• Title/Summary/Keyword: 뿜칠

Search Result 53, Processing Time 0.02 seconds

Development of Acceleration Duability test condition for Fireproof Spray-Application. (옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구)

  • Kim, Dae-Hoi;Lee, Gun-Chol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.170-171
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

Study on Changes of the Moisture Content of Sprayed Fire-Resistive Material according to Temperature Conditions (온도조건에 따른 내화뿜칠피복재의 함수율 변화 검토)

  • Lee, Gun-Cheol;Choi, Jung-Gu;Lee, Gun-Young;Kim, Dae-Hoi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.212-213
    • /
    • 2014
  • In case of fire spray protection sheath, fire resisting capacity is assessed for each material and installation method according to fire-resistive construction recognition. This study reviews effects of the percentage of water content that exist in fire spray protection sheath during the assess process of fire resisting capacity on fire resisting capacity, and changes of the percentage of water content according to temperature conditions. As a result of exams, as curing temperature is higher and thickness of specimen is thinner, decrease of the percentage of water content becomes significant.

  • PDF

Fire Resistance Performance of Box Type Linear Joint Fire Stop System for Curtain Wall (커튼월의 박스형 선형조인트 내화충전시스템의 내화성능)

  • Yeo, In-Hwan;Cho, Kyung-Suk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.357-360
    • /
    • 2011
  • 고층 건축물에 주로 사용되는 커튼월의 경우 구조체와의 접합으로 인해 층간 틈새가 발생하게 되고 이는 화재 시 틈새를 통해 화염이나 연기 등의 확산 경로가 될 수 있다. 본 연구에서는 커튼월 시스템에 적용되는 선형조인트 내화충전시스템의 개발을 위해 경제적이고 시공이 간편한 박스형 시스템을 도입하고 내부에 다양한 변경하여 내화성능을 평가하였으며, 그 결과 케이싱 내부의 단열재 20mm두께의 내화 뿜칠재와 석고보드를 케이싱 안쪽에 박스 형태로 구성한 시스템이 가장 안정적이고 온도상승도 작은 것으로 나타났다.

  • PDF

Development of Acceleration Duability test condition for Fireproof Spray-Application(II). (옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구(II))

  • Kim, Dae-Hoi;Lee, Gun-Chol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.109-110
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure (뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.

Development of Acceleration Duability Test Method for Fireproof Spray-Applocation (옥내용 뿜칠내화피복재의 촉진내구성 시험방법 연구)

  • Kim, Dae-Hoi;Lee, Gun-Chol;Lee, Sea-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.104-105
    • /
    • 2013
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. Fireproof spray-application also loses its performance and this performance loss of thr fireproof spray-application is very important because fire resistance of buildings depends on fireproof spray-application. So this study is to develop Acceleration durability test method of Fireproof spray-application, and use the Certification of fire resistant coating system.

  • PDF

An experimental study on bonding and bearing capacities of thin spray-on liner to evaluate its applicability as a tunnel support member (터널 지보재로서의 적용성 검토를 위한 박층 뿜칠 라이너의 부착성능과 지보성능의 평가)

  • Han, Jin-Tae;Lee, Gyu-Phil;Park, Young-Taek;Choi, Soon-Wook;Hwang, Gwi-Sung;Choi, Myung-Sik;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.6
    • /
    • pp.571-583
    • /
    • 2013
  • The use of Thin Spray-on Liner (TSL) as an alternative to shotcrete has drastically increased since 1990s when it was first developed and introduced to mines. In this study, tensile strength test, bond strength test, compression test with specimens coated by TSL, and two kinds of bending tests proposed by EFNARC (2008) were performed with two kinds of TSLs with different material compositions in order to evaluate their support capacities. As a result, both TSLs were shown to be satisfactory for the minimum performance requirements for a structural rock support suggested by EFNARC (2008) and tensile strength of a TSL was shown to increase as its content of polymer was higher. In contrast, its bond strength was shown to increase proportional to the content of a cementitious component especially at the early age.

An Analysis and Evaluation of Fire Resistance Performance for the Protected Steel Columns in Korea (국내 피복 철골기둥의 내화 성능 분석 및 평가)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 2009
  • Main structural steel members need fire-resistance measures to ensure their fire-resistance performance for a prescribed time. This paper analyzes and evaluates the fire-resistance performance of approved Korean fire-protection products for steel columns. These products are classified into products for board protection and for spray protection, samples of which were selected for the analysis. The fire-resistance performance was analyzed on the basis of Korean and European standards. The Korean standards are considered additional to the Euro-code standards for performance design. The Korean standards generally take more precautions to ensure safety on the temperature side, but require the reflection of material properties, the steel temperature calculation methodology, the profile factor, and the strength verification in a fire.

Characteristics of Temperature Distribution of Axially Loaded CFT Column with Fire Protection (축하중을 받는 내화피복 CFT기둥의 온도분포 특성)

  • Kim, Hae-Soo;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.78-85
    • /
    • 2010
  • When the fire occur, concrete filled steel tube(CFT) columns expected to form a much distinction in a fire resistance performance according to a kind of fire protection because the steel surface is directly exposed to high temperature. In this study, an experiment by three factors which were kind of fire protection, thickness of protection and time was performed to get the characteristics of temperature distribution types of CFT column with fire protection. As the result of this study, on a basis of heating temperature, spray protection was the most superior in a fire resistance performance, fireproof paint was next, and without fire protection was most inferior. In a heating time-location relationship, the temperature increased slowly on the surface of the concrete, but the temperature increased sharply on the surface of the steel.

A Study on Relations between Shape Factor and Temperature History of Steel of Composit Beam in Standard Fire under Same Thickness Condition of Spray-type Fire Resistant Materials (동일 내화뿜칠 피복조건에서 표준화재에 노출된 합성보의 강재 온도이력 및 단면형상계수와의 관계)

  • Yeo, In-Hwan;Cho, Kyung-Suk;Cho, Bum-Yean
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.72-77
    • /
    • 2012
  • When the concrete and steel combined composite beam is exposed to high temperature, concrete could delay temperature rising of steel by covering or increase heat capacity of structural member. For becoming of structural reinforcing by unification between materials, fire resistance rate of composite beam would be higher than simple steel beam. The temperature rising of exposed steel of composite beam is directly related with section shape and exposure length of steel. In this study, fire resistant tests were carried out for composite beams and steel beam with same thickness of spray-type fire resistant materials in standard fire, and after that, temperature histories were analysed and compared with shape factor. The correlation between steel temperature and shape factor was showed very high. This result suggests that if it can be predict the comparative advantage of member by factor which cause the performance enhancement, it could be conclude that an Standard Accreditation method can be adjust to members without indivisual certifiicate of accreditation.