• Title/Summary/Keyword: 방사선 피폭선량

Search Result 972, Processing Time 0.026 seconds

The Evaluation of Patients' Radiation Dose During TACE of Interventional Radiology (TACE의 중재적 시술시 환자의 피폭선량 평가)

  • Lee, Seung-Youl;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients' thyroid and genital gland. The average of ED (effective dose) was 18.43${\pm}$6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient.

Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation (갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산)

  • Ahn, Ki-Soo;Cho1, Hyo-Sung
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • According to the Para. 5 of Art 2 of the Korean Nuclear Safety Regulations, which was revised in 1999, internal dose assessment as well as external one should be performed by law for employees at a nuclear power plant from 2003, and their estimate errors should also be within 50%. Thus, more accurate internal dosimetry becomes important. Corresponding to such regulation revision, we are developing a more accurate thyroid-uptake internal dosimetric system and have developed a Monte Carlo simulation code, the so-called CALEFF, to calculate the detection efficiency of the dosimetric system. In this paper, we calculated detection efficiencies with various test conditions by using the CALEFF code and discussed their characteristics. We may use the detection efficiency calculated by the code in calibrating the thyroid internal dose from measured data.

  • PDF

Evaluation of Cancer Incidence Rate using Exposure Dose to Surrounding Normal Organs during Radiation Therapy for Prostate Cancer (전립선암의 방사선 치료 시 주변 정상장기 피폭선량을 이용한 암발생확률 평가)

  • Lee, Joo-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.351-356
    • /
    • 2022
  • The purpose of this study was to evaluate the cancer incidence rate and provide basic data by measuring the photoneutron dose generated during intensity-modulated radiation therapy and volumetric modulated arc therapy used in radiation therapy for prostate cancer. The optically stimulated luminescence albedo neutron dosimeter for neutron measurement was placed on the Rando phantom in the abdomen and thyroid and photoneutron dose generated was measured. As a result of the study, intensity-modulated radiation therapy (7 portal) was measured to be higher than volumetric rotational radiation therapy in both abdominal and thyroid locations. When the cancer incidence rate was evaluated using the nominal risk coefficient of ICRP 103, the cancer incidence rate due to exposure to the colon and thyroid during intensity-modulated radiation therapy was 9.9 per 1,000 people, and volumetric rotational radiation therapy for 1,000 people. It was 3.5 per person. Based on the principle of ALARA (As low as reasonably archievable), it is considered to be a guideline for minimizing the exposure dose to normal organs in the establishment of a radiation treatment plan.

A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT) (영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구)

  • Kim, Gha-Jung;Ryu, Jun-Min;Choi, Jun-Gu;Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.75-81
    • /
    • 2016
  • The recent radiation therapy field can provide treatment which guarantees a high degree of accuracy, due to patient set-up using various image guided radiation therapy(IGRT) instruments. But the additional absorbed dose to patient's normal tissues is increasing. Therefore, this study measured the absorbed dose to surrounding normal tissues which is caused by patient set-up using OBI, CBCT, ExacTrac, among various IGRT instruments. The absorbed dose to the head, the chest, the abdomen, and the pelvis from CBCT was 12.57 mGy, 20.82 mGy, 82.93 mGy, and 52.70 mGy, respectively. Also, the absorbed dose from OBI and ExacTrac ranged from 0.76 to 8.58 mGy and from 0.14 to 0.63 mGy, respectively. As a result, CBCT's absorbed dose was far higher than other instruments. CBCT's surface dose was far higher than others, too, but OBI's entrance skin dose was almost the same as CBCT's.

Measurement of the Spatial Dose Rates During PET/CT Studies (전신 PET/CT 검사에서 공간선량률 측정)

  • Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.257-260
    • /
    • 2006
  • In order to evaluate the exposure to the radiologic technologists from patients who had been administrated with radiopharmaceuticals, we measured the spatial dose rates at $5{\sim}300\;cm$ from skin surface of patients using an proportional digital surveymeter, 1.5(PET scan) and 4hr(bone scan) after injection. In results, the exposure to the technologists in each procedure was small, compared with the dose limits of the medical workers. However, the dose-response relationships in cancer and hereditary effects, referred to as the stochastic effects, have been assumed linear and no threshold models ; therefore, the exposure should be minimized. For this purpose, the measurements of spatial dose rate distributions were thought to be useful.

  • PDF

TLD dose variation of Magnetic Resonance Imaging Equipment (자기공명영상장비에서 열형광선량계의 선량 변화)

  • Je, Jaeyong;Kang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.473-476
    • /
    • 2012
  • The PET-MRI which has been installed and being managed recently uses both magnetic field and radiation. Most radiation workers wear a thermoluminescenct dosimeter (TLD) as a personal radiation dosimeter, and the TLD is affected both by a magnetic field and radiation. In this research, the same amount of X-ray was applied to 36 TLDs, and the changes in the dose of the 32 TLDs exposed to magnetic field at the location where its intensity of the magnetic resonance imaging (MRI) was about 5000 Gauss for eight hours with one-hour unit and that of the four TLDs not exposed to magnetic field were compared and checked. The measurement result showed that exposure dose of the TLD attached to the MRI changed irregularly depending on the amount of exposure time. Therefore, the TLD whose amount of changes little in the environment of a MRI is demanded to be developed.

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

Study on The Planning and Operation of Training Education in Radiologic Science for Reduced x-ray Exposure (방사선(학)과 실습교육에서 X선 피폭 감소를 위한 운영방법에 대한 연구)

  • Kil, Jong-Won;Park, Jung-Ho;Kim, Yong-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.174-179
    • /
    • 2014
  • In this study, we measure the radiation dose for every experiments performed during the training education in radiologic science and estimate the radiation dose to each participant in the training education to propose a safe curriculum including operation of the training education. In this paper, we optimized the three parameters and the results show the dramatically reduced radiation dose to each participant. The proposed arrangement of the subjects and operation of the training education will be very helpful to reorganize the curriculum and the subject operation and will protect the students from the radiation dose.

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF