• Title/Summary/Keyword: 순간 화재

Search Result 68, Processing Time 0.022 seconds

탐방 - 남대문시장 고려상가

  • Jeong, Yu-Geun
    • 방재와보험
    • /
    • s.26
    • /
    • pp.30-31
    • /
    • 1985
  • 지난 3월 부주의와 방심에서 비롯된 남대문시장 화재를 두고 일부에서는 날벼락을 맞았다고 한다. 소형부탄가스통 8천여개가 연쇄적으로 폭발하면서 인근의 상가에 인화되어 순식간에 상가전체가 잿더미로 변해버린 남대문시장내 고려상가. 악몽과도 같은 그 순간을 잘 극복하고 한창 복구작업에 여념이 없는 현장을 찾았다.

  • PDF

The Causes and Analysis of Electrical Fires -focused on Dynamic Characteristics of RCD- (전기화재의 발생원인 및 분석 -누전차단기의 동작특성을 중심으로-)

  • 이상호
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • Recently, the occurrences of electrical fire have been suppressed by a residual current protective devices(RCD), a molded case circuit breaker(MCCB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the RCD to break the circuit in the case of the conductor fractures, the failure of pressure contacts on connecting points and the momentary short circuit of low voltage wiring. Therefore, it is require to study the constructive problem of the RCD. In this paper, we have tested the operation characteristics of the RCD according to the R load and R-L load in the conductor fractures, the failure of pressure contacts on connecting points and the momentary short circuit of low voltage wiring.

An Analysis of False Alarm Threshold Value by Heat Detector Using Heat Release Rate (열방출률을 이용한 열감지기의 오동작 경계값 분석)

  • 홍성호;김두현
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.26-30
    • /
    • 2003
  • This paper presents a study on the analysis for false alarm of heat detector using HRR(Heat Release Rate). And it is represented to threshold value and domain of false alarm. The HRR threshold value of false alarm is calculated to use parameters obtained by small scale fire-experiment. The experiment is conducted to measure detector activation time and flame spread of wood cribs fire, etc. The results show that HRR threshold value of Fixed type detector is 20.24 kW and rate of rise type detector is 13.59 kW, respectively.

A study on the neutral line compensator for prevention of rising at load voltage instantly when disconnect the neutral line in 3phase 4 line system (3상 4선식 배선의 중성선에 탈락시 부하 전압 상승 방지를 위한 중성선 보상기에 관한 연구)

  • Kim, Hyun-Woo;Baek, Dong-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.522-525
    • /
    • 2011
  • 3상 4선식 배선 라인에서 중성선이 탈락할 경우 부하측의 중선선에 연결된 일부의 부하측 전압은 급상승하게 되고 이로 인한 피해가 많으므로 본 연구에서는 배전라인의 점검시 또는 접촉 불량에 의하여 발생할 수 있는 중성선의 탈락을 순간 감지하고 이를 보상하여 별도로 중성선을 생성하여 새로운 중성선을 순간 제공함으로서 중성선 탈락에 의한 피해를 최대한 억제하고자 하는 것이다. 이로 인하여 부하측의 전압상승에 의한 전기적 재해를 사전에 미리 예방이 가능한 효과도 있게 된다.

  • PDF

An Experimental Study on the Characteristics of Sodium Fires (나트륨 화재 특성의 실험적 연구)

  • Bae, Jae-Heum;Ahn, Do-Hee;Kim, Young-Cheol;Mann Cho
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.471-483
    • /
    • 1994
  • A sodium fire facility with a test chamber of 1.7㎥ volume was constructed and operated to carry out experiments of sodium fires such as pool, spray, and columnar fires which might take place in sodium-related facilities. The experimental results of pool fires showed that the increase of temperature and pressure in the test chamber was much smaller than that of spray and columnar fires even though their amount of sodium injection in the chamber was much larger compared to other types of fires. And it was found in pool fires that the temperatures of sodium pool and the gas temperature in the test chamber had been maintained much longer than other types of fires, and that the chamber pressure had come to vacuum due to depletion of the oxygen for a large amount of sodium injection in the chamber. The experimental results of spray fires showed that sprayed sodium of small particles instantly reacted with oxygen, and that its reaction heat increased gas temperature and pressure of the test chamber rapidly and decreased them shortly. And the maximum gas temperature and pressure of the test chamber in spray fires ore greatly changed according to the inlet sodium temperature in the test chamber. The characteristics of the columnar fires were almost similar to those of spray fires, but the maximum temperature and pressure of the test chamber were much smaller even for a large amount of sodium injection. And it was shown in spray and columnar fires that the temperatures at each measurement position in the test chamber were quite different due to the instantaneous sodium oxidation in comparision with pool fires. Finally, the graphex powder was proved to be a very effective extinguisher against sodium pool fires.

  • PDF

안전체험교육이 안전한 사회 문화를 이끌어낸다

  • Yun, Seon-Hwa
    • 방재와보험
    • /
    • s.117
    • /
    • pp.14-19
    • /
    • 2007
  • 제대로 배운 안전교육이, 또한 한 순간의 올바른 교육이 사람의 생명을 살릴 수 있다. 개개인의 생명을 살리고, 사고를 사전에 예방하는 적절한 대안이 바로 안전교육이며, 안전교육은 안전을 생활화하는 사회를 만드는 데 중요한 밑거름이 된다.

  • PDF

Water mist fire suppression (I) -A personal computer fire (미분무수를 이용한 소화실험(I)- 개인용 컴퓨터 화재)

  • 김명배;장용재;한용식;윤명오
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.27-33
    • /
    • 1999
  • Water mist fire suppression experiment is carried out for a personal computer fire. F Fire spread is observed and analyzed by measured temperatures without the injection of t the water mist. The extinguishment test shows that oxygen concentration increases r rapidly upon the water mist injection. Also $C0_2$ concentration decreases steeply due to t the injection because the water mist suppresses combustion reaction. Relative humidity g goes up very steeply by the injection.

  • PDF

Heat Transfer Characteristics on the High Speed Bullet Penetrated a Fuel Tank (고속충격탄의 연료탱크 관통시 열전달 특성)

  • Lee, Seung-Chul;Park, Young-Rok;Jeon, Woo-Chul;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.533-536
    • /
    • 2011
  • 본 연구에서는 차량 연료탱크에 충격탄 관통 시 화재발생 여부를 분석하기 위한 연구의 전단계로서, 충격탄 속도 변화에 따른 연료탱크 내부의 열전달특성을 분석하기 위해 전산유체역학기법을 도입하여 수치해석을 수행한 결과 다음과 같은 결론을 얻었다. 잔류속도 120m/s의 경우, 관통부를 지난 위치에서 최대온도는 약 324.8K를 나타내고 잔류속도 360m/s의 경우, 충격탄이 관통부로 유입되면서 급격하게 증가되어 최고온도 약 382.1K를 나타낸다. 이러한 결과로 미루어 최고 온도가 가솔린 연료의 착화온도보다 높아 화재의 위험성이 있지만 순간적인 온도변화가 심하고 착화시간이 만족되지 않을 것으로 판단된다.

  • PDF

어떻게 살아서 나갈 것인가?

  • Gang, Yeong-Eun
    • 방재와보험
    • /
    • s.110
    • /
    • pp.42-50
    • /
    • 2005
  • 본 자료는 시사주간지 TIME, 2005년 5월 2일 자. " How to Get Out Alive" From hurricanes to 9/11: What the science of evacuation reveals about how humans behave in the worst of times를 번역한 것으로, 기사는 9/11 테러와 같은 극단적인 위기의 순간 오히려 죽음을 재촉하거나 방관하는 인간의 숨겨진 본능적 행동특성에 관한 고찰을 통해, 평소 어떤 자세와 마음가짐을 준비해야 죽음의 공간으로부터 신속하고 효과적으로 살아 나갈 수 있는지에 관한 과학적인 조사연구들을 소개하고 있다.

  • PDF

장애인의 접근성을 위한 규정 및 설계 개념

  • Mun, Sang-Hun
    • 방재와보험
    • /
    • s.121
    • /
    • pp.44-50
    • /
    • 2007
  • 오히려 장애는 우리 모두의 삶에서 어느 특정한 시기와 관련한다. 어떤 이들에게 그것은 일시적일 수 있고, 또 다른 이들에게는 훨씬 더 길 수 있다. 우리 모두가 삶의 어느 순간에 장애인이 될 수 있다. 이것이 우리의 건축 환경과 프로그램에 대하여 다시금 진지하게 생각하고 규정하는 선견지명을 가져야 하는 이유이다.

  • PDF