• Title/Summary/Keyword: 시간-주파수 분석법

Search Result 195, Processing Time 0.03 seconds

Extraction of Cole-Cole Parameters from Time-domain Induced Polarization Data (시간영역 유도분극 자료로부터 Cole-Cole 변수 산출)

  • Kim, Yeon-Jung;Cho, In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.164-170
    • /
    • 2021
  • Frequency-domain and time-domain induced polarization methods can provide spectral information about subsurface media. Analysis of spectral characteristics has been studied mainly in the frequency-domain, however, time-domain induced polarization research has recently become popular. In this study, assuming a homogeneous half-space model, an inversion method was developed to extract Cole-Cole parameters from the measured secondary potential or electrical resistivity. Since the Cole-Cole parameters of chargeability, time constant, and frequency index are not independent of each other, various problems, such as slow convergence rate, initial model problem, local minimum problem, and divergence, frequently occur when conventional nonlinear inversion is applied. In this study, we developed an effective inversion method using the initial model close to the true model by introducing a grid search method. Finally, the validity of the developed inversion method was verified using inversion experiments.

Comparison of Damping Ratios by Half Power Bandwidth Method and Synchronized Human Excitation (하프파워법과 인력가진법에 의한 감쇠율 비교)

  • Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.95-103
    • /
    • 2008
  • This paper is concerned with the damping ratios of two methods, which are frequency domain and time domain approach. Ambient vibrations and synchronized human excitation test were conducted to three reinforced concrete buildings ranging from eleven to nineteen stories. The performance of the half power bandwidth method was investigated using three kinds of sample size, 1024, 2048, and 4096. The damping ratio by synchronized human excitation ranges from 1.05% to 1.22% in the long direction and from 1.16% to 1.50% in short direction. Damping by half power bandwidth method is slightly more overestimated than the synchronized human excitation due to insufficient record length. Damping evaluation by half power bandwidth method was found to be enhanced by using the narrower bandwidth with long recorded data.

  • PDF

Detection of Ventricular Fibrillation using Time-Frequency Analysis (시간-주파수 공간 분석법을 이용한 심실세동의 자동 검출에 관한 연구)

  • 이승하;황성오;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.561-571
    • /
    • 1999
  • 심실세동은 환자의 생명을 위협하는 가장 치명적인 부정맥으로서, 심실세동의 발견즉시 특별한 조치를 취하지 못할 경우 환자는 급사한다. 심실세동을 정지시키는 유일한 방법은 전기적 제세동이며 이는 환자의 심장 부위에 전기적 에너지를 가해 정상 심장 리듬을 되찾도록 하는 방법이다. 심실세동의 발생은 예측할 수 없고, 이를 진단하기 위한 심전도 교육을 모든 의료인에게 할 수 없으므로 심전도를 자동 분석하여 심실세동을 조기에 검출하는 자동 분석장치의 개발은 심실세동에 의한 급사를 줄이는데 매우 중요하다. 본 연구에서는 교차간섭성분의 제거 능력이 뛰어나며 쉽게 구사할 수 있는 Choi-Williams distriguteion (CWD) 방법을 이용하여 급사를 초래할 수 있는 심실세동을 자동 검출하는 알고리즘을 개발하였다. 그리고 개발된 알고리즘의 성능을 검증하기 위하여 본 논문에서는 두 그룹의 심실세동 데이터를 사용하였다. 검출 알고리즘은 심실세동의 시간 및 주파수 특성을 일곱가지 조건들에 대한 만족 여부를 이용하여 심실세동을 판정하였고, 실험의 민감도와 선택도는 각각 92.1%, 97 .2% 이다.

  • PDF

A Study on Frequency-Time Plane Analysis of Wavelet (웨이브렛의 주파수-시간 평면 해석에 관한 연구)

  • Bae, Sang-Bum;Ryu, Ji-Goo;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.451-454
    • /
    • 2005
  • Recently, many methods to analyze signal have been proposed and representative methods are the Fourier transform and wavelet transform. In these methods, the Fourier transform represents signal with combination cosine and sine at all locations in the frequency domain. However, it doesn't provide time information that particular frequency occurs in signal and depends on only the global feature of the signal. So, to improve these points the wavelet transform which is capable of multiresolution analysis has been applied to many fields such as speech processing, image processing and computer vision. And the wavelet transform, which uses changing window according to scale parameter, presents time-frequency localization. In this paper, we proposed a new approach using a wavelet of cosine and sine type and analyzed features of signal in a limited point of frequency-time plane.

  • PDF

A Study on the EMI Signal Analysis and Denoising Using a Wavelet Transform (웨이브렛 변환을 이용한 EMI 신호해석 및 잡음제거에 관한 연구)

  • 윤기방;박제헌;김기두
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, the different frequency component and time informations from an EMI signal are extracted simultaneously using a wavelet transform and the results of transform in the time and frequency domain are analyzed. Frequencies are extracted from the EMI signal by performing the multiresolution analysis using the Daubechies-4 filter coefficients and the time information through the results of wavelet transform. We have tried the correlation analysis to evaluate the results of wavelet transform. We have chosen the optimal wavelet function for an object signal by comparing the transformed results of various wavelet functions and verified the simulation examples of waveform and harmonic analysis using a wavelet transform. We have proved the denoising effect to the EMI signal using the soft thresholding technique.

  • PDF

Atrial Fibrillation Pattern Analysis based on Symbolization and Information Entropy (부호화와 정보 엔트로피에 기반한 심방세동 (Atrial Fibrillation: AF) 패턴 분석)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1047-1054
    • /
    • 2012
  • Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice, and its risk increases with age. Conventionally, the way of detecting AF was the time·frequency domain analysis of RR variability. However, the detection of ECG signal is difficult because of the low amplitude of the P wave and the corruption by the noise. Also, the time·frequency domain analysis of RR variability has disadvantage to get the details of irregular RR interval rhythm. In this study, we describe an atrial fibrillation pattern analysis based on symbolization and information entropy. We transformed RR interval data into symbolic sequence through differential partition, analyzed RR interval pattern, quantified the complexity through Shannon entropy and detected atrial fibrillation. The detection algorithm was tested using the threshold between 10ms and 100ms on two databases, namely the MIT-BIH Atrial Fibrillation Database.

Identification on Principle of Acoustic Wave Propagation Characteristics in a Gas Pipe (가스 배관 내부의 음파 전달 특성에 관한 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon;Jang, Sang-Yup;Koh, Jae-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.797-804
    • /
    • 2008
  • In the gas supply pipe, the gas leakage caused by the impact of the construct equipment is serious problem. The identification of the impact position is an important issue and an engineering work. For the basic research of this problem, the principle studies for the acoustic wave propagation in a gas pipe are proceeded in this paper. This principal work is based on the identification of the cut-off frequency associated with major modes of the gas pipe theoretically and experimentally The cut-off frequency is confirmed by STFT and cross-correlation function is used to identify the leakage position.

Development of diagnosis index for tick/click and tone noise of blower motor using vibration signals (진동 신호를 이용한 블로워 모터 틱/클릭과 톤 소음의 진단 지수 개발)

  • Lee, Songjune;Cheong, Cheolung;Lee, In-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.363-369
    • /
    • 2019
  • Various studies have been conducted for the diagnosis of noise condition of complex rotary machines. In this study, diagnosis index using vibration signal is developed for the efficient and objective assessment of noise condition of a blower motor. The noise most commonly caused by the abnormal blower motor are Tick/Click noise and Tone noise. According to cause and noise characteristics, time-frequency analysis is used to diagnose Tick/Click noise, and smoothing in frequency domain is used to diagnose tone noise condition. The noise condition of the blower motors were diagnosed using the developed index and these results are compared with the diagnostic results by the experts. As a result, the agreement rate was about 95 %.

Antenna Gain Measurement in Time Domain (시간 영역에서 안테나 이득 측정 연구)

  • Park, Jungkuy;Kim, Woo-Nyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1217-1227
    • /
    • 2012
  • There are several antenna calibration methods, so-called 3-Antenna Method, Standard Site Method, and Standard Antenna Method which measure the antenna gains or antenna factors. These methods yield the free space or quasi free space antenna gains in only the frequency domain. In this paper, an antenna calibration method using the time domain in the open area test site is discussed. The reflected waves due to the ground are traced in the time domain. After they are removed by the time gating function of network analyzer, the free space transmission coefficient $S_{21}$ is extracted. Such a way is applied to the broad band horn antenna ranging 1 GHz to 18 GHz, and the free space gains are obtained by Friis transmission equation. The method is checked by Standard Site Method in open area test site. The results show comparatively good agreement except for 18 GHz.

Power and Rate Adaptations in Multi-carrier DS/CDMA Communications over Rayleigh Fading Channel (레일레이 패이딩 채널에서 다중 반송자 DS/CDMA 통신 시스템의 전력-전송율 적응 방식)

  • Ah Heejune;Lee Ye Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.423-433
    • /
    • 2005
  • We present power(in frequency domain) and rate adaptation(in time domain) schemes in multicarrier (MC) direct-sequence code-division multiple-access(DS/CDMA) communications. Utilizing channel state information from the receiver, the adaptation schemes allocate power the user's sub-band with the largest channel gain. In the time domain, the transmission data rate is adapted for a desired transmission quality. In the case of single-user channels, a closed-form expression is derived for an optimal time domain power adaptation that minimizes the average bit error rate(BER). Channel inversion power adaptation is found to provide nearly optimal performance in this case, as the number of sub-bands or available average transmission power increase. Analysis and simulation results show the BER performance of the proposed power and rate adaptations with fixed average transmission power significantly improves the performance over the power allocation in the frequency domain only. Also, we compare the performance of the proposed power and rate adaptation schemes in MC-DS/CDMA systems with that of power and rate adapted single carrier DS/CDMA systems with RAKE receiver.