• Title/Summary/Keyword: 스펙트럼검사시스템

Search Result 29, Processing Time 0.026 seconds

A New System Development for the Spectrum Inspection of Optical Filters (광필터의 스펙트럼 검사시스템 개발)

  • Kim, Seung-Chul;Kim, Gyung-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.57-64
    • /
    • 2006
  • Optical filters in WDM are passive communication components used in case of transmitting and reflecting lights with specific wavelengths. In this paper, a novel mechanism for the automatic and optical alignment has been presented. It includes minimum axes not to be coupled each other. The automatic spectrum inspection system has been developed to improve the alignment time of reference optical ray, spectrum inspection time and inspection quality, simultaneously. It has been confirmed that the proposed spectrum inspection system is faster, more precise and more reliable than those based on the conventional handwork.

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

The Efficient Eye Image Check Algorithm for The Robust Iris Recognition System (강인한 홍채 인식 시스템을 위한 효율적인 눈 영상 검사 알고리즘)

  • 장자인;김귀주;손진호;이일병
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.328-330
    • /
    • 2003
  • 홍채 인식 시스템의 성능향상을 위해서는 전처리 단계에서 위조된 데이터나 잡음이 섞인 데이터를 걸러내는 과정이 매우 중요하다. 이 논문에서는, 강인한 홍채 인식 시스템을 위해서 두 단계로 이루어진 눈 영상 검사 알고리즘을 제안한다. 알고리즘의 첫 번째 단계에서는 동공 반지름과 눈꺼풀 움직임 변화량의 상관계수(coefficient)와 2차원 고속 퓨리에 변환(Fast Fourier Transform) 스펙트럼을 이용해 위조된 데이터를 찾아낸다. 두 번째 단계에서는 눈 영상에 눈 깜박임이나 속눈썹의 홍채영역 침범, 홍채 영상이 부분적으로 잘렸을 경우 등의 시스템의 성능저하의 원인이 되는 부적절한 데이터를 찾아낸다. 111영의 1734개의 눈 영상을 대상으로 실험한 결과, 제안된 알고리즘의 성공률은 96.5%였고 이러한 전처리 과정을 통해서 전체적인 시스템의 정확률을 향상시킬 수 있다.

  • PDF

Development of Linux based Real-Time Spectrum Analyzer for Puretone Audiometer (순음청력검사기를 위한 리눅스 기반 실시간 스펙트럼 분석기 개발)

  • Kang, Deok-Hun;Shin, Bum-Joo;Jeon, Gye-Rok;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2830-2839
    • /
    • 2011
  • Because the puretone audiometer is an important medical instrument used to diagnose hearing loss, the IEC and ANSI has been published a specification with which audiometer should comply. This paper describes development of Linux based real-time spectrum analyzer which is dedicated to puretone audiometer. It can measure not only hearing level but also compliance of IEC standard for puretone audiometer such as frequency accuracy, harmonic distortion, pulsed tone, narrow band noise and linearity. We have verified our real-time spectrum analyzer through comparing to commercial product.

Development of On-line Sorting System for Detection of Infected Seed Potatoes Using Visible Near-Infrared Transmittance Spectral Technique (가시광 및 근적외선 투과분광법을 이용한 감염 씨감자 온라인 선별시스템 개발)

  • Kim, Dae Yong;Mo, Changyeun;Kang, Jun-Soon;Cho, Byoung-Kwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • In this study, an online seed potato sorting system using a visible and near infrared (40 1100 nm) transmittance spectral technique and statistical model was evaluated for the nondestructive determination of infected and sound seed potatoes. Seed potatoes that had been artificially infected with Pectobacterium atrosepticum, which is known to cause a soil borne disease infection, were prepared for the experiments. After acquiring transmittance spectra from sound and infected seed potatoes, a determination algorithm for detecting infected seed potatoes was developed using the partial least square discriminant analysis method. The coefficient of determination($R^2_p$) of the prediction model was 0.943, and the classification accuracy was above 99% (n = 80) for discriminating diseased seed potatoes from sound ones. This online sorting system has good potential for developing a technique to detect agricultural products that are infected and contaminated by pathogens.

Consideration of the X-ray Spectrum Change and Resolution According to Added Filters, SID, A-Si (CsITl) in the Imaging System (A-Si(CsITl) 영상시스템에서 부가필터, SID에 따른 X선 스펙트럼변화와 해상력에 대한 고찰)

  • An, Hyeon;Kim, Jung-Hoon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.681-688
    • /
    • 2016
  • This study assess their quality of radiation on analysis of the spectrum of resolution suggesting IEC 61267 in radiation quality that RQA3, RQA5, RQA7, RQA9 and combination of clinical condition using several quality of radiation. In experiments edge method first, the spatial resolution assessment used image of the additional filter and SID is obtained the IEC 62220-1, spatial resolution and sharpness of the obtained image was evaluated in the MTF value 10%(0.1), MTF value 50%(0.5) using a Matlab program. Second, MCNPX simulation used spatial resolution analysis was radiation quality particle fluence and spectrum analysis in energy. As a result, make use of additional filter, image quality evaluation of SID that RQA3 radiation quality combination qualification is higher spatial resolution and sharpness make unused of additional filter and SID 100cm. RQA7 radiation quality combination qualification is higher that spatial resolution make unused of additional filter and SID 150cm. RQA9 radiation quality combination qualification is higher that spatial resolution and sharpness make used of additional filter and SID 180cm. spectrum analysis of radiation quality by reducing consequent errors occurring in the experiment that error due to the reproducibility of the X-ray tube, occur in an error of correction the detector suggest ideal conditions from spectrum analysis through MCNPX simulation. In conclusion, by suggesting spatial resolution and sharpness of result for various radiation quality, It provide basic data that radiation quality condition and quantitative assessment method for laboratory in clinical using detector evaluation.

Psychology analyzing system using spectrum component density ratio of EEG based on BCI-TAT (EEG 대역별 스펙트럼 활성 비를 활용한 BCI-TAT 기반 심리 분석 시스템)

  • Shin, Jeon-Hoon;Jin, Sang-Hyeon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.112-124
    • /
    • 2010
  • Studies that can find resolutions to problems of subjective psychiatric analysis must be performed and indeed they are in the process. However there still lies many problems in researches of mentality examination, which should be the foundation of finding potential resolutions. One of the biggest problems in the conventional system is that there are many different opinions by psychiatrists depending on their educations and experiences. There is no objective standard on the subjects and there is no effective psychiatric analysis method. Also, the characteristic of such examinations is that it cannot be applied to disabilities, foreigners and infants alyce the examination is ch examinconversation. The objective of this atudy is to standardize TAT(Thematic Apperception Test)analysiBallken index method so that subjective data from the examination can be excluded and the examination thus maklysithe examination objectified. Furthermore, objective result and patients' brain wave pattern is read with BCI(Brain Computer Interface) ch exaTherenvironment to Alsare it to brain wave characteristics vectors to reate brain-wave characteristics vector DB. Therefore, such DB can be utilize durlysithe examination and diagnosis to reate objective examination method and standardized diagnosis system. Thus, mentality examination can be performed only with brain-wave scans with BCI based TAT system.

The Feasibility Study on the Direct Use of the MC-derived Physical Quantities to Determine the Model Parameters of RTPS with -Model-Based Photon Dose Calculation Algorithm (모델기반 광자선량 계산방식을 사용하는 전산화치료계획장치의 모델변수 결정에 있어 몬테카를로 모사법에 의해 유도된 방사선 물리량의 직접 적용 가능성에 대한 연구)

  • 강세권;박희철;배훈식;조병철
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2004
  • The commissioning of a model-based treatment planning system requires many parameters to fit the measured depth doses and transverse profiles. For the commissioning of the Pinnacle$^3$ system, through the Monte Carlo (MC) simulation, the necessary parameters, including the photon spectrum, contaminant electrons, off-axis softening and fluency of photons, were observed. Through the simulation the parameters contained valuable information, but the calculated results of the Pinnacle$^3$ using the MC-derived parameters showed discrepancies with those measured for the off-axis softening and the fluency of photons. Even though the MC calculation produces reasonable values for the commissioning, the thorough physical basis of the Pinnacle$^3$'s commissioning process is needed in order to directly use the MC derived parameters.

  • PDF

Yoke Tube Crack Inspection by Using Acoustic Resonance Spectral Analysis (음향 공진 스펙트럼 분석을 통한 요크 튜브 크랙 검사)

  • Yeom, Woo-Jung;Hong, Yeon-Chan;Kim, Jin-Young;Kang, Joonhee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.108-114
    • /
    • 2018
  • Due to the development of nondestructive testing techniques, methods of inspecting cracks in mechanical parts have drawn attentions. Among various non-destructive testing methods the acoustic resonance method which analyzes the natural frequencies has been developed into a technique suitable for the prompt judgements of the existence of the defects in the mechanical parts. In this study, we investigated the crack inspection technique to examine the cracks in the yoke tubes by using the acoustic resonance method and realized the system to quickly detect the cracks. A 24bit ADC circuit and an MCU were installed for the smooth data collection, and a TCP / IP communication interface was configured for the data communication with PC. We used a microphone as a sensor measuring the vibrations. We constructed an analysis software to obtain the frequency spectra of the vibrations, to find the existence of the cracks, and to feedback to the user. Tests were conducted using the yoke tubes manufactured in the real industrial field. The tests were successfully conducted to distinguish the good products from the defective (cracked) products and confirmed that they can be employed in the actual industrial field.

Intrusion Sensor Using Fiber-Optic Mach-Zehnder Interferometer (광섬유 마하젠더 간섭계를 이용한 침입자 감지 센서)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.255-259
    • /
    • 2006
  • For the intruder detection, a buried fiber-optic sensor based on fiber-optic Mach-Zehnder interferometer is demonstrated. We buried the sensor arm in a styrene board and exerted pressure on it. The pressure-induced deformation speed has almost linear relationship with the output frequencies of the interference signals, and about 4.25 Hz frequency change per 0.01m/s was obtained. Also it has been shown that the amplitude of frequency component increases according to the weight of mass.