• Title/Summary/Keyword: 복합시트

Search Result 142, Processing Time 0.021 seconds

Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets (점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구)

  • Kim, Soo-Yeon;Park, Jong-Sun;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.377-386
    • /
    • 2021
  • In April 2019, this study was enacted as a test method for the performance of waterproof layers in an environment where complex deterioration and structural behavior are simultaneously applied, but some existing standards were implemented to point out the errors of the method that should be supplemented. Thus, in establishing standards for (tentative) adhesive waterproofing sheets, field workability and quantification of test results were studied on the structural behavior response performance test methods included as test items. In addition, the performance evaluation of adhesive-type composite waterproof sheets was conducted based on the considered contents to review improvements such as applicability as an item of standard standards and field workability related problems.

Evaluation of Structural Performance of Reinforced Concrete Beams using Hybrid Retrofitting with Groove and Embedding FRP Rod and CFRP Sheet (표면요철 매입형 FRP봉과 CFRP시트를 복합 보강한 철근콘크리트 보의 구조성능 평가)

  • Ha, Gee-Joo;Ha, Young-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.41-49
    • /
    • 2014
  • In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam using hybrid retrofitting with two materials (groove and embedding FRP rod, CFRP sheet) in existing reinforced concrete buildings. Seven reinforced concrete beams, retrofitted groove and embedding FRP rod (NER series) and groove and embedding FRP rod with CFRP sheet (NERL series), and standard specimen (NBS) were constructed and tested under monotonic loading. Design parameters of test specimens are the amount of groove and embedding FRP rod and lapping CFRP sheet. Test results showed that the maximum load carrying capacity of specimens with groove and embedding FRP rod and groove and embedding FRP rod with CFRP sheet (NERL series) were increased the by 12~46% and 22~77% respectively in comparison with the standard specimen NBS. Test specimens NER series were failed with the adhesion slip and concrete cover separation. And test specimens NERL series were failed with the adhesion slip due to the confining effect of lapping CFRP sheet.

Effects of Annealing on Electromagnetic Wave Absorption Characteristics in FeSiCr Flakes/Polymer Composite Sheets (FeSiCr 박편/폴리머 복합 시트의 전자파 흡수 특성에 미치는 합금 어닐링 효과)

  • Kim, Ju-Beom;Noh, Tae-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.83-88
    • /
    • 2013
  • The soft magnetic Fe-Si-Cr flakes with the thickness of about 1 ${\mu}m$ were annealed at 500 and $700^{\circ}C$ for 1 h, and the composite sheets for electromagnetic wave noise absorber available for quasi-microwave band were fabricated by using these annealed flakes and polymer. Further the power loss characteristics of the composite sheets was investigated to clarify the annealing effect on electromagnetic wave absorption properties. The power loss decreased in the frequency range of several GHz when the annealed flakes were used as compared to the sheet using the as-milled FeSiCr alloy flakes. Moreover the sheets using annealed flakes exhibited lower value of real and imaginary part of complex permeability. These inferior electromagnetic wave absorption properties of the composite sheets using annealed alloy flakes were considered to be obtained by the enhanced eddy current effect upon annealing-induced recovery of microstructure and resulted low complex permeability.

Thermal Insulation Performance of Composite Waterproofing Method of Thermal Supplement Type (단열 보완형 복합방수공법의 단열성능에 관한 연구)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 2014
  • Insulation of rooftop is one of the major performance to energy-saving construction. Further, waterproofing performance is also important. For such a reason, it is need to develop waterproofing method containing thermal insulation property. This study was wanted to evaluate thermal insulation performance about the composite waterproofing method of thermal supplement type that is developed recently. As a result of waterproofing performance test, every test item was showed over the performance standards of KS (Korean (Industrial) Standards). And the result of thermal insulation performance test, the highest temperature in the styrofoam box was $25.91^{\circ}C$, the bubble sheet box was $17.28^{\circ}C$, the insulation sheet box was $15.47^{\circ}C$ and the waterproofing sheet box of thermal supplement type was $24.11^{\circ}C$. In observations of thermal bridges of sheet's joint, thermal bridges was not identified at the sheet's joint. As a result, composite waterproofing method of thermal supplement type is interpreted to have thermal insulation performance.

A study on the toilet lifting seat for the elderly (노약자를 위한 변기 리프팅 시트 연구)

  • Minseo Kim;Hyemin Son;Jinho Cho;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.459-464
    • /
    • 2024
  • The purpose of this study is to design a toilet lifting seat to prevent falls accidents in the elderly while using the toilet. Prior to design, laws and national standards related to restroom use were investigated and the available space for the assistive devices to be installed was determined. In additions, considering the body size and operating range of the elderly, the optimal final position of the toilet seat is set so that users can use it more safely and conveniently without external help. Moreover, in order to provide an effective standing assistance function, a complex 4-bar link structure was applied to enable simultaneous seat elevation and angle adjustment when operating the device, and the appropriate link shape and dimensions were determined using a linkage program and UG NX. FEA analysis using ANSYS Workbench is performed to ensure the robustness of the stretched linkage and the feasibility of the lifting seat is verified through fabrication.

Fabrication and Characterization of the Carbon Fiber Composite Sheets (탄소섬유를 이용한 열가소성 복합재료 시트 제조 및 특성)

  • Lee, Yun-Seon;Song, Seung-A;Kim, Wan Jin;Kim, Seong-Su;Jung, Yong-Sik
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.168-175
    • /
    • 2015
  • Recently, the applications of carbon fiber reinforced plastics (CFRPs) have become broader than ever when it comes to such industries as automotive, ships, aerospace and military because of their lightweight-ness and high mechanical properties. Thermosetting plastics like epoxy are frequently used as the binding matrix in CFRPs due to their high hardness, wetting characteristics and low viscosity. However, they cannot melted and remolded. For this reason, thermosetting plastic wastes have caused serious environmental problems with the production of fiber reinforced plastics. Thus, many studies have focused on the carbon fiber reinforced thermoplastics (CFRTPs) and recycling carbon fiber. In this study, recycled carbon fiber (RCF) was prepared from CFRPs using a pyrolysis method, which was employed to separate resin and carbon fiber. The degree of decomposition for epoxy resin was confirmed from thermal gravimetric analysis (TGA) and scanning electron microscope (SEM). The RCF was cut and ground to prepare a carbon fiber composite sheet (CFCS). CFCS was manufactured by applying recycled carbon fibers and various thermoplastic fibers. Various characterizations were performed, including morphological analyses of surface and cross-section, mechanical properties, and crystallization enthalpy of CFCS at different cooling conditions.

A Study on Microscopic Damage Behavior of Carbon Fiber Sheet Reinforced Concrete using Acoustic Emission Technique (음향방출 기법을 이용한 탄소섬유시트강화 콘크리트의 미시적 손상 거동에 관한 연구)

  • 이진경;이준현;정성륜
    • Composites Research
    • /
    • v.12 no.4
    • /
    • pp.62-70
    • /
    • 1999
  • It was well recognized that damages associated mainly with the aging of civil infrastructrues were one of very serious problems for assurance of safety and reliability. In recent, carbon fiber sheet(CFS) has been widely used for reinforcement and rehabitation of damaged concrete beam. However, the fundamental mechanism of load transfer and its load-resistant for carbon fiber sheet reinforced concrete are not fully understood. In this study, three point bend test has been carried out to understand the damage progress and micro-failure mechanism of CFS reinforced concretes. For these purposes, four kinds of specimens are used, that is, concrete, respectively. Acoustic Emission(AE) technique was used to evaluate the characteristics of damage progress and failure mechanism of specimens. In addititon, two-dimensional AE source location was also performed to monitor crack initiation and propagation processes for four types of these specimens.

  • PDF

EMI Noise Suppression Effectiveness of Magnetic Composite Sheet Suitable for EL Touch Pannel

  • Byun, In-Ho;Woo, Seo-Hwi;Lee, Seong-Eui;Lee, Kyung-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.187-187
    • /
    • 2010
  • 현대의 전기전자 기술의 발전속도가 급격히 빨라짐에 따라서 디지털 전자기기는 많은 데이터와 빠른 전송속도가 요구되어지고 있으며 이로 인해 예상치 못한 고주파 노이즈 신호의 문제가 심각해지고 있다. 최근 디지털 전자기기 중 디스플레이 표시장치에서 구동전압 인가 시 발생하는 근역장 방사노이즈가 문제가 되고 있고, 정전용량방식 (Capacitive Overlay)Touch Pannel에서 터치 시 오작동을 일으키는 EL 면광원의 EMI(Electro-Magnetic Interference, 전자방해)가 본 연구에서 해결하고자 하는 문제이다. EL 면광원의 구동전압이 증가함에 따라서 Touch Panel에 인가되는 근역장 방사노이즈의 세기를 측정하였고 근역장 방사노이즈를 감쇄할 수 있는 Flexible한 자성복합시트에 대해서 연구하였다. EL Display Pannel에 Flexible한 자성 복합시트를 채용하여 Flexible Display 장비의 근역장 방사노이즈 감쇄에 효과가 있음을 확인하였다.

  • PDF