Abstract
Main structural steel members need fire-resistance measures to ensure their fire-resistance performance for a prescribed time. This paper analyzes and evaluates the fire-resistance performance of approved Korean fire-protection products for steel columns. These products are classified into products for board protection and for spray protection, samples of which were selected for the analysis. The fire-resistance performance was analyzed on the basis of Korean and European standards. The Korean standards are considered additional to the Euro-code standards for performance design. The Korean standards generally take more precautions to ensure safety on the temperature side, but require the reflection of material properties, the steel temperature calculation methodology, the profile factor, and the strength verification in a fire.
주요 철골구조체는 일정한 시간동안 내화성능을 발휘하기 위한 내화조치를 필요로 한다. 본 연구는 철골기둥의 내화피복 국내인정 제품의 내화성능을 분석 평가함을 목적으로 한다. 대상제품은 보드피복과 뿜칠피복 두 종류의 제품을 대상으로 하여 샘플연구를 하였다. 국내기준과 유럽기준에 기초하여 제품의 내화성능을 분석하였다. 또한 국내기준을 유럽기준의 성능설계관점에서 분석 고찰하였다. 온도적 측면에서 국내기준의 내화성능은 일반적으로 안전하다고 사료되지만, 재료의 물성치 자료확충, 강재온도 산정방법, 프로필계수, 화재시 내력검증 등의 특성을 반영할 필요가 있다고 사료된다.