• Title/Summary/Keyword: 방사선 촬영

Search Result 2,076, Processing Time 0.028 seconds

Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures (Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법)

  • Song, Joo-Hyoun;Lee, Joo-Yup;Yang, Sung-Cheol;Lee, Han-Yong;Kim, Jong-Ik
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.199-203
    • /
    • 2007
  • Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.

COMPARISON OF FOUR PANORAMIC DENTAL RADIOGRAPHIC SYSTEMS FOR TOOTH ANGULATION MEASUREMENT ACCURACY UNDER DIFFERENT TOLERENCES (치아장축 각도 측정 정확도에 대한 4종 파노라마 방사선 촬영기의 비교)

  • Burson Stacee Dumas;Farman Allan George;Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.317-326
    • /
    • 1994
  • Panoramic radiographs of a dry skull were used to evaluate the accuracy of four panoramic dental X-ray systems in determining tooth angulations in the buccal segments. The four machines evaluated were the Philips Oralix Pan DC, the GE panelipse, the SS White panorex 1, and the SS White Panorex 2. Panoramic radiographs were taken at six different patient positions for each machine to evaluate the effects of patient positioning on determining tooth angulations in the buccal segments. All of the machines studied showed a significant correlation between the mean radiographic estimates and the actual measurements regardless of positioning(p<0.05). With correct placement of the skull, the results were analyzed for an error tolerance of +/-3/sup 0/ between the actual measurements and the radiographic estimates for tooth angulation. The SS White Panorex 1 was accurate 74% of the time, the GE Panelipse was accurate 67% of the time, the Philips Oralix Pan DC and the SS White Panorex 2 were accurate 64% of the time. When an error tolerance of +/-5/sup 0/ was permitted, the accuracy was 89% for the SS White Panorex 1 and the GE Panelipse, 85% for the Philips Oralix Pan DC, and 81% for the SS White Panorex 2.

  • PDF

Radiography and Computed Tomography in Four Dogs with Lung Lobe Torsion (흉부 방사선 촬영과 컴퓨터단층촬영을 이용한 폐염전의 진단 4례)

  • Lee, Ki-Ja;Choi, Sung-Jin;Kim, Young-Hwan;Jeong, In-Seong;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.390-393
    • /
    • 2013
  • This case study describes the imaging features of radiography and computed tomography (CT) in four small breed dogs with lung lobe torsion. The medical records, thoracic radiographs and CT images of four dogs with confirmed lung lobe torsion were retrospectively reviewed. Pleural effusion and increased lobar opacity/density were seen on all CT and thoracic radiography in all four dogs. CT revealed narrowed/collapsed bronchus in all four dogs, while this was only appreciated on one thoracic radiography. The vesicular emphysema pattern was seen on four CT but only on three radiographic examinations. The specific findings of lung lobe torsion were vesicular emphysema and a narrowed/collapsed bronchus. These findings were more easily recognized on CT than with thoracic radiographs.

Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis (디지털 유방단층촬영의 피폭선량 경감을 위한 수동 촬영조건의 가이드라인 제시)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.483-491
    • /
    • 2016
  • The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure, the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients' Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

A comparative study of guiding methods for natural head posture in cephalometrics (두부방사선규격사진 촬영 시 유도방법에 따른 자연두부자세의 차이 및 재현성에 관한 연구)

  • Song, Jin-Myoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.341-350
    • /
    • 2005
  • The Purpose of this study was to compare the degree of vortical head rotation and to evaluate the reproducibility of natural Head posture (NHP) according to two guiding methods, the head posture aligner (HPA) method and the solf balance posture (SBP) method. The subjects consisted of 30 adults. On the first day. lateral and frontal cephalometric radiographs were obtained through the two guiding methods. One mouth later. lateral and frontal cephalometric radiographs were obtained again through both guiding methods. The degrees of vertical head rotation of both guiding methods were compared and the reproducibility was evaluated for each guiding method. A comparison of the degrees of vortical head rotation for the two methods revealed that the vertical head posture was lower in the SBP method than in the HPA method by an average of $2.79^{\circ}$. All measurements obtained using the HPA and SBP methods with a time interval of one north did not show any significant difierence in lateral and frortal cephalometric radiographs. The results of the present study suggest that the SBP method may be used as an alternative to the HPA method in case the HPA method can not be applied.

Comparisons and Measurements the Dose Value Using the Semiconductor Dosimeter and Dose Area Product Dosimeter in Skull, Chest and Abdomen (두개부, 흉부, 복부검사 시 반도체 선량계와 면적 선량계를 이용한 선량 값의 측정 및 비교)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Recently, There has been a growing interests in exposure dose to the patient who take a examination using radiation. The radiological technologists should be concerned about the exposure dose to patients and make an efforts to reduce the patient dose without decreasing the image quality. In the case of foreign, the exposure dose of general X-ray examination have been managed by standard value of exposure dose using dose area product (DAP) and entrance surface dose (ESD) dosimeter. This study is to compare DAP and ESD in skull anterior posterior (AP), chest posterior anterior (PA), and abdomen AP projections of phantom by using DAP and ESD dosimeter. In the results, there were no differences between DAP and ESD dosimeter.

Effects of a New Clinical Training Simulator for Dental Radiography using Augmented Reality on Self-efficacy, Interest in Learning, Flow, and Practice Satisfaction (증강현실형 치과방사선촬영 시뮬레이터의 개발 및 효과검증 : 자아효능감, 학습흥미도, 학습몰입도, 실습만족도를 중심으로)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1811-1817
    • /
    • 2018
  • The purpose of this study is to elucidate the effects of a new clinical training simulator for dental radiography using augmented reality (AR) on user learning context. To accomplish this purpose, we divided 217 dental hygiene students into two groups. The experimental group was presented with the new clinical training simulator for dental radiography using AR, and the control group was presented with task information using a textbook. The results showed that the experimental group presented the new clinical training simulator for dental radiography using AR had a higher level of self-efficacy, interest in learning, flow, and practice satisfaction compared with the control group shown the task information using a textbook. Therefore, the AR-based radiography simulator can be utilized in dental radiology practice education as an effective educational device.

Head & neck 환자의 방사선치료 시 tongue displacer 사용의 유용성 평가

  • 박용철;박영환;김경태;최지민
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2002
  • I. 목적 : 방사선 치료 시 최적화된 체내 선량분포를 얻는 것은 정상조직의 장애를 줄이고 종양선량을 높여 치료 효율을 극대화하는데 매우 중요하다. 본원에서는 병변 부위가 한쪽으로 치우친 head&neck 환자 치료 시 정상조직(tongue)을 보호하기 위해 tongue displacer를 만들어 사용한다. 이에 본 저자는 tongue displacer사용의 치료 유용성을 평가 하고자 한다. II. 대상 및 방법 : head & neck 치료 환자 중 병변 부위가 인체의 정중선(MSP)을 기준으로 한쪽으로 치우친 환자를 대상으로 하였다. 사용된 실험재료로는 C-T (high speed advantage, GE,US), RTP System (3D RTP system, prowess, US), 치과용 인상제 주입기(caulk system, quixx, japan), tongue displacer 등이 있다. 실험 방법은 모의 치료나 planning C-T를 시행하기 전에 치료 환자에게 사용할 개인용 tongue displacer를 치과용 인상제로 자체 제작하였다. 제작 후 모의 치료를 시행하고 3D plan을 하기 위해 planning C-T를 촬영하게 되는데 이때 tongue displacer사용 유. 무에 따라 각각 촬영을 하였다. 촬영된 두 가지의 CT영상을 prowess를 이용하여 3D plan을 하게 되는데 이때의 plan parameter나 beam direction등 plan에서의 모든 조건은 모두 동일시하고 선량 분포 및 DVH(dose volume histogram)값을 비교하였다. III. 결과 : tongue displace의 사용 유. 무에 따른 3D plan상의 DVH 비교 결과 tumor volume 주위의 다른 organ들은 모두 비슷한 양상의 DVH를 보였으나 tongue에 있어서 큰 변화를 보였다. tongue displacer를 사용 시, 미 사용시 보다 tongue의 위치를 변화시켜 치료 부위 외의 tongue에 받는 방사선 피폭 면적을 줄일 수 있었고 그 결과 DVH상의 $50\%$ volume이 $16\%$ 정도 줄어드는 것이 확인되었다. IV. 결론 : tongue에 방사선을 조사하면 방사선 부작용으로 mucositis, ulcer, hemorrhage등의 pain(동통)이 수반되므로 치료환자의 음식물 섭취불량으로 체증감소 등 전신 쇠약으로 이어질 수 있다. head & neck 환자 중에서 병소 위치가 한쪽으로 치우쳐서 있을 경우 인상제를 이용하여 tongue displacer를 만들어서 사용하면 tongue 의 위치를 변화시켜 방사선 조사 야에서 제외시켜준다. 그러므로 방사선 치료 시 tongue의 부작용을 최소화 할 수 있고 환자의 방사선 치료 만족도를 높일 수 있다고 사료된다.

  • PDF

Web Information of General Radiography an Cervical Vertebrae Fracture in Patients (경추골절 환자에서 방사선촬영 영상의 웹 정보화)

  • Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.123-128
    • /
    • 2005
  • It is necessary to obtain images of high diagnosis worth based on ability and skill of radiological technologist in case of acquisition of medical radiologaphy information. In addition, we need the various kinds of education considering individual radiological technologist variation and the organization of clinical education according to the large amount of learning and more expensive knowledge of radiology. In this paper, we implement CAI system for cervical vertebrae fracture radiograph with multimedia authoring tools on web environments. The CAI system can train a new radiological technologist and study a lot of radiological technologist on the cervical vertebrae fracture radiography acquisition based on more objective and systematical data in radiography room. The proposed CAI system is also expected as a useful program which can help to cure patients based on accurate diagnosis as well as obtain radiography more quickly using a technology of radiography acquisition for cervical vertebrae fracture.

  • PDF

National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.