• Title/Summary/Keyword: 방전 전하량

Search Result 35, Processing Time 0.027 seconds

Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air (코로나방전에 의한 공중(空中)초음파 신호 특성)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.38-46
    • /
    • 1999
  • Measurerments of ultrasonic signals caused by corona discharges were perforrred by using an ultrasonic meeasurerment technique to analyze the deve1qxrent states of coronas in a high-voltage power apparatus. We also examined the relationship between discharge magnitude and ultrasonic pulse number to diagnose the deterioration of electrical insulation by corona discharges. From these results, it was found that ultrasonic signals due to corona discharges can be firstly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of ultrasonic signals was closely related to the current pulses by the corona discharges when ac voltages were gradually raised, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, tirre-delaying and directivity charocteristics of ultrasonic signals propagated to air by using ultrasonic oscillation and receiving systems are feJXlrt.ed as a basic data of ultrasonic measurements in out-door HV apparatus.aratus.

  • PDF

A Study of Penning gas for the improvement of luminance and luminous efficiency in AC plasma display panel (AC PDP에서의 최적의 페닝 방전가스 혼합비에 대한 휘도와 효율 향상에 관한 연구)

  • Lee, Jae-Kyung;Ham, Jung-Kook;Byun, Ki-Ryang;Kang, Jeong-Won;Hwang, Ho-Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1074-1077
    • /
    • 2003
  • 우리는 AC-PDP에서 휘도와 효율을 향상시키기 위하여 Ne-Xe(4%)와 He(7)-Ne(3)-Xe(3%)에 소량의 Ar 또는 Kr를 첨가하여 최적의 페닝 방전가스 혼합비를 연구하였다. 우리는 이것을 증명하기 위해 효율과 Q-V 방법을 이용하여 벽전하를 계산하였으며, 2차원 시뮬레이션에서의 결과값과 비교하였다. 200 Torr 압력에서 He-Ne-Xe 또는 Ne-Xe에 소량의 Ar(0.01-0.1%) 또는 Kr(0.01-0.1%)을 첨가시켰을 때, 우리는 20% 이상의 휘도의 증가와 25% 이상의 효율 증가를 발견하였고, 또한 벽전하도 25% 이상의 증가를 보였다. 400 Torr 압력에서 He-Ne-Xe-Kr(0.005%)에 소량의 Ar(0.005-0.1%)를 첨가시켰을 때는 8% 이상의 휘도의 증가와 18% 이상의 효율 증가, 12% 이상의 벽전하 증가를 확인하였다. 결론적으로 이 결과는 He, Ne, Ar, Kr 사이에 추가적인 페닝효과가 휘도와 효율을 향상시켰다는 것을 보여준다.

  • PDF

국내 초고압 케이블의 현황과 향후 과제

  • 황순철;최창수
    • 전기의세계
    • /
    • v.42 no.4
    • /
    • pp.5-12
    • /
    • 1993
  • 현재 우리나라 발전설비 용량은 2,100만kW에 이르나, 2001년에는 4,700만kW의 전력이 필요할 것으로 예측되며 전력수요의 급증에 따라 발전량의 증대가 불가피하고 전력의 질적 향상도 중요한 과제로 등장하고 있다. 양질의 전력공급 측면에서 정전사고가 발생시 우리 사회 전반적으로 미치는 파급효과는 막대하므로 전력설비의 보전과 절연진단 기술의 확립이 필요로 대두되고 있다. 그러므로 이에 따른 첨단 계측 기술의 도입과 컴퓨터를 이용한 - 부분방전의 계측과 해석 - 전기 TREE 시스템의 집중관리 - 절연진단 기술에의 컴퓨터의 이용 - 공간전하 분포의 측정 등의 절연진간 기술연구가 기업, 학계, 연구소 등이 공동으로 활발히 진행되고 있다.

  • PDF

원자로동특성 simulator에 관한 고찰

  • 한만춘
    • 전기의세계
    • /
    • v.12
    • /
    • pp.1-5
    • /
    • 1963
  • 원자로 출려그이 시간적 변화는 중성자의 흡수 및 누설량의 변화의 결과로 나타나는데 6개군의 지발중성자를 고려한 원자로동특성방정식은 잘 알려져 있다. 이들 식을 간단하게 풀기는 어려우므로 전자 analog회로로서 구성되는 simulator로서 해석하는 것이다. 지발중성자방사물질의 붕괴현상은 축전기에서의 전하의 충방전현상과 흡사하며 이들을 표현하는 방정식은 회로망의 전류, 전압을 나타내는 미분방정식과 유사하므로 동일한 과도현상을 나타낸다. 그러므로 노에 대한 각 parameter를 전기적 parameter에 대응시켜서 전기적으로 적분하여 전압을 검출하면 원자로의 출력을 나타낼 수 있게 된다. 이와같은 simulator로서는 지정회로망에 의한 회로가 여러 문헌에 소개되어 있으나 본고에서는 순수한 analog전자계산기에 의한 방법을 채택하였으며 이에 소요되는 연산요소는 시중에서 구할수 있는 부분품으로 조립하였다.

  • PDF

Negative Metal Sputter (DC sputtering)를 이용하여 증착된 MgO 박막의 특성

  • 이원정;안경준;여환욱;안병철;우형철;김성인
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.109-109
    • /
    • 2000
  • AC형 PDP에서 보호막은 방전시 내구성(내 sputter)이 약한 유전체를 보호함으로써 panel이 장시간동안 안정된 동작을 하게 하며, 방전시 2차 전자를 많이 방출함으로써 방전전압을 낮추는 기능을 갖는다. 또한 패널의 전압특성을 결정하고 수명을 크게 좌우하며 방전전극을 플라즈마 발광에 의한 이온 스퍼터로부터 보호하고 벽전하에 의한 메모리 기능을 가지도록 하는 역할도 하는 것으로 알려져 있다. 일반적으로 보호막의 재료로는 MgO, ZrO, CeO2등이 있으며 특히 MgO는 보호막으로 널리 쓰이고 있다. 일반적으로 MgO의 증착방법의 전자빔 증착, 스퍼터링, 이온 플레이팅법이 있으며 많은 연구자들이 이러한 증착방법에 성장된 박막들을 연구하고 있다. 그러나 Cs을 이용한 MgO의 증착방법은 그리 널리 알려져 있지는 않다. 따라서 본 연구에서는 Ar/O2/Cs을 이용하여 MgO박막을 sputtering 방법으로 증착하였으며 이들의 특성에 관하여 연구하였다. Target으로는 Mg을 사용하였으며 DC sputtering법으로 MgO를 증착하였다. 기판으로는 실리콘과 유리를 이용하였으며 가스로는 Ar과 O2를 이용하고 Cs의 첨가 유무에 따라 증착하였다. 또한 입력 전력, 공정압력, 그리고 O2 가스량에 따라 박막을 증착하였으며 이에 따른 증착속도, 결정성, 조성비를 $\alpha$-step, XRD, 그리고 XPS를 이용하여 측정하였다. CS 참가할 경우 Ar/O2 가스만을 이용하여 증착했을 때보다 증착속도는 증가하였으며 XRD 분석시 (111), (200) 방향으로 우선 성장하는 것을 관찰할 수 있었다.

  • PDF

Partial Discharge of Ignition Coil for Automotive (자동차 점화코일의 부분방전특성)

  • Shin, Jong-Yeol;Kim, Tag-Yong;Byun, Du-Gyoon;Kim, Weon-Jong;Lee, Soo-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.239-242
    • /
    • 2003
  • 자동차 점화장치는 전원으로부터 공급된 낮은 전압을 점화코일을 통하여 연소실의 혼합기를 연소시키기에 충분한 고전압을 발생시키는 장치이며, 점화장치의 핵심은 점화코일이다. 이 점화코일은 절연성능이 우수한 절연재료가 사용되지만 고전압의 발생으로 점화코일 내부에서 일어나는 전기적 열화로 인해 누설전류가 흐르게 되어 전기적 고장을 초래할 수 있다. 이로 인하여 절연재료의 수명은 단축되며, 또한 점화코일에 전류가 흐름으로써 코일 내부에서 발생하는 온도변화에 따른 절연열화로 점화코일의 성능이 저하될 수 있다. 따라서 본 연구에서는 점화코일에 사용되고 있는 절연재료에 전압이 인가될 때 발생할 수 있는 비파괴검사의 일종인 부분방전 측정을 통하여 전압변화에 따른 에폭시 성형 점화코일의 위상각($\Phi$) - 방전전하량(q) - 발생빈도수(n)의 특성 변화를 조사하고 분석함으로써 점화코일의 수명을 예측하여 자동차 점화장치의 성능진단과 정보제공을 자동차 전기장치의 발전에 도움이 될 것을 기대하며, 온도상승에 따른 점화코일의 부분방전 특성을 실험하고 분석하였다.

  • PDF

Response Characteristics of Acoustic Emission Sensor according to Partial Discharge Quantities (부분방전 전하량에 따른 음향방출 센서의 응답특성)

  • Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.383-387
    • /
    • 2010
  • The response characteristics of AE (acoustic emission) sensors with a coupled vibration mode and a non-coupled vibration mode were investigated according to PD(partial discharge) quantities in XLPE (cross linked polyethylene) sheets and craft papers immersed in insulating oil. The response voltages of a coupled vibration mode AE sensor were linearly proportional to the PD quantities up to 1,000 pC in XLPE sheets, while a non-coupled vibration mode AE sensor did not show the similar linearity. In case of a test of craft papers immersed in insulating oil, a linearity between response voltages and PD quantities was observed up to 550 pC, but after that, similar linearity between response voltage of any types of AE sensor and PD quantities was not shown.

Analysis of Current-Voltage Characteristics Caused by Electron Injection in Metal-Oxide-Semiconductor Devices (전자주입에 의해 야기되는 MOS 소자의 전류-전압 특성 분석)

  • Jeon Hyun-Goo;Choi, Sung-Woo;Ahn, Byung-Chul;Roh, Yong-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.11
    • /
    • pp.25-35
    • /
    • 2000
  • A simple two-terminal cyclic current0voltage(I-V) technique was used to measure the current-transients in metal-oxide-semiconductor capacitors. Distinct charging/discharging currents were measured and analyzed as a function of the hold time, the delay time, the gate polarity during the FNT electron injection, the injection fluence and the annealing time after the injection had stopped. The charge-exchange current was distinguished from total current-transients containing the displacement current components. Charging/discharging current caused by the charge exchange was strongly dependent not only on the density of positive charges in the $SiO_2$, but also on the density of interface traps generated during the FNT electron injection. Several tentative mechanisms were suggested.

  • PDF

A Study on the Short-Term Deterioration Test Method of MgO in AC PDP (AC PDP 보호막 MgO의 단시간 열화시험방법에 관한 연구)

  • 김윤기;허정은;김영기;이호준;박정후
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.578-583
    • /
    • 2002
  • For ac PDP, the lifetime should be guaranted over, 30000 hours. The lifetime is correlated with the deterioration characteristics for the weakest element in ac PDP. However, the short-term deterioration test method of the at PDP has not well developed. In this paper, a short term deterioration test method of a given element in the ac PDP is proposed. By this method, MgO deterioration characteristics are investigated. The deterioration rate is decreased with MgO thickness but it was almost saturated over 5000$\AA$.

Charge Storage Behavior of the Carbons Derived from Polyvinylidene Chloride-resin and Polyvinylidene Fluoride in Different pH Electrolytes (다른 pH의 전해질에서 polyvinylidene chloride-resin와 polyvinylidene fluoride로부터 합성된 다공성 탄소의 전하 저장 거동)

  • Sang-Eun, Chun
    • Composites Research
    • /
    • v.35 no.6
    • /
    • pp.394-401
    • /
    • 2022
  • Two polymer precursors, polyvinylidene chloride-resin (PVDC-resin) and polyvinylidene fluoride (PVDF), are assembled into the microporous carbon by pyrolysis. Microporous carbon is advantageous as an electrode for supercapacitors that store electric charges through ion adsorption/desorption. The pyrolysis also turns the various heteroatoms of two precursors into functional groups, contributing to the additional charge storage. The analysis of the porous structure and function group during carbonization are important to develop the carbon for energy storage. Here, we analyzed the functional groups of two polymer-derived carbons through X-ray photoelectron spectroscopy. The electrochemical properties of the functional groups were explored in various pH electrolytes. The specific capacitance of two carbons in the acidic electrolyte (1 M H2SO4) was improved compared to that in the neutral electrolyte (0.5 M Na2SO4) due to the faradaic charge/discharge reaction of the quinone functional group. In particular, the carbon electrode derived from PVDC-resin exhibits a lower capacity than the carbon from PVDF due to the small micropores. In the alkaline electrolyte (6 M KOH), the highest specific capacitance and rate capability were obtained among the three electrolytes for both electrodes based on the facile adsorption of the constituent electrolyte ions (K+, OH-).