• Title/Summary/Keyword: 속도상수

Search Result 1,219, Processing Time 0.029 seconds

Fluorescence Quenching of Coumarin Laser Dyes by N,N-dimethylaniline (N,N-dimethylaniline에 의한 Coumarin 색소분자의 형광 소광)

  • Park, Guk Hee;Kang, Tai Jong
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.1
    • /
    • pp.22-27
    • /
    • 1998
  • Fluorescence quenching of coumarin 153 and coumarin 481 with N,N-dimethylaniline in various solvents was investigated. Quenching rate constants are related to diffusion-limited rate constants to some extent. It is noted that smaller discrepancy was observed between the diffusion-limited rate constant and the experimental quenching rate constant when the stick boundary condition rather than the slip boundary condition was applied for estimating the diffusion coefficients. In nonpolar solvent like cyclohexane fluorescence quenching is adequately explained by the diffusion controlled process within the experimental error, but in acetonitrile the quenching rate constant was estimated to be consistently smaller than the diffusion limited rate constant. This may suggest that fluorescence quenching of coumarin dyes be affected not only by the molecular diffusion but also by the intramoleccular process such as charge separation.

  • PDF

Effects of Phosphorus Doping Concentration on the Oxidation Kinetics of Tungster Polycide ($\Pi$) (텅스텐 폴리사이드의 산화반응속도에 미치는 인 도핑 농도의 영향 $\Pi$)

  • 이종무;한석빈;임호빈;이종길
    • Electrical & Electronic Materials
    • /
    • v.4 no.2
    • /
    • pp.97-104
    • /
    • 1991
  • W/Si의 조성비가 2.6인 CVD텅스텐 실리사이드를 어닐링처리 하지 않고 바로 wet oxidation하여 polycide구조에서 다결정 실리콘 내의 인의 농도가 실리사이드의 산화반응 속도에 미치는 영향을 조사하여 직선-포물선적 속도법칙을 토대로 하여 분석 조사하였다. 텅스텐 실리사이드의 산화속도는 다결정 실리콘 내의 도편트 인의 농도가 증가함에 따라 증가하는 것으로 나타났다. 직선적 속도상수와 포물선적 속도상수 모두 인의 농도가 증가함에 따라 증가하는 경향을 보였다. 직선적 속도상수에 대한 활성화 에너지는 인의 농도가 증가함에 따라 감소하였으나 포물선적 속도상수에 대한 활성화 에너지는 인 농도와 무관한 것으로 나타났다.

  • PDF

The Adaptive Least Mean Square Algorithm Using Several Step Size for Multiuser Detection (다중 사용자 신호 검출을 위한 여러 개의 적응 상수를 사용한 적응 최소 평균 자승 알고리즘에 관한 연구)

  • 최병구;박용완
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.12A
    • /
    • pp.1781-1786
    • /
    • 2000
  • 본 논문에서는, 적응 간섭 제거기(AIC : adaptive interference canceller)에 사용되는 적응 알고리즘 중 계산량이 적고, 하드웨어적 복잡성이 낮은 최소 평균 자승(LMS)알고리즘의 적응화 상수(constant step size)를 여러 개 사용하여 빠른 수렴 속도와 낮은 평균 자승 에러를 가지는 방법을 제안한다. 최소 평균 자승 알고리즘에서 적응화 상수는 수렴속도와 평균 자승 에러를 제거하는데, 적응화 상수가 증가할수록 수렴속도가 빨라지는 반면, 평균 자승 에러는 증가하게 된다. 이 논문에서는 수렴속도를 증가하는 동시에 평균 자승 에러를 줄이기 위해, 최소 평균 자승 알고리즘에서 세 개의 적응화 상수를 가지는 새로운 검출기를 제안한다. 이 구조에서, 매 반복횟수에 따른 각 그룹 출력 값들을 가지고, 선택(selection)부분에서 평균 자승 에러들을 비교하며, 가장 작은 평균 자승 에러를 나타내는 그룹의 에러 값과 필터 계수 값들이 선택되어져 여러 적응화 상수 최소 평균 자승 알고리즘(several step size LMS algorithm)부분에서 각 그룹의 필터 계수를 갱신하는데 필요한 정보로 이용된다.

  • PDF

Change of Velocity Profile due to Introduction of Suspended-Sediment Particles in Turbulent Open-Channel Flow (부유사 입자에 의한 개수로 난류 유속 분포의 변화)

  • Yu, Kwon-Kyu;Yoon, Byung-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.357-361
    • /
    • 2005
  • 부유사 입자를 난류 흐름 중에 투입하면 유속의 연직 분포를 다소간 변화시키는 것으로 알려져 왔다. 1946년에 Vanoni가 Karman 상수의 감소를 제안한 이후 이것은 상당한 논쟁을 불러 왔다. 본 연구에서는 입자 추적유속계(PTV)를 이용하여 개수로 중의 난류와 유사의 속도를 직접 측정하고, 이 자료를 분석하여 부유사 입자가 개수로 난류의 유속 분포에 어떻게 영향을 미치는 가를 구명하였다. 또한 기존의 연구의 측정 자료들과 그들의 주장을 재검토하였다. 분석 결과 부유사 입자는 Karman 상수를 다소 감소시키는 것으로 나타났다. 이 감소 현상은 물과 유사의 상대적인 속도 분포로 설명할 수 있다. 다만 Karman상수의 감소 정도는 종래의 연구자들이 주장한 것보다 상당히 작다. 이처럼 차이가 나는 이유는 종래의 연구들이 Karman 상수의 산정 방법이나 이용한 자료의 선택에서 문제가 있었기 때문이다. 또한, 난류 중에 투입된 부유사는 마찰 속도에는 그다지 영향을 미치지 않는 것으로 나타났다.

  • PDF

Evaluation of the Oxidation of the Carbon Fibers by Normalized Rate Equation (표준화 반응식을 이용한 탄소섬유의 산화반응 해석)

  • 노재승
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.239-239
    • /
    • 2003
  • 탄소재료의 산화반응을 설명한 대부분의 논문은 TGA(Thermo Gravimetric Analysis)를 이용한 연구이다. TGA 장치는 가열이 필요한 물질의 반응연구에 다양하게 이용되고 있는데, 온도에 대한 무게 변화를 간편하게 알 수 있다는 장점과 함께 보편적으로 편리한 Arrhenius형태의 속도식으로 해석된다. 많은 연구자들은 TGA를 이용하여 다양한 탄소재료에 대한 반응속도상수를 구하였으며, 반응기체, 반응온도 및 원료물질에 따라 다른 속도를 나타내는 실험결과를 표준화된 속도식으로 표현하고자 하는 노력이 있었다. 그러나 이런 대부분의 연구는 coal 등과 같은 탄소재료의 연소특성을 이용하려는 에너지 변환 연구가 주를 이루어 왔으며, 탄소섬유의 산화반응에 대한 표준화 식으로 해석한 보고는 거의 없는 실정이다. 이 연구에서는 내부구조가 현격하게 차이나는 다른 두 종류의 피치계 탄소섬유를 TGA를 이용하여 등온 산화반응 시켰다. 반응기체의 종류와 반응온도를 변화시켜 산화반응조건에 따른 중량변화를 관찰하였고, 여러 산화조건에서 얻어진 산화속도를 Kasaoka 등에 의해 제안된 표준화식을 이용하여 산화반응의 평균 속도상수 K와 전환율이 0.5일 때의 속도상수 $k_{f=0.5}$ 결과를 비교하여 산화 반응속도를 정량적으로 해석하고자 하였다.다.

  • PDF

Kinetics of 125I-BSA Binding to Monoclonal Anti-BSA Immobilized on $0.5{\mu}m$ Polystyrene Beads (c크기의 폴리스타이렌 담체에 고정화된 단세포군 항체와 항원 BSA의 속도론)

  • ;Dan
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.225-237
    • /
    • 1996
  • Intrinsic binding kinetics of of 125I-bovine serum albumin (125I-BSA) and immobilized monoclonal anti-BSA (MAb 9.1) were studied. Small non-porous polystyrene beads (0.5${\mu}$m diameter) were used as a solid support to minimize the mass transfer interference on rate measurements. We demonstrated both theoretically and experimentally that the binding reaction is kinetically controlled. Rate measurements show that the association reaction is of second order and the dissociation reaction is of first order. Between 4 and $37^{\circ}C$ the measured equilibrium constant agrees well with the equilibrium constant calculated from the rate measurements. The temperature effects on association are much greater than on dissociation; the activation energy for association is about 9Kca1/mole, as compared to 2Kca1/mole for dissociation. The use of small non-porous beads as a solid support in binding studies essentially avoids mass transfer limitations; such a system makes it possible to determine the intrinsic binding characteristics of any immobilized antibody on a solid surface.

  • PDF

Solvent Effect on the Nucleophilic Substitution Reaction of Naphthalene Sulfonyl Chloride with Pyridine (염화나프탈렌술포닐과 피리딘의 친핵성 치환반응에 대한 용매효과)

  • Ikchoon Lee;Tae Seop Uhm;Dae Dong Sung;Geol Yeom
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 1983
  • Solvent effects on nucleophilic substitution reaction of naphthalene sulfonyl chlorides with pyridine in protic and aprotic solvent have been studied by means of conductometry. Results showed that the rate constants increased with dielectric constants for protic solvents, while they decreased with dielectric constants for aprotic solvents, except for acetonitrile which has a higher dielectric constant but had also greater rate constant. The rate constants were shown to be more susceptible to polarity-polarizability parameter, , than to hydrogen bond donor acidity parameter, ${\alpha}$, indicating that the pulling effect of hydrogen bonding solvent.

  • PDF

Design and Implementation of Lok-up Table for Pre-scaling in Very-High Radix Divider (높은 자릿수 나눗셈 연산기에서의 영역변환상수를 위한 검색테이블 설계 및 구현)

  • 이병석;송문식;이정아
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.3-5
    • /
    • 1999
  • 나눗셈 알고리즘은 다른 덧셈이나 곱셈 알고리즘에 비해 복잡하고, 수행 빈도수가 적다는 이유로 그동안 고속 나눗셈의 하드웨어 연구는 활발하지 않았다. 그러나 멀티미디어의 발전 및 고성능의 그래픽 랜더링을 위한 보다 빠른 부동소수점연산기(FPU)가 필요하게 되었으며, 이에 따라서 고속의 나눗셈 연산기의 필요성이 증가하게 되었다. 특히, 전체의 수행 시간 향상을 위해서라도 고속 나눗셈 연산기의 중용성은 더욱 부각되고 있다. 그러나 고속 나눗셈 연산기는 연산 속도와 크기라는 서로 상반되는 요소를 가지고 있다. 즉, 연산 속도가 빠르면 크기는 늘어나고, 크기를 줄이면 연산 속도는 늦어지게 된다. 본 논문은 높은 자릿수(Very-High Radix) 나눗셈 알고리즘에서 영역변환상수를 구하는 방법으로 연산이 아닌 검색테이블(Look-up Table)을 이용한다. 그리고 검색테이블의 크기를 줄이는 방법으로 영역변환상수의 범위 분석 및 캐리 저장형을 이용한 검색테이블 분할 방법을 이용하였다. 전체적으로는 영역변환상수를 구하는 연산주기가 필요없게 되므로 나눗셈 연산기의 영역 크기의 변화가 적으면서 연산 속도는 빨라졌음을 알 수 있다.

  • PDF

Kinetics of Pyrolysis Degradation of Cured Phenol Resin (SC-1008) (I). (경화된 페놀 수지 (SC-1008)의 열분해 반응에 관한 연구(I).)

  • 김연철;강희철;예병한;배주찬
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.137-144
    • /
    • 1996
  • The kinetic coefficients far decomposition of the cured phenol resin (SC-1008) using a modified Arrhenius relationship have been determined from thermogavimetric analyses (TGA). The kinetic parameters were determined by multiple heating rate technique developed by Freideman and Henderson. Weight loss (decomposition) and weight loss rate (decomposition rate)were measured and recorded for three heating rates; $5^{\circ}C$/min ,$10^{\circ}C$/min, and $20^{\circ}C$/min. Relatively good agreement was obtained between measured and calculated decomposition as a function of temperature. By separating the reaction, the reaction order and pre exponential factor become empirical parameters which provide a "best fit" of the data. However, this method yields an extremely accurate reproduction of the thermograms over a wide range of heating rates. This is the desired result for kinetic parameters used in thermal models.al models.

  • PDF

The Effects of Charge Transfer Complex on the Reaction of Aniline and Iodine (Aniline과 Iodine간의 반응에 있어서 전하이동 착물의 영향)

  • Oh-Yun Kwon;U-Hyon Paek;Eung-Ryul Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.174-179
    • /
    • 1992
  • Reaction of aniline and iodine in$CHCl_3,\;CH_2Cl_2 : CHCl_3$(1 : 1), and $CH_2Cl_2$ has been studied kinetically by using conductivity method, Pseudo first-order rate constants ($k_{obs}$) and second-order rate constants ($k_{obs}$/[aniline]) are dependent on the aniline concentration. Second-order rate constants obtained were increased with increasing aniline concentration. We analysed these results on the basis of formation of charge transfer complex as reaction intermediate. From the construction of react ion scheme and derivation of rate equation, we calculated equilibrium constants and activation parameters for the formation and transformation of charge transfer complex. The equilibrium constants were decreased by an increase in the dielectric constant of the solvent and the value is 1.7-3.7$M^{-1}$. The rate of transformation are markedly affected by the solvent polarity. ${\Delta}H^{\neq}$ is about 14.2kJ/mol, and ${\Delta}S^{\neq}$ is large negative value of -243J/mol K.

  • PDF