• Title/Summary/Keyword: 복합저항성

Search Result 634, Processing Time 0.033 seconds

Effect of Nutrition and Exercise Modification Therapy on Metabolism Efficiency of Middle-aged Women Through Convergence (융복합을 활용한 영양과 운동중재요법이 중년여성의 대사 효율성에 미치는 영향)

  • Chea, Su-In;Nam, Sang-Nam;Kim, In-Dong
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.393-400
    • /
    • 2015
  • The purpose of this study to examine the effect of intermittent fasting and resistance exercise on sex hormone and glucose metabolism of middle-aged women for 12 weeks. The two groups classified that one group(EG) was done intermittent fasting and resistance exercise both, the other group(CG) was controled. The group of EG was applied doing intermittent fasting 1 time for 24 hours a week, and doing resistance exercise 3 times for 60 minutes a week. The intensity of the exercise was 60%. Each measurement variable measured before and after 12 weeks to investigate the effect. During this study got the result with this step. First, EG have shown small interaction with sex hormone. Second, EG have shown small interaction with resistance exercise. Therefore, this study give us positive result to effect of intermittent fasting and resistance exercise on sex hormone and glucose of middle-aged women for 12 weeks. However, it has limitation to verify effect of intermittent fasting and resistance exercise.

Affecting Analysis of Air Content on the Freeze-Thaw Durability of Concrete (콘크리트의 동결융해 내구성에 공기량이 미치는 영향 분석)

  • Lee, Beung-Duk;Kim, Hyun-Joong;Kang, Hye-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.565-568
    • /
    • 2008
  • Domestic area of most be happened chloride deicer damage. Because daily mean temperature is below 0$^{\circ}C$ from the area of domestic most. Concrete durability influence Air Content. Presently, We used to AE(air-entraining agent) for increase freeze-thaw durability. So, on concrete Air Spacing ratio used $200{\mu}m{\sim}230{\mu}m$ in Canada and under $250{\mu}m$ in Japan institution. Use of Air content has been and will continue to be a major part of concrete durability and scaling. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. The prepared optimum mix concrete in this study show that freeze-thaw and scaling resistance of Non-AE(air content 1.5%) and AE (air content 4.5%, 7.2%). Solution concentrations of deicing agent were good result, and the pore system and change of hydration products is not difference comparing before freeze-thaw test.

  • PDF

Characteristics of Silane Treated Graphene Filled Nanocomposites Exposed to Low Earth Orbit Space Environment (저궤도 우주환경하의 실란처리된 그래핀 첨가 나노 복합재료의 물성특성)

  • Noh, Jae-Young;Jin, Seung-Bo;Kim, Chun-Gon
    • Composites Research
    • /
    • v.28 no.3
    • /
    • pp.130-135
    • /
    • 2015
  • This study investigates the property of graphene filled polymer nanocomposites in LEO(Low Earth orbit) environment conditions. In order to improve compatibility with polymer matrices and resistance of carbon material against AO(Atomic oxygen) attack, silanization of graphene oxide with organosilane was carried out. The corresponding moieties were characterized through X-ray photoelectron spectroscopy (XPS). Graphene oxide filled nanocomposites were prepared using solution based processing methods. The sets of specimen series were tested in an accelerated LEO simulated space environment facility. Graphene oxide and silane treated graphene oxide reinforced nanocomposites were compared with neat epoxy. The comparison revealed that the silane treated graphene filled polymer composite shows inherent resistance against atomic oxygen attack while the lack of silane treatment resulted in a reduction in performance.

Facture Prediction in SiC Fiber Reinforced $Si_3N_4$ Matrix Composites from Electrical Resistivity Measurements (전기저항측정에 의한 SiC섬유강화 $Si_3N_4$기 복합재료의 파괴예측)

  • Sin, Sun-Gi
    • Korean Journal of Materials Research
    • /
    • v.10 no.5
    • /
    • pp.364-368
    • /
    • 2000
  • SiC fiber reinforced $Si_3N_4$ matrix composites combined with electrical conductive phases of carbon fiber and WC powder fabricated by hot pressing at 1773K. The ability to predict fracture in the ceramic matrix composites was evaluated by measuring simultaneous load-deflection and electrical resistanc difference-deflection curves in four point bending tests. The changes in electrical resistance differences closely corresponded to the fracture behavior of the composites. Different electrical conductive phases are suited to predicting different stages and rates of fracture. These obsevations how that it is possible to perform "in situ" fracture detection in ceramic composites.

  • PDF

A Study on Analysis Technique for Chloride Penetration in Cracked Concrete under Combined Deterioration (복합열화에 노출된 균열부 콘크리트 내의 염화물 침투 해석 기법에 대한 연구)

  • Kwon, Seung-Jun;Song, Ha-Won;Byun, Keun-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.359-366
    • /
    • 2007
  • Recently, analysis researches on durability are focused on chloride attack and carbonation due to increased social and engineering significance. Generally, chloride penetration and carbonation occur simultaneously except for in submerged condition and chloride behavior in carbonated concrete is evaluated to be different from that in normal concrete. Furthermore, if unavoidable crack occurs in concrete, it influences not only single attack but also coupled deterioration more severely. This is a study on analysis technique with system dynamics for chloride penetration in concrete structures exposed to coupled chloride attack and carbonation through chloride diffusion, permeation, and carbonation reaction. For the purpose, a modeling for chloride behavior considering diffusion and permeation is performed through previous models for early-aged concrete such as MCHHM (multi component hydration heat model) and MPSFM (micro pore structure formation). Then model for combined deterioration is developed considering changed characteristics such as pore distribution, saturation and dissociation of bound chloride content under carbonation. The developed model is verified through comparison with previous experimental data. Additionally, simulation for combined deterioration in cracked concrete is carried out through utilizing previously developed models for chloride penetration and carbonation in cracked concrete. From the simulated results, CCTZ (chloride-carbonation transition zone) for evaluating combined deterioration is proposed. It is numerically verified that concrete with slag has better resistance to combined deterioration than concrete with OPC in sound and cracked concrete.

Analyses of Structural Performances for RC High-Rise Residential Complex Building under Construction (철근콘크리트 초고층 주상복합 건물의 시공 중 구조성능 분석)

  • Hwang, Young-Jin;Kim, Jae-Yo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.19-27
    • /
    • 2015
  • Recently, the most of domestic high-rise residential complex buildings are constructed with reinforced concrete structures, which may bring structural problems during construction. This study is aimed to analyze structural safety and lateral load-resisting performance of RC high-rise residential complex building under construction. The tower-typed building with 60 floors is selected as a sample model, and numerical analyses are performed. The structural performances of building structures at construction stages, which are resulted form the analyses of numerical models completed up to 10th, 20th, 30th, 40th, 50th, or 60th floor, are compared to those of the completed building structure. For the comparisons of structural performances, modal shapes and fundamental periods of building structures, lateral load-resisting performances, and structural design performances of structural members are considered. The lateral displacement and story drift ratio are analyzed for lateral load-resisting performances, and comparisons of design ratios at construction and design stages are performed for structural design performances of structural members. The guideline of design loads and structural analysis schemes for checking the safety of RC high-rise building under construction is presented.

Geostatistical Integrated Analysis of MASW and CPTu data for Assessment of Soft Ground (연약지반 평가를 위한 MASW탐사와 CPTu 자료의 지구통계학적 복합 분석)

  • Ji, Yoonsoo;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.4
    • /
    • pp.187-199
    • /
    • 2016
  • In order to delineate the soft ground distribution, an integrated geostatistical analysis was performed using the MASW (Multichannel Analysis of Surface Wave) which has the information of overall region and CPTu (Piezo Cone Penetration Test) which provides the direct information of the measuring point of the ground. MASW results were known to have close relationship with the ground stiffness. This correlation was confirmed through the comparison of MASW data obtained from two survey lines to the laboratory test with extracted soil samples. 3D physical property distribution in the study area was acquired by geostatistical integrated analysis with the data of tip resistance ($q_c$) and pore pressure (u) from the CPTu obtained at 6 points within the study area. The integrated analysis was conducted by applying the COSGSIM (Sequential Gaussian Co-Simulation) technology which can carry out the simulation in accordance with the spatial correlation between the MASW results and both tip resistance and pore pressure. Besides the locations of CPTu, borehole investigations were also conducted at two different positions. As a result, the N value of SPT and borehole log could be secured, so these data were used for the analysis of the geotechnical engineering accuracy of the integrated analysis result. For the verification of reliability of the 3D distribution of tip resistance and pore pressure secured through integrated analysis, the geotechnical information gained from the two drilling areas was compared, and the result showed extremely high correlation.

Self-Sensing of Single Carbon Fiber/Carbon Nanotube-Epoxy Composites Using Electro-Micromechanical Techniques and Acoustic Emission (전기적-미세역학시험법과 음향방출을 이용한 단일 탄소섬유/탄소나노튜브-에폭시 나노복합재료의 자체-감지능)

  • Park, Joung-Man;Jang, Jung-Hoon;Wang, Zuo-Jia;Kwon, Dong-Jun;Park, Jong-Kyu;Lee, Woo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.411-422
    • /
    • 2010
  • Self-sensing on micro-failure, dispersion degree and relating properties, of carbon nanotube(CNT)/epoxy composites, were investigated using wettability, electro-micromechanical technique with acoustic emission(AE). Specimens were prepared from neat epoxy as well as composites with untreated and acid-treated CNT. Degree of dispersion was evaluated comparatively by measuring volumetric electrical resistivity and its standard deviation. Apparent modulus containing the stress transfer was higher for acid-treated CNT composite than for the untreated case. Applied cyclic loading responded well for a single carbon fiber/CNT-epoxy composite by the change in contact resistivity. The interfacial shear strength between a single carbon fiber and CNT-epoxy, determined in a fiber pullout test, was lower than that between a single carbon fiber and neat epoxy. Regarding on micro-damage sensing using electrical resistivity measurement with AE, the stepwise increment in electrical resistivity was observed for a single carbon fiber/CNT -epoxy composite. On the other hand, electrical resistivity increased infinitely right after the first carbon fiber breaks for a single carbon fiber/neat epoxy composite. The occurrence of AE events of added CNT composites was much higher than the neat epoxy case, due to micro failure at the interfaces by added CNTs.

Effective Estimation of Porosity and Fluid Saturation using Joint Inversion Result of Seismic and Electromagnetic Data (탄성파탐사와 전자탐사 자료의 복합역산 결과를 이용한 효과적인 공극률 및 유체포화율의 추정)

  • Jeong, Soocheol;Seol, Soon Jee;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.2
    • /
    • pp.54-63
    • /
    • 2015
  • Petrophysical parameters such as porosity and fluid saturation which provide useful information for reservoir characterization could be estimated by rock physics model (RPM) using seismic velocity and resistivity. Therefore, accurate P-wave velocity and resistivity information have to be obtained for successful estimation of the petrophysical parameters. Compared with the individual inversion of electromagnetic (EM) or seismic data, the joint inversion using both EM and seismic data together can reduce the uncertainty and gives the opportunity to use the advantages of each data. Thus, more reliable petrophysical properties could be estimated through the joint inversion. In this paper, for the successful estimation of petrophysical parameters, we proposed an effective method which applies a grid-search method to find the porosity and fluid saturation. The relations of porosity and fluid saturation with P-wave velocity and resistivity were expressed by using RPM and the improved resistivity distribution used to this study was obtained by joint inversion of seismic and EM data. When the proposed method was applied to the synthetic data which were simulated for subsea reservoir exploration, reliable petrophysical parameters were obtained. The results indicate that the proposed method can be applied for detecting a reservoir and calculating the accurate oil and gas reserves.

Development of Subsection Division Method to Estimate a Composite Roughness Coefficient (복합 조도계수 산정을 위한 단면 분할기법 개발)

  • Kim, Ji-Sung;Kim, Keuk-Soo;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.11
    • /
    • pp.945-956
    • /
    • 2010
  • Practically, the composite roughness coefficient, which is the equivalent roughness coefficient of a cross-section where the wall roughness is not constant along the wetted perimeter, is used to describe the flow conditions in open channels. In this study, it was conducted that the previous formulae was classified according to a weighting factor of the local resistance. The new subsection division method was also developed based on the force-balance concept in each subsection. The accuracy of the proposed method was examined and the applicability and limitation of the 13 existing formulae were analyzed by comparing the calculated with the experimental measured data from Djajadi (2009) and Knight and Macdonald (1979). It was found that Horton's method might underestimate the total conveyance of a composite channel and Lotter's method showed a good agreement between calculated and measured data. However, the proper division method, such as the proposed method based on the Z-method, is required for the application of Lotter's method.