• Title/Summary/Keyword: 백금 전극

Search Result 230, Processing Time 0.028 seconds

Continuous electricity generation in microbial fuel cells with non-precious metal catalysts (비귀금속촉매 미생물연료전지의 연속운전을 통한 전기 생산)

  • Moon, Chungman;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • In this study, continuous microbial fuel cells (MFCs) were operated using non-precious metal catalysts such as iron(II) phthalocyanine (FePc) and cobalt tetramethoxyphenylporphyrin (CoTMPP)) as alternative cathode catalysts for platinum. To evaluate MFCs performance, operational conditions of organic loading rate (OLR) (0.5~3 g COD/L/d) and hydraulic retention rate (HRT) (0.25~1 day) were changed. Power density of MFCs were determined by cathode electrode performance. The maximum power density was $3.3W/m^3$ with platinum at OLR 3 g COD/L/d. Given each HRTs at 1 g COD/L/d, FePc showed to be a better alternative for platinum than CoTMPP because the power density of MFC with FePc was similar to that of MFC with platinum. CoTMPP catalyst, however, showed the lowest power density due to increase of internal resistance during continuous operation.

A Performance characteristics of Pt/C Electrode prepared by Hot Pressing Method (Hot Pressing법에 의해 제조된 Pt/C 전극의 성능특성)

  • 김진수;서동우;설용건;이태희
    • Journal of Energy Engineering
    • /
    • v.1 no.1
    • /
    • pp.58-65
    • /
    • 1992
  • Pt loaded porous carbon Pt/C electrode was prepared by hot pressing process to enhance the electrode performance in PAFC (phosphoric acid fuel cell). By changing the hot pressing conditions and PTFE contents, Pt/C electrodes were prepared and the electrochemical characteristics of oxygen reduction and unit-cell performance were evaluated. The optimum condition of hot press to make electrode is 360$^{\circ}C$ and 10 kg/$\textrm{cm}^2$. Maximum performance was obtained at 30 wt% PTFE content in the catalyst layer with 80% utilization of platinum clusters. Unit-cell performance of hot pressed Pt/C electrode was 200 mA/$\textrm{cm}^2$ at 700 ㎷ and stable performance was maintained more than 200 hr.

  • PDF

Electric Characteristics of the MFC according to different electrode structures and materials (미생물 연료전지의 전극 재료와 구조에 따른 전기적 특성)

  • Choi, Kyu-man
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.1
    • /
    • pp.36-39
    • /
    • 2014
  • MFC(microbial fuel cell) is the device to produce the electricity by using the microbes which are living in the waste water. In this paper, the electric characteristics of the MFC were investigated according to each different structure and electrode materials. The voltage being reversed phenomenon was observed in the MFC which uses the cupper plate as the cathode material. This result comes from the oxidation reaction of the cupper plate electrode in this MFC. And this MFC has lower output voltage than one that has a platinum plate electrode. The smaller gap distance of the cupper plate electrode of the MFC showed the higher output voltage. The larger electrode area of the cupper plate electrode showed that the reaching time of the output voltage to the maximum value was delayed.

Study on Bio-compatible Packaging Technology for Non-enzymatic Glucose Micro-sensor Applications (마이크로 사이즈의 무효소 혈당센서 응용을 위한 생체적합한 패키징 기술에 관한 연구)

  • Park, Dae-J.;Lee, Yi-J.;Park, Jae-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.280-281
    • /
    • 2007
  • 본 논문에서는 생체 내에 삽입하거나 연속적으로 혈당을 모니터링하기 위하여 제작된 무효소 혈당세서의 바이오 패키징 및 특성 최적화에 관하여 고찰하였다. 3전극을 갖는 동일한 센서구조에서 sensitivity를 최대화하기 위해 평면형 백금전극을 사용한 센서, 메조포러스 구조가 작동전극에 형성된 센서, 메조포러스 구조가 작동전극과 보조전극에 형성된 무효소 혈당센서를 설계, 제작하고 비교하였다. 각각의 센서는 0.009${\mu}A$ $mM^{-1}cm^{-2}$, 5.46${\mu}A$ $mM^{-1}cm^{-2}$, 7.75${\mu}A$ $mM^{-1}cm^{-2}$의 sensitivity를 가졌다. 또한 생체 이식되었을 때 혈액 속에서 글루코스응답을 얻는 데에 있어 방해종인 Ascrobic Acid와 Acetaminophen의 반응을 최소화하고, 혈액 내의 단백질들이 전극에 엉겨 붙는 것을 막기 위해 생체 적합한 물질인 Nafion 을 패키징 멤브레인으로 적용하여 센서를 제작하였다. 이 센서는 0.36${\mu}A$ $mM^{-1}cm^{-2}$의 sensitivity를 가졌다.

  • PDF

Effect of fabrication conditions on microstructure and performance of electrodes for SOFCs (SOFC용 전극 제작 조건에 따른 전극 성능 및 구조 분석)

  • Lah, Se-Yun;Jee, Young-Seok;Lee, Yoon-Ho;Cho, Goo-Young;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.307-310
    • /
    • 2009
  • In order to develop SOFC cell performance, many kind of things were investigated. Electrode microstructure is the one of them therefore we focus on electrodes fabrication easily and efficiently. We can fabricate electrodes easily with Pt using DC magnetron sputtering and sintering. However sputtering is difficult to handle and to grow porous electrodes what we require. On the other hand sintering is much easier than sputtering to make porous and adhesive electrodes. So in this paper we deal with sintering and optimize to deposit electrodes conditions by analyzing electrode microstructure with sacnning electron microscopy(SEM) micrograph. Also, we compare electrochemical performance of cells fabricated by sputtering and sintering.

  • PDF

Electrochemical Impedance Analysis of Polyaniline-Film on Platinum Electrodes (백금 전극에 입힌 폴리아닐린의 전기화학적 임피던스)

  • Chon, Jung-Kyoon;Min, Byoung Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.9
    • /
    • pp.722-727
    • /
    • 1995
  • The electrochemical impedance spectra of polyaniline film prepared by cyclic voltammetry have been investigated in 0.1 M aqueous sulfuric acid solution. Charge transfer resistances were rather low at the oxidized states in agreement with the conductive behavior reported at these potentials. The corresponding exchange current densities were very high. Large values of capacitance associated with the polymer have been found which vary as a function of the electrode potentials. An equivalent electrical circuit has been deduced from the impedance data. It was therefore possible to obtain the parameters of the ionic mass transport within the film.

  • PDF

Electrode Performance of Pt-Cr-Ni Alloy Catalysts for Oxygen Electrode in Polymer Electrolyte Fuel Cell (고분자전해질형 연료전지에서 산소극을 위한 백금-크롬-니켈 합금촉매의 전극특성)

  • Sim, Jung-Pyo;Lee, Hong-Gi
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.831-837
    • /
    • 2000
  • To improve the catalytic activity of platinum on polymer electrolyte fuel cell(PEFC), platinum was alloyed with cobalt and nickel at various temperature. By XRD, it was observed the crystal structure of alloy catalysts were the ordered face centered cubic(f.c.c) due to the superlattice line at $33^{\circ}$. As heat-treatment temperature was increased, the particle size of alloys also were increased and the crystalline lattice parameters were decreased. According to the results from mass activity, specific activity and Tafel slope measured by cell performance test and cyclic voltammogram, the catalyst activities of alloys are higher than that pure platinum.

  • PDF

Preparation of Pt/porous Gold Electrode for CO Oxidation (CO 가스 산화를 위한 백금/다공성 골드 전극의 개발)

  • Shin, So-Hyang;Kim, He-Ro;Oh, Cheon-Seok;Ko, Jae-Wook;Kim, Young-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.27-32
    • /
    • 2011
  • Management of gas safety is becoming important with increasing use of gas facilities. U-safety system is being promoted as part of national management of gas, and thus real-time and in-situ gas sensor should be developed. Detection method for When the gas sensor is installed in gas conduit, explosion may be likely, because hydrocarbon gases is usually used the difference of thermal resistance between reference and working electrode. Therefore, it is required to detect the hydrocarbons, such as $CH_4$ and CO, at room temperature via electrochemically catalytic reaction. In this study, Pt nanoparticle was doped on the porous gold powder by electrolytic plating method, and then it was used as catalytic electrode for CO oxidation. For Pt/PAu electrode, approximately 21% of CO conversion was obtained. It is noted that Pt/PAu electrode could be used to react the oxidation of hydrocarbon gases at room temperature via applying of external voltage.

Convolutive Cyclic Voltammetry Investigation of Dicarboximide Laser Dye at a Platinum Electrode in 1,2-Dichloroethane (1,2-Dichloroethane 내 백금 전극에서의 dicarboximide 레이저 염료에 대한 convolutive 순환 전압-전류법 연구)

  • Al-Bishri, Hassan M.;El-Mossalamy, E.H.;El-Hallag, Ibrahim;El-Daly, Samy
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.169-176
    • /
    • 2011
  • The electrochemical investigation of N,N-bis (2,5-di-tert-butylphenyl)-3,4,9,10 perylenebis (dicarboximide) laser dye have been carried out using cyclic voltammetry and convolution - deconvolution voltammetry combined with digital simulation technique at a platinum electrode in 0.1 mol/L tetrabutyl ammonium perchlorate (TBAP) in solvent 1,2 dichloroethane ($CH_2Cl-CH_2Cl$). The investigated dye was reduced via consumption of two sequential electrons to form radical anion and dianion (EE mechanism). In switching the potential to positive scan, the compound was oxidized by loss of two electrons, which were followed by a fast aggregation process ($EC_1EC_2$ mechanism). The electrode reaction pathway and the chemical and electrochemical parameters of the investigated compound were determined using cyclic voltammetry and convolutive voltammetry. The extracted electrochemical parameters were verified and confirmed via digital simulation method.

Mediated Electrochemical Oxidation of High Molecular Weight PEGs by Co(III)/Co(II) and Fe(III)/Fe(II) Redox Systems (Co(III)/Co(II) 및 Fe(III)/Fe(II) 산화환원계에 의한 고분자량 폴리에텔렌글리콜류의 매개전해산화)

  • Park, Seung-Cho;Kim, Ik-Seong
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.206-211
    • /
    • 2005
  • Mediated electrochemical oxidation (MEO) of polyethylene glycols (PEGs) of molecular weight of 1000, 4000 and 20000, was carried out on both platinum (Pt) and titanium-iridium electrodes in 8.0 M nitric acid solution containing 0.5 M Fe(II) and Co(II) ion. The electrochemical parameters such as current densities, kinds of electrode, electrolyte concentration and removal efficiency were investigated in both Fe(III)/Fe(II) and Co(III)/Co(II) redox systems. The PEGs was decomposed into carbon dioxide by MEO in Fe(III)/Fe(II) and Co(III)/Co(II) redox system during 180 min and 210 min at the current density of $0.67A/cm^2$ on the Pt electrode. Removal efficiency of PEGs by MEO was better in Co(III)/Co(II) redox system than Fe(III)/Fe(II) redox system, indicating mediated electrochemical removal efficiency was 100%.