• Title/Summary/Keyword: 비부착형

Search Result 423, Processing Time 0.029 seconds

Numerical Study on Multiphase Flows Induced by Wall Adhesion (벽면부착에 의해 야기되는 다상유동에 관한 수치적 연구)

  • Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.721-730
    • /
    • 2012
  • The present paper presents a numerical study on multiphase flows induced by wall adhesion. The continuum surface force (CSF) model with the wall adhesion boundary condition model is used for calculating the surface tension force; this model is implemented in an in-house solution code (PowerCFD). The present method (code) employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with a volume capturing method (CICSAM) in a volume of fluid (VOF) scheme for phase interface capturing. The effects of wall adhesion are then numerically simulated by using the present method for a shallow pool of water located at the bottom of a cylindrical tank with no external forces such as gravity. Two different cases are computed, one in which the water wets the wall and one in which the water does not wet the wall. It is found that the present method efficiently simulates the surface tension-dominant multiphase flows induced by wall adhesion.

Experimental Study on the Machenical Properties of Composite Beam Composed End Reinforced Concrete and Center Steel (RC-S 복합보의 역학적 특성에 관한 실험적 연구)

  • Kim, Cheol Hwan;Chae, Won Tak
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.675-682
    • /
    • 2002
  • The beam of composite structure composed of the RC structure in the end part and steel structure in the central palt were investigated during cyclic loading, in order to evaluate strength, stiffness, and deformational capacity. The parameters used in this study include the amount of reinforced steel bar between the steel beam and RC structure and the existence of the sticking plate. Test results showed that all specimens had stabilized hysteresis loops. Likewise, the specimens with sticking plate had higher load-carrying capacity compared with the one without it. In addition, the stiffness of the composite structure was higher than the steel structure. All specimens also showed good rotational capacity.

Variance of Condenser Voltage, Current & Capacity by Voltage Unbalance (전압 불평형시 콘덴서 전압, 전류 및 용량의 변화)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.49-52
    • /
    • 2009
  • 3상 전압의 크기가 일정하고, 위상차도 $120^{\circ}$인 전압이 부하에 공급되는 것이 가장 바람직하지만, 부하의 운전조건과 설계에 따라 부하 단자에서의 3상에서는 균등한 전압이 되지 않는 경우가 많은 편이다. 이와 같은 전압 불평형이 존재할 경우 전류 불평형으로 이어져 기기의 출력저하나 부하에 졸지 않은 결과를 낳게 된다. 커패시터는 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터와 함께 사용되기도 한다. 커패시터에 리액터를 부착하여 사용하는 경우 사고 발생이 높은 편이다. 그래서 커패시터 설비에 전압 불평형이 존재할 경우 전압, 전류 그리고 용량의 변화가 어떻게 진행되는지 확인하는 것이 매우 중요하다. 본 연구에서는 전압 불평형율이 존재할 경우 커패시터 단독운전과 리액터의 부착시 전압, 전류 및 용량의 크기가 규정에서 제시한 범위이내 인지를 계산하였다.

  • PDF

SAR analysis with variety of the antenna structures on PCS handset (PCS 전화기의 안테나 구조에 따른 SAR 분석)

  • Kim, Hyoun-Kyoung;Park, Ju-Deok;Kim, Jin-Seok;Kim, Nam
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.11
    • /
    • pp.8-16
    • /
    • 2000
  • In this paper, on calculating SARs on human head using computer simulation, SARs caused by PCS handsets are calculated and compared, and the design parameters that affect SAR values are analyzed. Is and 10 g peak averaged SARs are calculated as the type of antenna, the location of antenna, and the type of handset are changed and SAR distributions as depth of human head are shown. Among the antennas on flip type handsets, side mounted PIFA has the lowest SARs 1g and 10g peak averaged SARs are 0.686W/kg and 0.353W/kg. The SARs caused by monopole antenna on folder type handset are 1.133W/kg and 0.709W/kg. and are about 30% lower than monopole 1.759W/kg and 0.978W/kg, respectively. SAR distributions as depth of human head of side mounted PIFA and monopole antenna on folder-type handset are more slowly changed than those of top mounted PIFA and monopole antenna on flip-type handset.

  • PDF

Parameter Analysis for Design of Pretension Girder Bridge for Urban Maglev Transit (도시형 자기부상열차 프리텐션 거더교의 설계변수 분석)

  • Lee, Jae-Ho;Kim, Do-Hak;Kim, Seung-Hyun;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2016
  • Parameter analysis of a pretension girder bridge for urban maglev transit was performed to identify the main design parameters and their effect. Girder deflection at mid-span is the most important design criteria of urban maglev transit. Therefore, concrete compressive strength, girder height, girder length, and unbonded tendon length were selected as the design parameters that relate to girder deflection. In addition, tendon layout and unbonded tendon ratios were also considered as design parameters to control the top stress of the pretension girder section at the support. The analysis results show that both the girder height and length are dominant design parameters governing girder deflection, more important than compressive strength and unbounded tendon length. And, sensitivity analysis makes this study suggest design weight value. In terms of stress, a tendon layout that can satisfy the unbounded tendon rule requires an additional tendon or rebar at the upper section to control the tensile stress on top of the section. Therefore, to improve feasibility and constructability in the future, an enhanced unbonded tendon rule considering the load characteristics of the urban maglev system should be studied.

THE EFFECTS OF FLUORIDE RELEASING ORTHODONTIC SEALANT ON THE SHEAR BOND STRENGTH Of LIGHT-AND CHEMICAL-CURED ORTHODONTIC RESINS (불소가 유리되는 교정용 전색제가 광중합형 및 화학중합형 교정용 접착제의 전단결합강도에 미치는 영향)

  • Kim, Bong-Hyun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.781-789
    • /
    • 1997
  • The purpose of this study was to evaluate the effects of fluoride relasing orthodontic sealant on the shear bond strength of light-and chemical-cured orthodontic rosins, to compare the shear bond strenth with light-and chemical-cured orthodontic resins, and to identify the changes of shear bond strength by rebonding in vitro. The brackets were divided into eight groups. Each group of metal brackets had different bonding mechanisms with adhesives. Group A : Transbond only Group B : Mono-Lok 2 only Group C : Light cured FluoroBond+Transbond Group D : Light cured FluoroBond+Mono-Lok 2 Group E : Transbond only(rebonded) Group F : Nomo-Lok 2 only(rebonded) Group G : Light cured FluoroBond+Transbond(rebonded) Group H : Light cured FluoroBond+Mono-Lok 2(rebonded) 65 extracted human premolars were prepared for bonding and 65 metal brackets for each group were bonded to prepared enamel surfaces of buccal surfaces as the above prescription. 24 hours bonding after, the Instron universal testing machine was used to test the shear bond strength of metal brackets to enamel. After debonding, same kind of metal brackets for each group were rebonded to prepared enamel surfaces of buccal surfaces to test the shear bond strength at the rebonding to enamel. Statistical analysis of the data was carried out Student's t-test ANOVA test, and Scheffe test using $SPSS/PC^+$ The results were as follows : 1. The order of shear bond strength was Group B(11.84MPa), Group A(10.75MPa), Group, D(9.69MPa), and Group C(9.39MPa)in lst bonded groups. 2. The order of shear bond strength was Group E(7.40MPa), Group G(6.48MPa), Group F(5.89MPa), and Group H(5.15MPa) in rebonded groups. 3. The shear bond strength of chemical cured orthodontic rosins had higher than that of light-cured orthodontic resins in all groups, but there was no statistical significance between groups(P>0.05). 4. In rebonded groups, the shear bond strength of light cured orthodontic rosins had higher than that of chemical cured orthodontic resins, but there was no statistical significance between groups(P>0.05). 5. The shear bond strength of all rebonded groups progressively decreased than that of 1st bonded groups, and there was statistical significance between groups(p<0.05, p<0.001).

  • PDF

FEM Analysis of Distributed Optical Fiber Sensors for the Strain Transfer (표면부착된 분포형 광섬유 센서의 유한요소해석)

  • Kim, Sang-Hoon;Lee, Jung-Ju;Kwon, Il-Bum;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.16-23
    • /
    • 2001
  • Comparing with general optical fiber sensors performing localized measurement, distributed optical fiber sensors can measure along an optical fiber, and they have large measuring range. The surface-mounting method with epoxy adhesive is general in attaching optical fiber sensors to structures, This is also appliable to the structural integrity monitoring with Brillouin-scattering distributed optical fiber sensors. In this paper, Brillouin-scattering distributed optical fiber sensors, which are attached to the surface of a structure with epoxy adhesive, was verified with the finite element method. From the analysis results of strain transfer through the structure, optical fiber coating, cladding and core, the strain transfer rates were calculated. And the influence of the epoxy free-end was also studied.

  • PDF

Analysis of the Load Carrying Behavior of Shear Connection at the Interface of Encased Composite Beams (매입형 합성보의 전단합성거동에 대한 비교분석)

  • Shin, Hyun Seop;Heo, Byung Wook;Bae, Kyu Woong;Kim, Keung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.67-79
    • /
    • 2008
  • In this study, a bending test with three encased composite beams were carried out and analyzed using FEM in order to find how chemical adhesion, interface interlock, friction and composite action by shear studs contribute to stiffness, strength and composite action in the interface of encased compo site beams. The test and results of the FEM analysis showed that the difference in the ultimate moment capacity of the composite beams with and without studs is under 10%. The reason is that the effect of chemical adhesion, interface interlock, and friction in the interface on the composite action is so high that the encased beams have a moment capacity above some defined magnitude. Also, the increment of moment capacity up to plastic moment is not large and the increase of linearly proportioned.

Analysis of Influence Factors for PSC Beams with Unbonded External Tendons (외부 비부착 강선에 의해 보강된 PSC보의 영향인자 분석)

  • Kwak, Hyo-Gyoung;Son, Je-Kuk;Kim, Sun-Yong;Park, Young-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.261-271
    • /
    • 2006
  • Many uncertainties affecting to the structural behavior of prestressed concrete (PSC) bridges reinforced with the un bonded external tendons are analyzed on the basis of the analytical method introduced in the companion paper. Many design parameters, which must be considered in design procedure, such as friction slip at the deviators, number of deviators, time-dependent deformations of concrete, relaxation of tendon and influence of loading history in PSC bridges are reviewed, and a lot of valuable results are obtained through this parametric study. In advance, the structural responses according to the external tendon profiles are analyzed to grasp if an optimum tendon profile depends on the applied loading type, and the obtained results show that the most stable structural response is revealed when the locations of deviators are coincident with the loading points.

Measurement of Hardness and Adhesiveness of Cooked-Rice (밥블록을 이용한 찰밥의 경도 및 부착성 측정법)

  • Lee, Y.J.;Hwang, S.W.;Park, Y.S.;Yoon, W.J.;Chun, J.K
    • Applied Biological Chemistry
    • /
    • v.38 no.5
    • /
    • pp.398-402
    • /
    • 1995
  • Hardness and adhessiveness of cooked rice were measured with rice grain and rice block methods by texturemeter. In grain method 3, 4 and 5 grains were arranged and subjected to the texture test with a plastic plunger at 95% strain and 0.5mm/sec speed. The hardness were 7.4kg, 7.5kg and 10.0kg respectively and the coefficient of variation ranged from 37.0% to 25.9%, which was mainly due to the irregular geometry of the grains in each specimen set Adhesiveness could not be measured with this method. A cylindrical rice block($H/D=20mm{\times}15mm$) was made for the texture analysis. The hardness was 2.1 kg with coefficient of variation ranging from 2.8 to 7.0%, and the block method was s more reproducible compared to the grain method. A grooved plastic plunger and platform were designed for the measurement of adhesiveness of cooked rice block. The adhesiveness was 0.68kg sec and the coefficient of the variation was 4.6%.

  • PDF