In evaporating distillation plant velocity characteristic of fluid to flow in a evaporator have great influence on flash phenomenon. In This experimental study about impinging water jet region having the inflow of wall jet flow and effect of baffle height to flow velocity in after baffle region, making a application by PIV.
The objective of the present study was to two-dimensionally investigate the characteristics of flow and wall shear stress under pulsatile flow in the aneurysm which is a local dilatation of the blood vessel for pulsatile flow. The numerical simulation using the commercial software were carried out for the diameter ratios(ratio of maximum diameter of aneurysm to the diameter of blood vessel) ranging from 1.5 to 2.5 and Womersley number, 15.47. It was shown that a recirculating flow at the bulge was developed and disappeared for one Period and the strength of vortex increased with the diameter ratio Especially. at time of 3.19s. the very weak recirculating flow was developed at the left upper sites of the aneurysm. The maximum values of the wall shear stress increased in Proportion to the diameter ratio. However. the Position of a maximum wall shear stress was the distal end of the aneurysm(z = 35mm) regardless of the diameter ratios.
유체역학적 추력 방향 제어(Fluidic Thrust Vector Control) 방법 중 하나인 동축류 제어 유동 분사를 이용한 추력 방향 제어(Co-flow Thrust Vector Control)의 작동 특성에 대해서 연구하였다. 이 제어 방법은 점성 유동이 벽면에 부착되어 흐르는 코안다 효과(Coanda Effect)를 이용하여 주 유동을 편향 시키는 방법으로서 그 편향각은 이러한 제어 유동 노즐 출구의 플랩 형상에 영향을 받는 것으로 알려져 있다. 이 연구에서는 출구 플랩 형상을 여러 가지로 바꾸어 가며 주 유동의 전압력 300kPa일 때 제어 유동의 편향각이 포화되는 제어유동의 전압력을 측정하였다. 그 결과 쐐기형 플랩의 각도가 증가할수록 포화 영역에서의 편향각은 증가하며 그 각은 플랩의 각도와 일치한다. 그러나 각도가 증가할수록 제어 유동이 플랩의 벽면을 지나면서 팽창파에 의해 가속되어 충격파을 발생시키게 되고 이 충격파는 주 유동에게까지 전파되어 주 유동 제트의 속도를 감소시킨다.
Park, Jong-Pyo;Lee, Sang-Ho;Lee, Jung-Min;Park, Jae-Hyeon
Proceedings of the Korea Water Resources Association Conference
/
2006.05a
/
pp.1017-1021
/
2006
인공순환수로에 정육면체 수리구조물을 구간별로 설치하여 흐름특성에 따른 깔따구의 서식경향을 조사하였다. 정밀한 흐름특성을 분석하기 위하여 난류계산을 수행하였으며, 인공순환수로에 깔따구를 투입하고 3일경과 후 깔따구의 개체수를 조사하였다. 인공순환수로는 단면 폭 29cm, 높이 30cm인 구조로 제작되었으며 직선구간의 길이는 120cm이다. 인공순환수로의 직선구간에 길이 10cm의 정육면체 수리구조물을 20cm 간격으로 양쪽 벽면부에 4개씩 균일하게 설치하였다. 자연하천에서 채집된 원수를 수심 20cm가 되도록 투입한 후 유기물을 하상에 고르게 깔고, 회전날개를 이용하여 평균유속 10cm/s로 안정화 시킨 후 깔따구 투입하였다. 실험시작 3일 경과 후, 깔따구의 서식경향을 조사한 결과 깔따구는 수리구조물 직하류부에 주로 서식하였다. 이는 주 흐름방향 유속분포가 수리구조물 후방에서 급격히 작아져 깔따구들이 정착하기 좋은 환경을 제공하기 때문인 것으로 판단된다. 또한 인공순환수로 직선구간의 안쪽 벽면과 바깥쪽 벽면의 깔따구 개체수는 안쪽 벽면이 바깥쪽 벽면에 비하여 2배 정도 많다. 이는 수리구조물 사이 안쪽 벽면 하상의 시계방향 회전흐름 때문으로 분석되며 상대적으로 이러한 흐름은 바깥쪽 벽면에서 작다. 실험 및 수치해석 결과, 깔따구는 상대적으로 유속이 작은 곳에 서식하며, 이차류의 경향에 따라 서식처를 이동하는 것으로 분석되었다. 향후 생태적 기능을 고려하여 다양한 수리학적 조건 하에서 난류계산 및 유속측정을 통한 연구가 필요하다. 이와 같은 연구는 친환경적으로 하천을 복원시키는데 유용한 자료를 제공할 수 있을 것으로 생각된다.은 silt나 clay보다 입경이 큰 모래나 자갈을 경유 하면서 오염물의 저감효과가 감소한 것으로 판단된다. 그러나 유입유량의 대부분이 표면으로 유출된다는 점을 고려할 때 표면유출수의 오염도를 낮추는 것이 유입오염물 저감효과에 보다 큰 효과가 있을 것으로 판단된다.문에 자료의 이상적 유지 관리가 이루어지며 복잡한 2차원 수질해석 모형을 수월하게 운영할 수 있는 시스템으로 개발하였다.제외하면, 부자측정 방법에 의한 유량산정시 가장 큰 오차원인은 홍수시 측정된 유속측선의 위치와 홍수 전후로 측정된 횡단면상의 위치가 일치하지 않는 점과, 대부분 두 측정 구간의 평균값을 대푯값으로 사용한다는 점이다. 본 연구는 다년간의 유량 측정 및 검증 경험과 자료를 토대로 현장에서 부자를 이용하여 측정된 측정성과를 정확도 높은 유량자료로 산정하는데 있어서의 문제점을 도출하고, 이로 인해 발생하는 오차를 추정하여 그 개선방안을 제시해 보고자한다. 더불어 보다 정확한 유량 산정을 위한 기준과 범주를 제시하고자 한다.리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게
Transactions of the Korean Society of Mechanical Engineers B
/
v.37
no.10
/
pp.927-932
/
2013
The intracranial aneurysm model is extracted based on the Computed Tomography (CT) scan images. Computational fluid dynamics simulations were conducted under both steady and realistic flow conditions in ANSYS-FLUENT. The minimum wall shear stress in the intracranial aneurysm tended to occur in the aneurysmal region. The magnitude of wall shear stress along inner wall of the curvature in the right M1 segment of middle cerebral artery is approximately 20 times higher than that along both the proximal and distal walls. However, the magnitudes of the wall shear stress at the aneurysm region were considerably low. The blood flow has the complex distribution in the aneurysmal region during the systolic period. Complex helical flow patterns are observed inside the aneurysm. Through an analysis of the hemodynamic characteristics, one may predict the rupture of the cerebral aneurysms.
Transactions of the Korean Society of Mechanical Engineers
/
v.9
no.6
/
pp.732-742
/
1985
Measurements of mean velocity and turbulence characteristics are obtained with a linearized constant temperature hot-wire anemometer in a two-dimensional turbulent jet discharging parallel to a flate. Wall static pressure distribution is also measure. The Reynolds number based on the jet nozzle width (D) is about 42,000 and the step height is 2.5D. The reattachment length is found to be 7.5D by using both wool tuft and oil methods. Upstream of the reattachment point, there exist double coherent structures and mean velocity, Reynolds stresses and triple product profiles are asymmetric about jet center line due to the influence of streamline curvature and recirculating flow region. Near the reattachment point, wall static pressure and turbulence quantities change its shape rapidly because of the large eddies by the solid wall. Especially, turbulence intensity has a maximum value in the reattachment regin, then decreases slowly in the redeveloping wall jet ragion. Downstream of X/D=14, a single large scale eddy structure is formed. Far downstream affer the reattachment(X/D.geq.18) mean velocity profile, the decay of maximum velocity and the variation of jet half width are nearly similar to those of plane wall jet, but the Reynolds stresses are higher than those of the latter.
This study addresses the behavior characteristics of diesel spray injected on the impinging disk with the room temperature. The models of impinging spray are the stick, the reflect and the wall jet model In the initiative of the fuel injection the impinging spray was the reflect model. because the momentum of droplets was very large. This model developed to the wall jet model according to the time approaches. On the low temperature disk the fuel film was made by the attachment of the droplets with low Weber number. The thickness of impinging spray was increased when the disk approached to the nozzle tip. Mathematical analysis for calculation with the behavior of impinging spray have to consider the reflecting effect and the influence of the fuel film.
Transactions of the Korean Society of Mechanical Engineers
/
v.8
no.2
/
pp.171-177
/
1984
균일하게 분포된 내부발열을 갖는 유체가 든 경사진(수평에서 45.deg.까지)정사각형 단면의 밀폐 공간 내에서의 2차원 자연대류 유동 및 열전달에 관한 수치적인 연구가 수행되었다. 4개 벽면온 도가 동일한 경계조건에서 내부발열로 인한 자연대류 유동이 Rayleigh수 1.5*$10^{5}$까지는 층 류유동 영역의 가정하에서 수치적으로 수렴되었다. 경사진 밀폐 공간에서의 유동형태 및 온도분 포는 수평인 경우에 비하여 윗쪽 벽면 근처에서 그 상이점이 많이 나타났다. 경사각도가 증가함 에 따라 평균 열전달율이 아랫쪽 벽과 오른쪽 벽에서 증가하였고 왼쪽 벽에서 감소하였으며 윗 쪽 벽에서는 거의 일정하였다.다.
The trapezoidal ribs had been installed in the retaining wall in order to reduce to flood damage in the impingement of mountain rivers. In this study, experiments in open channel with the trapezoidal ribs on sidewall were conducted to evaluate the effect of flow resistance by the trapezoidal shape. The hydraulic flow characteristics according to the flow rates were surveyed where the wall roughness is k-type that dimensionless spacings, ${\lambda}_{nv}$, are 6, 9, and 12. The flow-resistance factors such as roughness and friction coefficients increased generally with increase of the spacing of ribs. In high flow rate the friction coefficient showed the maximum value when ${\lambda}_{nv}$ is 9. Though the trapezoidal ribs has the relatively smaller flow resistance compared to the square ribs, their form drag accounted for mean 62% of the total flow resistance. It was confirmed that the optimal spacing of trapezoidal ribs to maximize the effect of flow resistance as the wall roughness increases are 9 to 12 times of the height of trapezoidal ribs.
발파시 공벽 주변에서 방사상으로 발생하는 무수한 균열들을 제어하고 일정한 방향으로 절단면을 형성하기 위해서 split tube를 이용한 발파 방법에 대한 현장 실험을 실시하였다. 현장 실험결과 절단면을 발달시키고자 하는 방향으로 제어할 수 있었다. 계산에 의한 발파압력과 제어된 균열면의 길이를 비교하였다. 현장 벤치 벽면에서 에멀젼 계열 폭약의 발파 압력이 700㎫이상일 경우 균열을 원하는 방향으루 제어할 수 있었을 뿐만 아니라, 공경의 30배까지 균열이 전파되었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.