DOI QR코드

DOI QR Code

Thermal Design Analysis of Triple-Pressure Heat Recovery Steam Generator and Steam Turbine Systems

삼중압 열회수 증기발생기와 중기터빈 시스템의 열설계 해석

  • Published : 2002.03.01

Abstract

A computation routine, capable of performing thermal design analysis of the triple-pressure bottoming system (heat recovery steam generator and steam turbine) of combined cycle power plants, is developed. It is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. It can be applied to various parametric analyses including optimized design calculation. This paper presents analysis results for the effects on the design performance of heat exchanger arrangements at intermediate and high temperature parts as well as steam pressures. Also examined is the effect of steam sources for deaeration on design performance.

Keywords

References

  1. 김태국, 한규익, 서석호, 1995, '자연순환형수관식 폐열회수 보일러의 열전달-수순환 해석을 고려한 성능분석/크기결정 프로그램 개발 연구,' 대한 기계학회 추계학술대회 논문집 Vol. II, pp. 682-687
  2. 김상준, 노승탁, 1997, '다압 열회수 증기발생기의 설계점 및 탈설계점 해석,' 대한 기계학회 춘계학술대회 논문집 B, pp. 7-12
  3. 김영일, 김동섭, 김재환, 노승탁, 고상근, 1999, '열적 제한요소를 고려한 열회수 증기 발생기의 시동 특성 해석,' 대한기계학회 논문집 B, 제 23권, 제 11호, pp. 1410-1417
  4. 박형준, 김동섭, 노승탁, 2000, '열회수 증기발생기와 증기터빈 시스템의 동적 거동 해석,' 대한기계학회 논문집 B, 제 24 권, 제 7 호, pp. 994-1001
  5. Collier, J. H. and Thome, J. R., 1994, Convective Boiling and Condensation, 3rd ed., Oxford University press
  6. Chen, J. C., 1966, 'Correlation for Boiling Heat Transfer to Saturated Fluids in Convective Flow,' Ind. Eng. Chem. Proc. Des. Dev., 5
  7. ESCOA Corp., Fin Tube Manual, 1979, U.S.A
  8. 김동섭, 노승탁, 1996, '단축가스터빈의 설계점 및 부분부하 성능해석 프로그램 개발,' 대한기계학회 논문집(B), 제 20 권, 제 7 호, pp. 2409-2420
  9. PROPATH Group, 1997, PROPATH: A Program Package for Thermophysical Properties, Version 10.2, Kyushu University, Japan
  10. 김상준, 1997, 다압열회수 증기발생기의 설계점 및 탈설계점 해석, 서울대학교 공학석사 학위논문
  11. Spencer, R. C., Cotton, K. C., and Canon, C. N., 1963, 'A Method for Predicting the Performance of Steam Turbine-Generators ... 16,500 kW and Larger,' Journal of Engineering for Power, Vol. 85, pp. 249-301 https://doi.org/10.1115/1.3677341

Cited by

  1. Capture on the Performance of IGCC Plants vol.13, pp.1, 2010, https://doi.org/10.5293/KFMA.2010.13.1.009