• 제목/요약/키워드: 방사선오염

Search Result 321, Processing Time 0.023 seconds

Verification of the Contaminant Transport Numerical Model in Subsurface Soil (토양내 오염물이동 수치모델 검증)

  • Suh, Kyung-Suk;Kim, Eun-Han;Han, Moon-Hee;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.67-75
    • /
    • 2002
  • The groundwater flow and contaminant transport numerical models have been established for understanding the movement of pollutants in surface soil environment. The numerical solutions were compared with the analytic solutions for the verification and the application of the models. The numerical solutions from the groundwater and transport models agreed welt with analytic solutions. Especially, the results of groundwater flow model were validated in one- and two-dimensional heterogeneous media. Therefore, it will represent well the characteristics of the heterogeneous media in the field applications. Also, the phenomena of the pollutant dispersion represented quite well by the advection and the hydrodynamic dispersion in the results of the transport model. The important input factor is the choice of complicated boundary conditions in operating the numerical models. The numerical results are influenced by the choice of the proper boundary conditions.

Assessment of Counting Efficiency of a Whole Body Counter by Human Body Size and Standing Position Using Monte Carlo Method (몬테카를로 방법론을 이용한 측정 대상의 인체 크기와 측정 위치에 따른 전신계수기 계수효율 평가)

  • Pak, Min Jung;Yoo, Jae Ryong;Ha, Wi-Ho;Lee, Seung-Sook;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.46-53
    • /
    • 2014
  • For the case of radiation emergency, it is required to assess internal contamination of the public, including children as well as adults. The objective of the present study was to assess counting efficiency of a whole body counter by human body size and standing position of the measurement person. In this study, the FASTSCAN whole body counter used at National Radiation Emergency Medical Center of Korean Institute of Radiological and Medical Science was simulated by a radiation transport computer code. The simulation results of the counting efficiencies agreed well with measurements within the 2% of discrepancy for 4-year child and 5% for adults. The standing positions of the people were adjusted by body size to find the consistent trend of the counting efficiencies by human body size. Body size scaling factors of the whole body counter were derived to consider human body size and improve the measurement accuracy. The counting efficiency assessment methodology in this study can be successively used to improve the measurement accuracy when using a whole body counter for the case of radiation emergency.

An Investigation of Awareness on the Fukushima Nuclear Accident and Radioactive Contamination (후쿠시마 원전사고 및 방사능 오염에 대한 인식조사)

  • Ha, Jeong Chul;Song, Youngju
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Background: The objective of this study was to investigate Korean people's awareness about impact of the Fukushima nuclear power plant accident in Japan and radioactive contamination caused by it. Materials and Methods: The respondents of the survey were 600 adults who resided in the Seoul metropolitan area. Results and discussion: The survey results show that the majority of respondents were concerned about impact of radiation leakage that might have an effect on our environment. They were worried about radioactive contamination of foodstuffs, particularly fishery products and preferred to acquire information through TV(49.8%) or the Internet(31.3%). Meanwhile, respondents mentioned that the information on the Fukushima nuclear accident and radioactive contamination had not been sufficient and they didn't know well about the follow-up measures of the government on the accident. Most respondents answered that information on radioactive contamination levels and safety of foods and environment was most needed. Conclusion: The results of this study could be useful to enhance awareness on radioactivity and improve risk communication on nuclear power plant accidents.

Differences between Each Requirement for Radiation Safety Regulation Levels (방사선안전규제 요건별 인식도 차이)

  • Han, Eun Ok;Cho, Dae Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.219-225
    • /
    • 2012
  • This study makes differentiated regulations which can maximize the efficiency and convenience of radiation safety regulations by deriving evidence required to establish reasonable safety regulatory structure based on the determination of the levels of actual radiation safety regulations for radiation safety managers to perform radiation safety. We surveyed approximately 10% of radiation safety managers from domestic radiation-using organizations which was based on the Nuclear Safety Act and NUREG Vol. 1~21 of RS-G-1.9 (2005), NRC of IAEA, etc. The radiation safety managers showed the highest level of awareness on the requirements for exposure management ($3.32{\pm}0.910$), and the lowest level on the requirements for record keeping and storage of documents ($2.84{\pm}0.826$). Industrial organizations showed higher levels of awareness than medical organizations whose regulations should be more stringent on requirements of the status and management of radioactive sources, facilities, measurements, pollution control, measuring equipment, monitoring, education and training, and exposure management. This suggests that the actual regulations need to be re-evaluated because it is attributed to the regulations which are statistically significant difference of the levels of radiation safety regulations between industrial organizations and medical organizations. The process of developing regulatory requirements for each characteristic of domestic organizations needs to be done in future studies, as well as safety regulations to maximize convenience should be achieved if radiation safety regulations are conducted in consideration with the characteristics of each organization.

방사성환기설비 운전에 있어서의 부압변동 요인 및 대응 방안

  • 이강무;이범철;이영희;김태국;손종식;홍권표;김홍태
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.334-335
    • /
    • 2004
  • It is important that the contaminated air is not revealed to the outside of the facility. The inside of the facility should be classified into several zones according to the radioactivity and each zone should maintain tile differential negative pressure between the zones also. It is not easy to equilibrate the pressure during the operation. On the normal operation, the clogging of the HEPA filter and the opening of the doors/shutters influence very much. We could maintain the differential negative pressure between the zones by the constant watching and periodical replacement of the filters.

  • PDF

Experiments for the Characteristic Evaluation of Pollutant Transport in Tidal Influenced Region (조파역내 오염물 이동특성 평가 실험)

  • Park, Geon Hyeong;Kim, Ki Chul;Jung, Sung Hee;Suh, Kyung Suk
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.391-395
    • /
    • 2010
  • The characteristics for pollutant transport in tidal influenced area was investigated using tidal wave hydraulic scale model. Hydraulic scale model was composed of the tidal generator, attenuation area and channel. Also, wave height, current meter and conductivity meter were used with the measured instruments in hydraulic scale model. NaCl with a tracer was used to evaluate the advection phenomena under the different velocity profiles. The arrival time of the maximum concentration in the condition of the relatively fast velocity was measured about 30 seconds faster than ones in the conditions of low velocity. The measured concentrations of the tracer were shown in the detection points of the flow direction consecutively.

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

Investigation into the Actual State of Sanitary Management and Recognition Degree and Infection Level of Ultrasonographic Probes (초음파 탐촉자(Probes)의 위생관리 실태와 감염 인식도 조사 및 세균 오염도 측정)

  • Lee, Chang-Bok;Lee, Yang-Sub;Lee, Won-Hong;Cho, Cheong-Chan;Yoon, Hyang-Yi;Lee, Yong-Moon;Kim, Young-Keun;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.51-58
    • /
    • 2004
  • The gel, which is stained on probe after ultrasonography, is a good circumstances for proliferation of microbe. This study is to investigate into the actual state of sanitary management, recognition degree and infection level of ultrasonographic probes. We had performed a question with telephone to 42 hospitals in Seoul area from December in 2003. We also cultured to obtained a sample from three ultrasonographic units to investigate infection level of the probes. Sanitary management of the probes was performed in 21 hospitals with alcohol cotton. Sanitary management was performed daily in 14 hospitals. Most hospitals used cotton towel for clearing of gel stained on probes. Preventive management against infection was performed in 32 hospitals with vinyl cover, surgical glove, or alcohol sterilization etc. In the recognition degree on infection, the response that using method of ultrasonographic probes is insanitary were in 78.6%(33 hospitals), and 54.8%(23 hospitals) responded that bacteria can be infected through the probes. In the results of germiculture, bacteria and fungi were detected too number of to count, but escherichia coli was not detected. In conclusion, The gel stained on probe after ultrasonography must be cleared completely, and it is necessary that change of recognition on sanitary management.

  • PDF

A study on measurement of the pollution levels and disinfection of medical radiation shielding for lead apron (의료방사선 차폐용 납 가운의 오염도 측정 및 소독에 관한 연구)

  • Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.490-497
    • /
    • 2016
  • This study compared and analyzed the pollution levels of radiation shielding aprons and ways to sterilize them using 30 lead aprons. After collecting samples from the center of the lead apron, where contact is most frequent, experiments were conducted employing Coagula and Latex methods. Using the culture medium where bacteria grew, measurements of the pathogen count and identification were performed. The greatest number of pathogens were $7.16{\pm}10$, which were detected on the lead apron from general X-ray room #2, but there was no significant difference according to the facilities (p > 0.05). Compared to how many pathogens remained between using the disinfectant ethanol and tissue, the pathogens decreased by $0.01{\pm}0.4$ (p < 0.05) after using disinfectant ethanol and by $0.87{\pm}1.7$(p < 0.05) after using disinfectant tissue. The Pearson correlation test revealed a significant correlation (-0.296, p < 0.05) between them. According to this research, there were pathogens on the lead aprons and the number of pathogens was determined by statistical analysis. It is expected that the rate of radiology technologists, patients, and medical equipment infected by pathogens will be reduced by the proper use of sterilization with a disinfectant ethanol.

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF