• Title/Summary/Keyword: 순음도

Search Result 111, Processing Time 0.022 seconds

Numerical Analysis on the Low Noise Designs of Savonius Wind Turbines by Inducing Phase Difference in Vortex Shedding (와류이탈 위상차를 이용한 사보니우스형 풍력터빈의 소음 저감 설계에 관한 수치적 연구)

  • Kim, Sanghyeon;Cheong, Cheolung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.269-274
    • /
    • 2014
  • In this study, low noise designs for a Savonius wind turbine were numerically investigated. As was reported in our previous study, the harmonic components with a fundamental frequency higher than the BPF were identified as being dominant in the noise spectrum of a Savonius wind turbine, and these components were a result of vortex shedding. On a basis of this observation, an S-shaped blade tip is proposed as a means of reducing the noise generated by small vertical(Savonius) wind turbines. This blade induces phase differences in the shedding vortices from the blades, and thus reduces the noise from the wind turbine. The aerodynamic noise characteristics of the conventional and "S-shaped" Savonius turbines were investigated by using the Hybrid CAA method where the flow field around the turbine is computed using the CFD techniques and the radiated noise are predicted by applying acoustic analogy to the computed flow field data. The degree of noise reduction resulting from the proposed design and its reduction mechanism were confirmed by comparing the predicted noise spectrum of these turbines and the flow characteristics around them.

Comparative Study of Functional Magnetic Resonance Imaging by Global Scaling Analysis (Global Scaling 분석방법에 따른 기능적 자기공명영상의 비교 연구)

  • Yoo, Dong-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.26-31
    • /
    • 2006
  • Purpose : To evaluate the effect of global scaling analysis on brain activation for sensory and motor functional MR imaging study. Materials and methods : Four normal subjects without abnormal neurological history were included. Arm extension-flexion movement was used for motor function and 1KHz pure tone stimulation was used for auditory function. Functional magnetic resonance imaging was performed at 3T MRI (GE, Milwaukee, USA) using BOLD-EPI technique and SPM2 was employed for data analysis. On data analysis, the brain activation images were obtained with and without global scaling by fixing other parameters such as motion correction and realignment. Results : The difference in brain activation between no scaling and global scaling was not large in case of right upper extremity movement (p<0.000001). For auditory test, brain activation with global scaling showed larger activation than that of without global scaling (p<0.05). Conclusion : A caution must be taken into account when analyzing functional imaging data with global scaling especially for functional study of small local BOLD signal change.

  • PDF

The Influence of Preemployment Medical Examination, Pure Tone Audiometry, and Simple Lumbar Spine X-ray Test on the Worker's Employment - The Result of Survey at Incheon Metropolitan City and Gyeonggi Province in Korea, the Year 2003 - (채용시 건강진단과 순음청력검사 및 요추부 단순방사선 검사가 근로자 채용에 미치는 영향 - 인천, 경기 지역 2003년 실태 조사 -)

  • Kim, Kyeong-Ja;Han, Sang-Hwan;Seong, Nak-Jeong
    • Korean Journal of Occupational Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.146-155
    • /
    • 2003
  • This study was conducted for investigating the status of management of preemployment health examination and to have an effect on the worker's employment. Health managers of 103 companies in Incheon metropolitan city and Gyeonggi were interviewed by telephone. Of 103 companies, 67(65.1%) said they don't hire the applicants who have an active pulmonary tuberculosis, 80(77.7%) companies said they health HBV carrier is acceptable but active HBV carrier is not 29(28.2%) companies said they don't hire the applicants who have a hypertension or diabetes mellitus, 42(40.8%) companies said they don't hire the applicants who have a hearing disturbance. If HIVD is suspicious in X-ray lumbar-sacral region, 37(78.7% of 47 companies) said they do not hire the applicants. 29(35% of 83 companies) said they cancel the employment of the applicants who are suspicious of noise induced hearing loss on preplacement health examination. From our survey, preemployment health examination was utilizing mainly as a tool for the selection of health employees who don't have a disease. Furthermore, in many companies, additional test items are being included and getting more strict the selection criteria for preemployment health examination. For the right use of preemployment health examination, author suggested that further studies were needed to select the adequate test items and establish the reasonable criteria for preemployment health examination.

  • PDF

Calculation Model of Time Varying Loudness by Using the Critical-banded Filters (임계 대역 필터를 이용한 과도음의 라우드니스 계산 모델)

  • Jeong, Hyuk;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.65-70
    • /
    • 2000
  • It is blown that the loudness is one of the most important metrics in assessing the sound quality and a calculation method for loudness has been standardized for steady sounds. In this study, a new loudness model is suggested for dealing with the transient sound for a unified analysis of various practical sounds. A signal processing technique is introduced for this purpose, which is required for the band subdivision and the prediction of band-level change of transient sounds. In addition, models for the post-masking and the temporal integration are adopted in the analysis of the loudness of transient sounds. In order to solve the problem of the conventional loudness model in the pure-tone signal processing, a critical band filter is employed in the analysis, which consists of 47 critical filters having a filter spacing of a half of the critical bandwidth. For testing the effectiveness of the present model, the predicted responses are compared with the experimental data and it is observed that they are in good agreements.

  • PDF

Broadband Noise Prediction of the Ice-maker Centrifugal Fan in a Refrigerator Using Hybrid CAA Method and FRPM Technique (복합 CAA 방법과 FRPM 기법을 이용한 냉장고 얼음제조용 원심팬의 광대역 소음 예측)

  • Heo, Seung;Kim, Dae-Hwan;Cheong, Cheol-Ung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.391-398
    • /
    • 2012
  • In this paper, prediction of centrifugal fan was conducted through combination the hybrid CAA method which was used to predict the fan noise with the FRPM technique which was used to generate the broadband noise source. Firstly, flow field surround the centrifugal fan was computed using the RANS equations and noise source region was deducted from the computed flow field. Then the FRPM technique was applied to the source region for generation of turbulence which satisfies the stochastic features. The noise source of the centrifugal fan was modeled by applying the acoustic analogy to the synthesized flow field from the computed and generated flow fields. Finally, the broadband noise of the centrifugal fan was predicted through combination the modeled noise source with the linear propagation which was realized using the boundary element method. It was confirmed that the proposed technique is efficient to predict the tonal and broadband noises of centrifugal fan through comparison with the measured data.

Variable Bitrate MPEG Audio (가변 전송율 MPEG 오디오)

  • Nam, Seung-Hyon
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.57-62
    • /
    • 1997
  • Two psychoacoustic models used in MPEG-1 employ different masking patterns, different masking indexes, and different computational procedures. As a result, Model 1 is inferior to Model 2 due to its worst case approach in computing the SMR even though it determines tonality and masking levels accurately. In this study, we investigate the performances of psychoacoustic models when we modify the MPEG-1 audio coder for variable bitrates. Simulation results show that Model 2 has a gain of 30 kbps in the dual channel mode and 20 kbps in the joint stereo mode. It is generally known that the joint stereo mode has a gain in bitrate compare to the dual channel mode. For signals with frequent attacks, this gain becomes larger in Model 1 than in Model 2. This is due to the fact that Model 1 uses the worst case approach in computing the SMR to reduce pre-echo

  • PDF

Development of Smart Phone Application with User Fitting for Hearing Impaired in Various Environment (환경별 사용자 피팅이 가능한 스마트폰 보청기 어플리케이션 개발)

  • Lee, K.;Kang, S.-I.;Park, G.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.121-128
    • /
    • 2015
  • In this paper, we introduce our smart phone application for hearing impaired people. Unlike previous hearing aids application, our application has both functions of self hearing tests and sound amplification. We provide user with two types of self hearing test, those are standard hearing test and detail hearing test. Each test has different advantages like short test time and accurate test result, however both tests provide reliable result. Our hearing test allows that user can measure their hearing loss level according to the frequency. Sound amplification function provide proper fitting formula by using NAL-NL1, and it guarantees high speech intelligibility. Our application can also memorize user's fitting data at specific test condition. Therefore those who using our hearing aids application can easily reset their hearing aids / earphone properties periodically. Our application is advanced at the aspect of self fitting function that no other previous application did. So we are expecting these comfortable processes about fitting lead the number of hearing aids user to be increased.

  • PDF

Study and Effects of Bone Conducted Signal on the Implantable Microphone (골전도를 통한 생체신호가 이식형 마이크로폰에 미치는 영향 및 고찰)

  • Woo, S.T.;Jung, E.S.;Kim, M.N.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • The fully implantable hearing devices (FIHDs) have been studied to compensate the defect of conventional hearing aids. Typically, a microphone for FIHDs was implanted under the skin of the temporal bone. So, implantable microphone characteristics can be affected by the eating food, chattering teeth and moving artifact. In this paper, we fabricated the physical model that was similar to characteristics of human temporal bone and skin, and we measured implanted microphone sensitivity for effect of bone conducted noise signal. For the measurement of microphone sensitivity, we applied 1 kHz pure sounds that were transmitted to implanted microphone and sine wave vibrations of varied frequency were simultaneously transmitted through the artificial bone. As a result, sensitivity of implanted microphone can be modified by bone conducted signal and this phenomenon was confirmed at varied frequency band.

Auditory responses in neonates; a preliminary report (신생아에서 관찰할 수 있는 청성반응)

  • 황순재;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.1-4
    • /
    • 1977
  • A variety of diagnostic means for evaluating the hearing ability of neonates and infants have been studied so far, and some physical responses of neonates and infants to loud sound is still of much value. The author studied some normal responses of 100 neonates (male 54, female 46) in our neonatal room from Jan, 1977 to April, 1977. We took 90dB pure tone at 3, 000Hz by Beltone Audiometer model l0D (ANSI 1969) for a stimulus. The results are as follows: 1. The range of the examinees' age is between 2 and 3.5 hours (average 2.4 hours), and auropalpebral response is in 39% (eyelid blinking 10%, eyelid widening 29%), Moro reflex in 35%, sucking response in 14%, cessation of movement in 6%, head turning response in 2%, and no response in 4%. 2. The duration of response is between 2 and 5 Seconds (average 3.3 seconds).

  • PDF

Audiological Findings of Congenital Ichthyosiform Dermatosis with Sensorineural Hearing Loss (난청을 동반한 선천성 어린선상 피부병의 청각학적 소견)

  • 한태희;최진택;김광현;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.40.3-41
    • /
    • 1981
  • The ichthyosiform dermatosis is consisted of a heterogenous group of hereditary disorders. Authors report a case of 26 year old female patient who has congenital ichthyosiform dermatosis associated with sensorineural hearing loss, neovascularization of cornea, partial alopecia and abnormalities of nails and teeth. The audiological findings of this patient were as follows: 1. Bilateral severe sensorineural hearing loss. 2. SISI scores: 100% at 1, 000 Hz and 4, 000 Hz on both ear. 3. Tone decay test: 25 dB decay at 1, 000 Hz and 4, 000 Hz respectively on both ear. 4. SRTs : 85 dB on both ear. 5. Speech discrimination scores : 80% at 95 dB hearing level(MCL) on both ear. With above results, cochlear lesion is suspected in this syndrome.

  • PDF