscopy (원발성 폐암에서 종격동 림프절 평가에 대한 종격동경 검사의 가치)

  • O, Sang-Jun;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.24 no.8
    • /
    • pp.751-756
    • /
    • 1991
  • For the period from June 1988 to July 1991 we studied 29 patients who were judged to have operable disease before mediastinoscopy on clinical criteria[absence of distant metastases, phrenic or laryngeal nerve paralysis, positive scalene node biopsy, and malignant pleural effusion]. All patients had computed tomography and mediastinoscopy prior to operation. In the present study, the sensitivity, specificity, and accuracy of CT were 92%, 56%, and 72%, respectively. And the sensitivity, specificity, and accuracy of mediastinoscopy were 92%, 100%, and 97%, respectively. We concluded that because of the low accuracy of CT, CT cannot replace mediastinoscopy, and routine mediastinoscopy should be performed in preoperative staging of bronchogenic carcinoma.

  • PDF

Low-dose Chest CT in Evaluation of Coronary Artery Calcification: Correlation with Coronary Artery Calcium Score CT (관상동맥 석회화 평가에서 저선량 흉부 CT와 관상동맥 석회화검사의 일치도)

  • Yon-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1033-1039
    • /
    • 2023
  • Low-dose chest CT, which is used as a lung screening test, also includes information on coronary artery calcification within the scan range. The purpose of this study was to investigate the usefulness of determining coronary artery calcification using Low-dose chest CT. Those who underwent low-dose chest CT and coronary artery calcification score CT on the same day were eligible. Coronary artery calcium score CT results were divided into 4 groups (Low: 1〈CACS〈10, Mild: 10〈CACS〈100, Moderate: 100〈CACS〈400, High: 400〈CACS) by referring to the Coronary artery calcium score categories and risks. After selecting 30 people each group, five radiotechnologists with more than 15 years of experience in coronary artery calcium measurement retrospectively analyzed the presence or absence of coronary artery calcification in low-dose chest CT images. The results of the five observers' uniform interpretation of the low-dose chest CT image were consistent with the coronary artery calcium score CT results in Low group: 56%, Mild group: 96.6%, Moderate group: 100%, and High group: 100%. appeared. In the Low group, all 5 observers observed calcification in 17 out of 30 cases, and in 7 cases all 5 observers decided that calcification could not be identified. Coronary artery calcification could be observed in 100% of asymptomatic adults with a calcium score of 15 or higher in low-dose chest CT scans. The minimum calcium score that can be identified is 1, and it was found that even very small calcifications can be identified when the subject's body size is small or the scan is performed at a time when heart movement is minimal.