• Title/Summary/Keyword: 삼중압

Search Result 9, Processing Time 0.031 seconds

Thermal Design Analysis of Triple-Pressure Heat Recovery Steam Generator and Steam Turbine Systems (삼중압 열회수 증기발생기와 중기터빈 시스템의 열설계 해석)

  • Kim, Dong-Seop;Lee, Bong-Ryeol;No, Seung-Tak;Sin, Heung-Tae;Jeon, Yong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.507-514
    • /
    • 2002
  • A computation routine, capable of performing thermal design analysis of the triple-pressure bottoming system (heat recovery steam generator and steam turbine) of combined cycle power plants, is developed. It is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. It can be applied to various parametric analyses including optimized design calculation. This paper presents analysis results for the effects on the design performance of heat exchanger arrangements at intermediate and high temperature parts as well as steam pressures. Also examined is the effect of steam sources for deaeration on design performance.

Prediction of Vapor Pressure of Parahydrogen from the Triple to the Critical Point (삼중점과 임계점간 파라수소의 증기압 예측)

  • Chung, Jaygwan G.
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.4
    • /
    • pp.293-297
    • /
    • 2001
  • The existing vapor pressure measurements reported in the literature for parahydrogen between the triple point and the critical point have been employed to establish the constants and exponent of the following equation in the form of reduced vapor pressure and reduced temperature: ln $lnP_r=2.64-{\frac{2.75}{T_r}}+1.48129lnT_r+0.11T^5_r$Only the normal boiling point ($T_b$= 20.268K), the critical pressure ($P_c$= 1292.81 kPa), and the critical temperature ($T_c$= 32.976K) are necessary to calculate the vapor pressure for an overall average deviation of 0.21% for 153 experimental vapor pressure data.

  • PDF

A Study on Shield ring Design for Relieved Electric Field Intensity in GIS Spacer Triple Junction (GIS 스페이서 삼중점 전계 완화를 위한 쉴드링 설계에 관한 연구)

  • Kwon, Gumin;Lee, Seungkwan;Kang, Mincheol;Jeong, Kyengsik;Kim, Kyonghoe
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1181-1182
    • /
    • 2015
  • 본 논문에서는 초고압 가스절연개폐장치(GIS, Gas Insulated Switchgear) 내 고체 절연물인 스페이서에서 삼중점의 전계를 완화하기 위한 쉴드링 설계 방법과 그에 따른 효과를 분석하였다. 이를 위해 420kV GIS 스페이서를 축대칭 모델로 단순화하여 전계해석을 수행하였으며, 쉴드링 직경에 따른 삼중점 전계세기 변화를 확인하였다. 또한 쉴드링과 스페이서 계면 사이의 최소 이격거리를 계산하여 쉴드링의 최적 직경을 구하였다. 추가적으로, 새로운 설계 기법인 Double 쉴드링 기법을 소개하고 기존의 쉴드링이 하나인 경우와 비교 분석하여 그 효과를 확인하였다.

  • PDF

Performance Design Analysis of the Bottoming System of Combined Cycle Power Plants (복합화력발전 하부시스템의 성능설계해석)

  • Lee, B.R.;Kim, T.S.;Ro, S.T.;Shin, H.T.;Jeon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.738-743
    • /
    • 2001
  • A computer program, capable of performing thermal design analysis of the triple pressure bottoming system of combined cycle power plants, was developed. The program is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. The program is applicable to various parametric analyses including optimized design calculation. This paper presents examples of analysis results for the effects of arrangement of heat exchanger units, steam pressures and deaerating sources on design performance indices such as steam turbine power and the size of heat recovery steam generator.

  • PDF

The Generation of Vacuum Scale Using the Vapour Pressure of Water (물의 증기압을 이용한 진공도눈금의 생성)

  • Seong D. J.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.180-185
    • /
    • 2005
  • The possibility of generation of the vacuum scale using the vapour pressure of water was evaluated. The range of vacuum from 3.3 kPa to 101.3 kPa was corresponds the vapour pressure of water in the temperature range from $25^{\circ}C$ to $100^{\circ}C$ The measured values of the vapour pressure of water were agreed within the deviation of $5\%$ comparing to reference value. This result shows the vapour pressure of water can be used as an secondary reference of the vacuum scale. Moreover it shows the thermo-dynamical properties such as, triple point, temperature-pressure curve of a material have a applicability in the vacuum scale as a reference in corresponding range of vacuum.

Veriations of Carbon Dioxide Concentration in a Strawberry Greenhouse Using Dry ice (드라이아이스를 이용한 딸기재배 온실의 이산화탄소 농도변화)

  • Paek, Yee;Kang, Suk-Won;Jang, Jae-Kyung;Kwon, Jin-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.182-188
    • /
    • 2020
  • This study aimed to collect the carbon dioxide generated as a by-product from petrochemicals and liquor factories and use it in a crop breeding greenhouse. This was applied mainly to the storage of dry ice and the supply of carbon dioxide to achieve this target. Dry ice has a strong cooling effect because CO2 becomes a solid or gas at temperatures and pressures below the triple point, and the solid sublimes at -78.5℃ and atmospheric pressure. The consumption of dry ice according to temperature was 0.983kg/day, 2.358kg/day, 5.102kg/day, and 7.035kg/day when the temperature was 5℃, 10℃, 15℃, and 20℃, respectively, which corresponded to 1,102ppm, 1,481ppm, 1,677ppm, and 1,855ppm. Dry ice consumption in the test greenhouse decreased by approximately 0.9kg/h, and the CO2 concentration in the greenhouse at 9 a.m., before supplying dry ice increased to 517ppm, 1,519ppm at 10 a.m., 1,651ppm at 11 a.m., and 1,651ppm at 12 p.m., before maintaining this level of activity. Overall, this study attempted to contribute to increasing farm income by deriving the supply conditions through an expansion of the supply of carbon dioxide gas for crops.

Hydraulic-Thermal-Mechanical Properties and Radionuclide Release-Retarding Capacity of Kyungju Bentonite (경주 벤토나이트의 수리-열-역학적 특성 및 핵종 유출 저지능)

  • Jae-Owan Lee;Won-Jin Cho;Pil-Soo Hahn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • Studies were conducted to select the candidate buffer material for a high-level waste (HLW) repository in Korea. This paper presents the hydraulic properties, the swelling properties, the thermal properties, and the mechanical properties as well as the radionuclide release-retarding capacity of Kyungju bentonite as part of those studies. Experimental results showed that the hydraulic conductivities of the compacted bentonite were very low and less than $10^{-11}$m/s. The values decreased with increasing the dry density of the compacted bentonite. The swelling pressures were in the range of 0.66 MPa to 14.4 ㎫ and they increased with increasing the dry density. The thermal conductivities were in the range of 0.80 ㎉/m $h^{\circ}C$ to 1.52 ㎉/m $h^{\circ}C$. The unconfined compressive strength, Young's modulus and Poison's ratio showed the range of 0.55 ㎫ to 8.83 ㎫, 59 ㎫ to 1275 ㎫, and 0.05 to 0.20, respectively, when the dry densities of the compacted bentonite were 1.4 Ms/㎥ to 1.8 Mg/㎥. The diffusion coefficients in the compacted bentonite were measured under an oxidizing condition. The values were $1.7{\times}10^{-10}$m^2$/s to 3.4{\times}10^{-10}$m^2$/s for electrically neutral tritium (H-3), 8.6{\times}10^{-14}$m^2$/s to 1.3{\times}10^{-12}$m^2$/s for cations (Cs, Sr, Ni), 1.2{\times}10^{-11}$m^2$/s to 9.5{\times}10^{-11}$m^2$/s for anions (I, Tc), and 3.0{\times}10^{-14} $m^2$/s to 1.8{\times}10^{-13}$m^2$/s $for actinides (U, Am), when tile dry densities were in the range of 1.2 Mg/㎥ to 1.8 Mg/㎥. The obtained results will be used in assessing the barrier properties of Kyungju bentonite as a buffer material of a repository in Korea.n Korea.

  • PDF

Development and validation of an analytical method for nematicide imicyafos determination in agricultural products by HPLC-UVD (HPLC-UVD를 이용한 살선충제 imicyafos의 시험법 개발 및 검증)

  • Do, Jung-Ah;Park, Hyejin;Kwon, Ji-Eun;Choi, Won-Jo;Lee, Hyun-Sook;Chang, Moon-Ik;Hong, Jin-Hwan;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.234-242
    • /
    • 2014
  • Imicyafos which is a nematicide for controlling root-knot nematodes has been registered in the Republic of Korea in 2012, and the maximum residue limits of imicyafos are set to watermelon and korean melon as each 0.05 mg/kg. Extremely reliable and sensitive analytical method is required for ensuring food safety on imicyafos residues in agricultural commodities. Imicyafos residues in samples were extracted with acetone, partitioned with hexane and dichloromethane, and then purified with florisil. The purified samples were analyzed by HPLC-UVD and confirmed with LC-MS. Linear range was between 0.1~5 mg/kg with the correlation coefficient ($r^2$) 0.99997. Average recoveries of imicyafos ranged from 77.0 to 115.4% at the spiked levels of 0.02 and 0.05 mg/kg with the relative standard deviations of 2.2~9.6%. Limit of detection and quantification were 0.005 and 0.02 mg/kg, respectively. An inter-laboratory study was conducted to validate the determination method in depth, and the results were satisfactory. All of the validation results revealed that the developed analytical method in this study is relevant for imicyafos determination in agricultural commodities and will be used as an official analytical method.