• Title/Summary/Keyword: 삽입구

Search Result 337, Processing Time 0.026 seconds

Preparation of Exfoliated PCL/Clay Nanocomposite and Its Characterization (박리형 PCL/Clay 나노복합재료 제조와 특성)

  • 유성구;박대연;배광수;서길수
    • Polymer(Korea)
    • /
    • v.25 no.3
    • /
    • pp.421-426
    • /
    • 2001
  • 11-Aminododecanoic acid, to insert the functional group of -COOH reacted with the end group of poly($\varepsilon$-caprolactone) diol, and cetyltrimethylammonium bromide (CTMA), to increase the d-spacing of Montmorillonite (MMT), were intercalated into $Na^+;_-$MMT. The modified MMT was reacted with poly(${varepsilon}-caprolactone$) diol ($M_n{=2000$) in THF solution at $80^{\circ}C$ for 4 hrs. After reaction, poly(${varepsilon}-caprolactone$) ($M_n{=80000$) was mixed into the solution for 12 hrs. To prepare the PCL/clay nanocomposite film this solution was cast into the silicon mold at $60^{\circ}C$ in vacuum oven for 6 hrs. From the results of XRD and TEM, it was found that the exfoliated PCL/clay nanocomposite were prepared. The effects of the amount of MMT on the mechanical properties and thermal properties of PCL/clay nanocomposites have been investigated by tensile tester and DSC. Because the MMT was dispersed homogeneously in PCL matrix, the Young's modulus of the nanocomposite were found to be excellent. However, MMT dispersed in PCL matrix had almost no effect on the tensile strength of the composites. The crystallization temperature of PCL increased in proportion to 3 wt% MMT in the PCL matrix.

  • PDF

Genetic Analysis of Caulobuter crescentus by Using Transposon Tn5 and Reverse Field Electrophoresis (Transposon Tn5 및 Reverse Field Electrophoresis를 이용한 Caulobuter crescentus의 유전자 분석 연구)

  • 구본성;버트일리
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.183-187
    • /
    • 1989
  • The bacteriophage Mu and transposon Tn5 containing plasmid pJB4JI-transferred transposon Tn5 to Caulobuter crescentus. When several thousand of transposon Tn5 insertion mutants were examined, we found auxotrophic and motility mutants at frequencies of 2% and 3%, respectively. Transposition of transposon Tn5 was analyzed by the reverse field electrophoresis and Southern hybridization. The results indicated that transposon Tn5 was randomly inserted to Caulobuter crescentus chromosome but the plasmid vector, pJB4JI, was not maintained.

  • PDF

Dual-Band Compact Broad Band-Pass Filter with Parallel Coupled Line (평행 결합 선로를 갖는 이중 대역의 소형 광대역 대역 통과 필터의 설계)

  • Choi, Young-Gu;Shrestha, Bhanu;Yoon, Ki-Cheol;Lee, Jeong-Hun;Hong, Tae-Ui
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1423-1431
    • /
    • 2010
  • In this paper, the dual-band compact broad bandpass filter using parallel coupled line is proposed. The proposed filter has reduced size and can be controlled bandwidth. And it is also possible to operate in the dual-band purpose. Futhermore, the inserted bandstop fiilter with T-type configuration is also possible to operate in the same purpose. The dual-band bandpass filter has the first operating frequencies and its bandwidth which are 5.8 GHz and 60 % respectively and the second operating frequency and the bandwidth are 16.2 GHz and 60 % respectively. The insertion loss and the return loss of the first frequency has 0.4 dB and 17.4 dB and the insertion loss and the return loss of the second frequency has 0.62 dB and 19.8 dB, respectively.

Exchange Bias Field and Coercivity of [NiFe/NiFeCuMo/NiFe]/FeMn Multilayers ([NiFe/NiFeCuMo/NiFe]/FeMn 다층박막의 교환결합력과 보자력에 관한 특성 연구)

  • Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.4
    • /
    • pp.132-135
    • /
    • 2011
  • The exchange bias field ($H_{EX}$) and the coercivity ($H_C$) variation and change depending on the thickness of intermediately super-soft magnetic NiFeCuMo layer with different thickness of the bottom NiFe layer were investigated. The $H_{EX}$ of triple pinned NiFe(4 nm)/NiFeCuMo($t_{NiFeCuMo}$= 1 nm)/NiFe(4 nm)/FeMn multilayer has the maximum value more less than one of single pinned NiFe(8 nm)/FeMn layer. If NiFeCuMo layer is inserted each into between the pinned and free NiFe layers, we can be used as GMR-SV device for a bio-sensor that has improved magnetic sensitivity.

A Computation of the Resonant Frequencies using Contour Graph Method in the Dielectric-disc Loaded Cylindrical Cavity Resonators (유전체 디스크가 삽입된 원통형 공동 공진기에서 Contour Graph 방법을 이용한 공진주파수 계산)

  • Choi, Hong-Ju;Lee, Won-Hui;Hur, Jung;Choi, Gwang-Je;Lee, Sang-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1420-1427
    • /
    • 2000
  • We described a method to obtain electromagnetic solution and resonant frequencies in dielectric-disc loaded cylindrical cavity resonators. Resonant frequency of dielectric-disc loaded cylindrical cavity resonators is calculated by analyzing the characteristic equation. The characteristic equation is solved by using the ContourPlot graph of Mathematica. As increasing to height of cavity, we compare the calculated resonant frequency with experimental frequency. The calculated results well agree with the experimental ones. The error between them is 0.2% or 1.6% for the case of the top plate is close to or far from concentric dielectric-disc, respectively.

  • PDF

A Watermarking Method Based on the Informed Coding and Embedding Using Trellis Code and Entropy Masking (Trellis 부호 및 엔트로피 마스킹을 이용한 정보부호화 기반 워터마킹)

  • Lee, Jeong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2677-2684
    • /
    • 2009
  • In this paper, we study a watermarking method based on the informed coding and embedding by means of trellis code and entropy masking. An image is divided as $8{\times}8$ block with no overlapping and the discrete cosine transform(DCT) is applied to each block. Then the 16 medium-frequency AC terms of each block are extracted. Next it is compared with gaussian random vectors having zero mean and unit variance. As these processing, the embedding vectors with minimum value of linear combination between linear correlation and Watson distance can be obtained by Viterbi algorithm at each stage of trellis coding. For considering the image characteristics, we apply different weight value between the linear correlation and the Watson distance using the entropy masking. To evaluate the performance of proposed method, the average bit error rate of watermark message is calculated from different several images. By the experiments the proposed method is improved in terms of the average bit error rate.

Video Fingerprinting System through Zero-based Code Modulation Technique (제로기반 코드 변조 기법을 통한 비디오 핑거프린팅 시스템)

  • Choi Sun Young;Lee Hae-Yeoun;Kang In Koo;Lee Heung-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.12B no.4 s.100
    • /
    • pp.443-450
    • /
    • 2005
  • Digital fingerprinting is a contents-protection technique, where customer information is inserted into digital contents. Fingerprinted contents undergo various attacks. Especially, attackers can remove easily the inserted fingerprint by collusion attacks, because digital fingerprinting inserts slightly different codes according to the customers. Among collusion attacks, averaging attack is a simple, fast, and efficient attack. In this paper, we propose a video fingerprinting system that is robust to the averaging attack. In order to achieve code efficiency and robustness against the averaging attack, we adopt anti-collusion code (fingerprint code) from GD-PBIBD theory. When the number of users is increased, the size of fingerprint code also grows. Thus, this paper addresses a zero-based code modulation technique to embed and detect this fingerprint code efficiently. We implemented a blind video fingerprinting system based on our proposed technique and performed experiments on various colluding cases. Based on the results, we could detect most of colluders. In the worst case, our scheme could trace at least one colluder successfully.

Application of the Total Artificial Heart as an Implantable Biventricular Assist Device by Left Thoracotomy in an Ovine Model (양에서 좌측 개흉술 하에 완전인공심장의 체내이식형 양심실 보조장치로 사용에 관한 연구)

  • 원태희;민병구;김원곤
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.296-304
    • /
    • 2001
  • 배경: 이번 연구의 목적은 체내이식형 양심실 보조장치의 개발을 위한 안전하고 간편한 동물실험 모델을 확립하는 것이며 이동작동형 완전 인공심장의 양심실 보조장치로의 사용 가능성을 알아보는 것이다. 대상 및 방법: 7마리의 Corridale 양을 대상으로 실험하였다. 5번째 늑간극을 통하여 좌측 개흉술을 시행하고 좌측 유출로 캐뉼라는 하행 대동맥에 Dacron graft을 사용하여 연결하였고 유입로 캐뉼라는 좌심방에 삽입하였다. 우측 유출로 캐뉼라는 하행 대동맥과 같은 방법으로 주폐동맥에 연결하였으며 유입로 캐뉼라는 혜동맥을 하방으로 젖혀 우심방이를 노출시킨 다음 우심방이에 삽입하였다. 4마리에 있어서는 양심실 보조장치를 전복막강(preperitoneal space)에 위치시켰으며 2마리에 촤측흉강 내에, 1마리에서는 외부에 위치시켰다. aPTT는 수술전 aPTT의 2∼2.5배로 맞추어 주었다 결과: 수술중 또는 수술직후 사망한 경우는 없었으며 7마리 모두 인공호흡기 이탈이 가능하였고 스스로 기립하고 음식물 섭취도 가능하였다. 1마리는 술후 2일째 혈전 색전증 및 인공호흡기 작동 잘못으로 사망하였으며 2마리의 겨우는 술후 2일째 각각 양심실 보조장치의 작동 잘못 및 호흡부전으로 사망하였고, 3마리의 경우는 술후 4일째 혈전색전증으로 인한 급성신부전 및 호흡부전 등으로 사망하였다. 1마리에 있어서는 28일간 생존하였으며 양심실 보조장치의 구동 장치에 연결된 라인의 마로로 인해 양심실 보조장치의 작동이 정지되었으나 바로 양심실 보조장치를 제거하고 살릴 수 있었다. 모든 경우에 있는 캐뉼라를 삽입하고 양심실 보조장치를 작동시키는데 큰 어려움이 없었다. 7마리 중 4마리에서 혈전이 발견되었으며 특히 판막을 연결한 부위에 혈전생성이 많았다. 그러나 캐뉼라에는 혈전생성이 없었다. 결론: 양에 있어서 좌측 개흉술 및 전복막강 공간에 양심실 보조장치를 위치시키는 이번 동물실험 모델은 체내 이식형 양심실 보조장치 개발을 위한 좋은 동물실험 모델이라고 생각된다. 또한 디동 작동기형 완전 인공심장의 혈전생성을 억제할수 있는 방법들의 연구개발이 지속된다면 장기간의 체내 이식형 양심실 보조장치로 사용할 수 있을 것으로 생각된다.

  • PDF

A Study on the Polymer Nanocomposite for Corrosion Protection (내식 방지용 고분자 나노복합재료에 관한 연구)

  • Lyu, Sung Gyu;Park, Se Hyeong;Park, Chan Sup;Cha, Jong Hyun;Sur, Gil Soo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.212-216
    • /
    • 2005
  • Benzotriazole which is used as a corrosion inhibitor for the zinc coated steel was intercalated into Na-MMT. X-ray diffraction experiments on intercalant/silicate composite samples demonstrated that the intercalation of intercalant leads to an increase in the spacing between silicate layers. Water soluble poly(ethylene-co-acrylic acid) (PEA) nanocomposites, to use as a coating agent, were prepared with these modified MMT. We found that mono-layered silicates were dispersed in PEA matrix and those resultants were exfoliated nanocomposites. From the result of salt spray test, we found that this coating agent prepared with water soluble poly(ethylene-co-acrylic acid) (PEA) nanocomposite provided good corrosion protection. These results were caused by decreasing the rate of oxygen permeation from silicate layers dispersed homogeneously in PEA matrix and the effect of corrosion inhibitor from benzotriazole.

Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study (토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험)

  • Daegun, Kim;Jaehong, Jung;Sungchul, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.709-718
    • /
    • 2022
  • We evaluated the effect of high-density aluminum, titanium, and steel metal inserts on computed tomography (CT) numbers and radiation treatment plans for Tomotherapy. CT images were obtained using a cylindrical TomoPhantom comprising cylindrical rods of various densities and metal inserts. Three CT image sets were evaluated for image quality as the mean CT number and standard deviation. Dose evaluation also performed. The reference values did not significantly differ between the CT image sets with the corrected metal inserts. The higher-density material exhibited the largest difference in the mean CT number and standard deviation. The conformity index at Iterative-Metal Artifact Reduction (iMAR) was approximately 20% better than that of non-iMAR. No significant target or organ at risk dose difference was observed between non-iMAR and iMAR. Therefore, iMAR is helpful for target or organ at risk delineation and for reducing uncertainty for three-dimensional conformal radiation therapy in Tomotherapy.