A correction of synthetic aperture sonar image using the redundant phase center technique and phase gradient autofocus (Redundant phase center 기법과 phase gradient autofocus를 이용한 합성개구소나 영상 보정)

  • Ryue, Jungsoo;Baik, Kyungmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.546-554
    • /
    • 2021
  • In the signal processing of synthetic aperture sonar, it is subject that the platform in which the sensor array is installed moves along the straight line path. In practical operation in underwater, however, the sensor platform will have trajectory disturbances, diverting from the line path. It causes phase errors in measured signals and then produces deteriorated SAS images. In this study, in order to develop towed SAS, as tools to remove the phase errors associated with the trajectory disturbances of the towfish, motion compensation technique using Redundant Phase Center (RPC) and also Phase Gradient Autofocus (PGA) method is investigated. The performances of these two approaches are examined by means of a simulation for SAS system having a sway disturbance.

Dependencies of Group Velocity and Attenuation Coefficient on Structural Properties in Copper and Nickel Foams with an Open-Celled Structure as Trabecular-Bone-Mimicking Phantoms (해면질골 팬텀으로서 개포된 구조를 갖는 구리폼 및 니켈폼에서 구조적 특성에 대한 군속도 및 감쇠계수의 의존성)

  • Kim, Seong-Il;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.158-166
    • /
    • 2011
  • In the present study, copper and nickel foams with an open-celled structure as trabecular-bone-mimicking phantoms were used to investigate the dependencies of group velocity and attenuation coefficient on structural properties such as trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) in trabecular bone. The group velocity and attenuation coefficient of the copper and nickel foams were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. The separation of the Biot's fast and slow waves was consistently observed in the ultrasonic signals transmitted through the copper and nickel foams. The group velocities of the copper and nickel foams showed highly positive correlations with Tb.Th and Tb.Sp. The attenuation coefficient of the copper foam showed a highly negative correlation with Tb.Th and Tb.Sp, whereas that of the nickle foam showed a highly positive correlation with Tb.Th and Tb.Sp. These results advance our understanding of those previously reported by other researchers using trabecular bone samples or phantoms.

Automatic Discharge Measurement Using the Velocity Index Method (유속지수법을 이용한 자동유량측정)

  • Kim, Chi-Young;Kim, Won;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.242-246
    • /
    • 2006
  • 최근 들어 전 세계적으로 유량측정 분야의 큰 변화의 방향은 자동화이다. 전자, 전기 기술과 정보통신 기술의 발달을 유량측정 분야에 적용하여 자동적으로 유량측정을 수행하고 실시간으로 모든 유량자료를 수집하는 시스템을 구성하려는 연구가 활발하게 진행중이다. 최근에 초음파 유량계와 더불어 자동 유량측정 기법으로 각광을 받고 있는 기법이 유속지수법(index velocity method)이다. 유속지수법의 원리는 매우 간단하다. 수위 기록을 통하여 수위-면적 관계로부터 흐름 단면적을 구하고, 임의의 영역에서 측정된 유속이 단면 평균 유속으로 환산될 수 있다면, 흐름 단면적과 평균 유속에 의해 연속적으로 유량을 구할 수 있다. 유속지수법에서 가장 중요한 것이 전체 평균 유속을 대표할 수 있는 유속지수를 정확하고 효율적으로 측정하는 것이다. 유속지수법에 의한 연속 유량측정 목적으로 최근에 ADVM(Acoustic Doppler Velocity Meter)이 개발되어 이용되고 있다. ADVM은 수중에 초음파를 발사해서 산란체에서 반사되어 돌아오는 초음파의 주파수 편이, 즉 도플러 효과를 이용하여 유속을 측정하는 유속계이다. 본 연구에서는 ADVM을 괴산댐 하류에 위치한 시험하천에 설치하여, 유속지수법에 의한 유량측정기법을 적용하고 그 특성을 분석하였다. 유속지수법으로 측정된 유량을 괴산댐 방류량과 비교한 결과 평균 4.0%의 상대오차를 지니고 있어 비교적 정확한 연속 유량측정이 가능한 것으로 나타났다. 이와 같은 유속지수법을 하천 유량측정에 활용하면 보다 정확한 유량을 연속적으로 자동화하여 측정할 수 있을 것으로 기대된다.연계모형의 한계로 인하여 두 모형의 통합모형이 필요하다. 즉, 강우 혹은 월류유량으로 발생한 지표유량 중 일부분이 과부하가 발생하지 않는 유입구 지점을 통과할 때 배수시스템으로 유입되는 것을 고려할 수 있고, 유입된 유량은 배수시스템 내의 흐름에 반영되도록 배수시스템과 침수해석모형을 통합한 모형 개발이 필요하다. 그러기 위해서는 지표면과 배수시스템에 대한 수리학적 관계를 정립하여야 한다. 본 연구에서는 배수시스템 해석 모형과 도시침수해석 모형을 통합하고, 두 모형간의 유량의 전송과정을 수리학적 관계를 고려한 dual-drainage 도시침수해석모형을 개발하였다. 이를 위해 도시지역 배수시스템 해석 모형으로 널리 이용되고 있는 SWMM모형을 이용하여 지표면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기

  • PDF

Acoustic Band Structures in Two-dimensional Phononic Crystals with a Square Lattice in Water (수중에서 정방형 격자를 갖는 2차원 포노닉 크리스탈의 음향 밴드 구조)

  • Kim, Yoon Mi;Lee, Kang Il;Kang, Hwi Suk;Yoon, Suk Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.335-342
    • /
    • 2015
  • Phononic crystals are composite materials consisting of a periodic arrangement of scattering inclusions in a host material. One of the most important properties of phononic crystals is the existence of band gaps, i.e., ranges of frequencies at which acoustic waves cannot propagate through the structure. The present study aims to investigate theoretically and experimentally the acoustic band structures in two-dimensional (2D) phononic crystals consisting of periodic square arrays of stainless steel solid cylinders with a diameter of 1 mm and a lattice constant of 1.5 mm in water. The theoretical dispersion relation that depicts the relationship between the frequency and the wave vector was calculated along the ${\Gamma}X$ direction of the first Brillouin zone using the finite element method to predict the band structures in the 2D phononic crystals. The transmission and the reflection coefficients were measured in the 2D phononic crystals with 1, 3, 5, 7, and 9 layers of stainless steel cylinders stacked in the perpendicular direction to propagation at normal incidence. The theoretical dispersion relation exhibited five band gaps at frequencies below 2 MHz, the first gap appearing around a frequency of 0.5 MHz. The location and the width of the band gaps experimentally observed in the transmission and the reflection coefficients appeared to coincide well with those determined from the theoretical dispersion relation.

Underwater Telemetering by Ultrasonic Multi-Beam Transducer (Multi-Beam 초음파진동자의 수중원격제어에 관한 연구)

  • Choe, Han-Gyu;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This paper described on the availability fo the underwater telemetering by the ulterasonic multi-beam system made as a trial to expand detectable range of the fish school. The ultrasonic multi-beam system consisted of four transducers which reconstructed with the existing net recorder. The experiment for the telemetering carried out in the set net fishing ground. The results obtained are summerized as follows: 1. The detectable distance of a target by the linear arrangement of four transducers increased according to the sea depth and the interval between transducers. 2. When the fish school in the entrance of set net was measured by linear arrangement of transducers it was entered in depth of 2.5~3.5m at near position of leader, and in depth of 3.5~4.5m at near position of door net. 3. The deviations of error between the actual position and the position by transducer in case of the target depth 1m, 1.5m, 2m were 5.9~27.1cm, 3.2~28.9cm, 3.5~25.8cm respectively, and 68.3% probability radius of them were 14.6cm, 17.7cm, 17.0cm respectively. 4. When the fish school in the fish court of set net was measured by plane arrangement of transducer it was entered toward the opposite direction of tide current. 5. The available distance of telemetering by the multi-beam transducer was 1.8km and the telemetering was possible to control everywhere in case of sea depth more than three meters.

  • PDF

Characteristics of Particle Separation in Water Using Lab-Scale Acoustic Standing Wave (실험실 규모의 음향정재파를 이용한 수중의 입자분리 특성)

  • Ahn, Jaehwan;Kang, Sungwon;Ahn, Kwangho;Kim, I tae;Kim, Seog gu;Ahn, Hosang;Lee, Youngsup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.787-791
    • /
    • 2012
  • Characteristics of particle separation in water using labscale acoustic standing wave were studied. Acoustic standing wave is similar to either sound wave or ultrasonic, which makes a constant wave while returning to the origin by reflector. During that time, particulates dispersed in water are collected on the node of wave, where a sound pressure is zero. Acoustic standing wave transducer as of 28.0 kHz and 1.0 MHz were utilized and $6.8{\mu}m$ kaolin and $100.5{\mu}m$ redmud in average diameter were used as experimental materials in water. Once acoustic standing wave are generated in water, water temperature rises by $0.15{\sim}0.20^{\circ}C/min$ due to a sound pressure. Initial concentration of kaolin and redmud were controlled to have same as of 0.1, 0.2, 0.3, 0.4, 0.5 g/L, respectively. Removal efficiency of the turbidity in a reacting chamber after 5 minutes, when acoustic sound wave was formed in most distinct, was measured to have 18.2~56.2% for kaolin and 23.0~53.6% for redmud at 1.0 MHz. Particle separation was not observed at 28.0 kHz.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

Analysis of Tidal Effect in Hangang Bridge by Automatic Discharge Measurement (자동유량측정에 의한 한강대교 조석영향 분석)

  • Lee, Min-Ho;Kim, Chang-Wan;Yoo, Dong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.513-523
    • /
    • 2009
  • The measuring point of the Hangang Bridge affected by tide has some special topographic characteristics due to Nodle Island. Furthermore the submerged weirs located on the upstream and downstream. Therefore flow is separated and joined by Nodle Island. Discharge measurement at the point of the Hangang Bridge is very important, because Hangang Bridge is key station in managing the discharge and flood forecasting. In the past, it was too difficult to measure discharge in tidal conditions. HRFCO(Han River Flood Control Office) installed automatic discharge measurement facilities for solving this problem. Measuring equipments operates and measures discharge every 10 minutes at 2 points(southern and northern section close to Nodle Island), and calculates flow discharge using Chiu's velocity law(Chiu, 1988). In order to verify the results of automatic discharge measurements, manual discharge measurements were carried out by ADCP. In addition, the monthly discharge were also compared.

Variation of the Incident Sound Level at the Underwater Target`s Position due to Roll Motion of the Ship (선체의 횡요로 인한 수중물표입사음압의 변동에 관하여)

  • Park, Jung-Hui;Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.2
    • /
    • pp.106-110
    • /
    • 1983
  • As the first step to investigate the effect of ship's motion when detecting target with an echo sounder, variations in the incident sound level at the optional position within the sound beam due to roll motion of the transmitter have been measured and calculated. In this experiment, the transmitter (75 KHz) was mounted to the bottom of a FRP model of the 2,275 G. T. stern trawler and the receiver (75 KHz) was installed at each measuring point within the transmitter's beam. Then, the incident sound level was measured for the roll angles from the free roll test on the model ship. For a range of roll angle of $\pm$20$^{\circ}$from the vertical, the measuring values of the incident sound level at each measuring point were rapidly fluctuated from 12.9% to 78.1 depending on the roll angle, and agreed well with the caculated ones. Consquently, we concluded that the effect of ship's motion when detecting target with an echo sounder should be sufficiently considered.

  • PDF

Analysis of the risk of further oil spill from Sunken lanker, 'Kyung-Shin' (침몰 유조선 경신호의 추가 해양오염 가능성에 관한 연구)

  • Choi Hyuek-Jin;Byun Sung-Hoon;Lee Moon-Jin;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.4
    • /
    • pp.63-73
    • /
    • 2002
  • This paper presents the results of a ten-day long survey for assessing the possibility of further oil spillage from the sunken tanker, Kyung-Shin(995 G/T), which had sunken in the East Sea, off Pohang City, in February 1988. The survey was conducted using remotely operated vehicle(ROV), manned submersible and ultrasonic thickness gauge in September 2001. The external inspection by the optical camera shows that small scale oil spill has been continued from the sunken ship. It's hull thickness was also measured at several points of the ship, using an ultrasonic sensor for assessing the current corrosion status of the sunken ship. Taking into account the results of this survey and the existing salvage report, it is estimated that the remaining oil in the tanker is approximately 600 ㎘, and this oil could be leaked into marine environment due to continuous severe corrosion if no preventive is taken.

  • PDF