• Title/Summary/Keyword: 막 손상

Search Result 436, Processing Time 0.031 seconds

Nano Ceramic Coating on Polypropylene Separator for Safety-Enhanced Lithium Secondary Battery (고안전성 리튬이차전지 구현을 위한 나노 세라믹 코팅 분리막 제조 및 전기화학특성 분석)

  • Lee, Jungmo;Jeon, Hyunkyu;Han, Taeyeong;Ryou, Myung-Hyun;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.2
    • /
    • pp.41-48
    • /
    • 2017
  • Herein, we have fabricated an ultrathin aluminum oxide ($Al_2O_3$) coated PP separator by using a RF sputter deposition process. Approximately 20 nm thickness coating layer on the bare PP separator was formed at the power of 55 W for 2 minutes without thermal damage. Whereas only permeability of the coated separator was degraded slightly, other properties such as thermal stability, uptake amount of liquid electrolyte, and ionic conductivity were improved comparing to the bare PP separator. As a result, an only 20-nm-thick $Al_2O_3$ coating layer could improve the rate capability compared with a bare PP separator under a high current density.

Protective Effects of 5-Androstendiol (5-AED) on Radiation-induced Intestinal Injury (방사선에 의한 장점막 손상에 대한 5-Androstenediol의 보호효과)

  • Kim, Joong-Sun;Lee, Seung-Sook;Jang, Won-Suk;Lee, Sun-Joo;Park, Sun-Hoo;Cho, Soo-Youn;Moon, Chang-Jong;Kim, Sung-Ho;Kim, Mi-Sook
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.141-146
    • /
    • 2010
  • Purpose: We examined the radioprotective effects of 5-androstendiol (5-AED), a natural hormone produced in the reticularis of the adrenal cortex, as a result of intestinal damage in gamma-irradiated C3H/HeN mice. Materials and Methods: Thirty mice (C3H/HeN) were divided into three groups; 1) non-irradiated control group, 2) irradiated group, and 3) 5-AED-treated group prior to irradiation. Next, 5-AED (50 mg/kg per body weight) was subcutaneously injected 24 hours before irradiation. The mice were whole-body irradiated with 10 Gy for the histological examination of jejunal crypt survival and the determination of the villus morphology including crypt depth, crypt size, number of villi, villus height, and length of basal lamina, as well as 5 Gy for the detection of apoptosis. Results: The 5-AED pre-treated group significantly increased the survival of the jejunal crypt, compared to irradiation controls (p<0.05 vs. irradiation controls at 3.5 days after 10 Gy). The evaluation of morphological changes revealed that the administration of 5-AED reduced the radiation-induced intestinal damages such as villus shortening and increased length of the basal lamina of enterocytes (p<0.05 vs irradiation controls on 3.5 day after 10 Gy, respectively). The administration of 5-AED decreased the radiation-induced apoptosis in the intestinal crypt, with no significant difference between the vehicle and 5-AED at 12 hours after 5 Gy. Conclusion: The results of this study suggest that the administration of 5-AED has a protective effect on intestinal damage induced by $\gamma$-irradiation. In turn, these results suggest that 5-AED could be a useful candidate for radioprotection against intestinal mucosal injury following irradiation.

Dependence of Thermal and Electrochemical Properties of ceramic Coated Separators on the Ceramic Particle Size (알루미나 크기에 따른 세라믹 코팅 분리막의 열적 특성 및 전기화학적 특성)

  • Park, Sun Min;Yu, Ho Jun;Kim, Kwang Hyun;Kang, Yun Chan;Cho, Won Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • Conventional lithium ion batteries suffer from notorious safety issues caused by inevitable lithium dendrite formation and proliferation during over/fast charging processes. The lithium dendrites or mechanical damage on the separator induce internal short circuit in LiB that generates extensive amount of heat within contacted electrode surfaces through the separator. During this heat generation, conventional polyolefin separators shrinks dramatically, and increasing short circuit pathway, that causes the battery to explode. To overcome this serious issue, ceramic coated separators are developed in commercial LiB to enhance thermal and mechanical stability. In this paper, various size(IL = 488.5 nm, I = 538.7 nm, S = 810.3 nm, D = 1533.3 nm) of $Al_2O_3$ particles are coated using styrene-butadiene rubber(SBR) / carboxymethyl cellulose(CMC) binder on PE separator to investigate its thermal stability and electrochemical effect on LiB coin cell with NCM cathode and Li metal anode.

Effect of Additives on Preparation of Porous Alumina Membrane by Anodic Oxidation in Sulfuric Acid (황산전해조에서 양극산화에 의한 다공성 알루미나 막의 제조시 첨가제의 영향)

  • Lee, Chang-Woo;Lee, Yoong;Kang, Hyun-Seop;Chang, Yoon-Ho;Hong, Young Ho;Hahm, Yeong-Min
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1030-1035
    • /
    • 1998
  • The porous alumina membrane was prepared from aluminum metal(99.8%) by anodic oxidation using DC power supply of constant current mode in an aqueous solution of sulfuric acid. To prevent the chemical dissolution of alumina membrane, $Al_2(SO_4)_3$, $AlPO_4$ and $Al(NO_3)_3$ which could be considered to supply $Al^{3+}$ ions were added to electrolyte solution at a reaction temperature of $20^{\circ}C$ and cumulative charge of $150C/cm^2$. Effects of these additives on the formation of porous alumina membrane were evaluated under various electrolyte concentration(5~20 wt%) and current densities($10{\sim}50mA/cm^2$). The membrane surfaces which were prepared in electrolyte solution with all the additives except $Al_2(SO_4)_3$ were damaged. However, when $Al_2(SO_4)_3$ was added to the $H_2SO_4$ solution, an uniform surface of porous alumina was obtained. Also, it was shown that the pore size of membrane was nearly independent on the quantity of $Al_2(SO_4)_3$ added at same electrolyte concentration and current density.

  • PDF

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (I): Evaluation of Acid Stability of Commercial Nanofiltration Membranes (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(I): 상용 나노여과 막의 산 안정성 평가)

  • Youm, Kyung-Ho;Shin, Hwa-Sup;Jin, Cheon-Deok
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • In this study the nanofiltration (NF) membrane treatment of a nitric acid waste solutions containing $Pb^{+2}$ heavy metal ion discharging from the etching processes of an electronics and semiconductors industry has been studied for the purpose of recycling of nitric acid etching solutions. Three kinds of NF membranes (General Electric Co. Duraslick NF-4040 membrane, Dow Co. Filmtec LP-4040 membrane and Koch Co. SelRO MPS-34 4040 membrane) were tested for their separation efficiency (total rejection) of $Pb^{+2}$ ion and membrane stability in nitric acid solution. NF experiments were carried out with a dead-end membrane filtration laboratory system. The membrane permeate flux was increased with the increasing storage time in nitric acid solution and lowering pH of acid solution because of the enhancing of NF membrane damage by nitric acid. The membrane stability in nitric acid solution was more superior in the order of Filmtec LP-4040 < Duraslick NF-4040 < SelRO MPS-34 4040 membrane. The total rejection of Pb+2 ion was decreased with the increasing storage time in nitric acid solution and lowering the pH of acid solution. The total rejection of $Pb^{+2}$ ion after 4 months NF treatment was decreased from 95% initial value to 20% in the case of Duraslick NF-4040 membrane, from 85% initial value to 65% in the case of SelRO MPS-34 4040 membrane and from 90% initial value to 10% in the case of Filmtec LP-4040 membrane. These results showed that SelRO MPS-34 4040 NF membrane was more suitable for the treatment of an acidic etching waste solutions containing heavy metal ions.

Simple Passivation Technology by Thermal Oxidation of Aluminum for AlGaN/GaN HEMTs

  • Kim, Jeong-Jin;An, Ho-Gyun;Bae, Seong-Beom;Mun, Jae-Gyeong;Park, Yeong-Rak;Im, Jong-Won;Min, Byeong-Gyu;Yun, Hyeong-Seop;Yang, Jeon-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.176-176
    • /
    • 2012
  • 본 연구는 GaN 기반의 전자소자의 표면 패시베이션 방법으로 열산화 공정을 이용한 알루미늄산화막 패시베이션 공정에 대하여 연구하였다. 결정질의 알루미늄산화물은 경도가 크고 화학적으로 안정적이기 때문에 외부 오염에 대한 소자 표면을 효과적으로 보호할 수 있으며, 열적안정성이 뛰어나 공정중 또는 공정 후의 고온 환경에서의 열 손상이 적은 장점을 가진다. 결정질 알루미늄산화막($Al_2O_3$)을 소자 표면에 형성하기 위해서 일반적으로 TMA (trimethlyaluminium)와 오존($O_3$)가스를 이용한 ALD 공정법이 사용되고 있으나 공정 비용이 비싸고 열산화막에 비해 전자 trapping이 많이 발생하여 전자이동도가 저하되는 단점이 있어, 본 연구에서는 열산화 공정을 이용하여 소자의 전기적 특성 저하를 발생시키지 않는 알루미늄산화막 패시베이션을 수행하였다. 실험에 사용된 기판은 AlGaN/GaN 이종접합 구조가 증착된 HEMT 제작용 기판을 사용하였으며 TLM 구조를 제작하여 소자의 채널 면저항 및 절연영역간 누설전류 특성을 확인하였다. TLM 구조가 제작된 샘플 위에 알루미늄을 100 ${\AA}$ 두께로 소자위에 증착하고 $O_2$ 분위기에서 약 $525{\sim}675^{\circ}C$ 온도로 3분간 열처리하여 알루미늄 산화막을 형성한 후 $950^{\circ}C$ 온도로 $N_2$ 분위기에서 30초간 안정화열처리 하여 안정한 알루미늄 산화막 패시베이션을 형성하였다. 알루미늄산화막 패시베이션 후 소자의 절연영역 사이의 누설전류는 패시베이션 전과 비슷한 크기를 나타냈고 패시베이션 후 채널의 면저항이 패시베이션 전에 비해 약 20% 감소한 것을 확인하였다. 또한 패시베이션된 소자와 패시베이션되지않은 소자에 대해 $900^{\circ}C$ 온도로 30초간 열처리한 결과 패시베이션 되지 않은 소자는 74%만큼 채널 면저항이 증가하였으며, 절연영역 누설전류가 다섯오더 크기로 증가한 반면 알루미늄산화막 패시베이션한 소자는 단지 13%의 채널 면저항의 증가를 나타내었고 절연영역 누설전류는 100배 감소한 값을 보여 알루미늄산화막 패시베이션이 소자의 열적 안정성을 향상시키는 것을 확인하였다.

  • PDF

Improvement of membrane operation for wastewater reuse (하수재이용 막여과 운영 효율 향상)

  • Chang, Dong Eil;Kim, Jae Hun;Lee, Sang Soo;Kim, Kyung Taek;Han, Bong Suk;Ha, Geum Yul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.327-327
    • /
    • 2021
  • 하수재이용에서 전처리 막여과 공정은 완벽한 고액분리로 인해 후단 역삼투막 손상을 줄일 수 있는 공정으로 각광을 받고 있다. 일반적으로 막여과 공정은 여과->물리세정->충진->여과 와 같은 제막사에서 제공하는 운전 사이클에 맞춰 적용하고 있으며 유지세정 역시 1회/일 또는 1회/주 단위로 정해진 범위에서 수행되고 있다. 이러한 운전 방식은 시시각각 변화하는 막 유입수질에 적절하게 대응하지 못해 장기적으로 막오염 발생에 따른 생산수량 감소는 물론 막오염 제거를 위한 화학세정 주기가 짧아져 전체적인 생산수량이 감소하는 원인이 되고 있다. Raffine(2012)에 따르면 가역적 막오염의 경우 Flux 증가에 큰 영향이 없으나 비가역적 막오염은 Flux 증가에 따라 급격히 증가한다고 보고하고 있으며 이는 제한된 분리막 면적당 처리수 생산량을 증가시키기 위해 비가역적 막오염의 발생량을 줄이는 것이 필요하며 이를 위해 주기적인 강화역세(Chemical Enhanced Backwashing, CEB)가 도입되고 효율적인 유지세정 방법에 대한 연구가 진행되고 있다. 당사에서는 일산에 있는 I 수질복원센터내에 25 m3/일 규모의 막여과 하수재이용 파일롯 플랜트를 설치하고 막여과 하수재이용 공정의 운영 효율을 높이기 위하여 W사에서 개발한 IntelliFluxControl(IFCr) 소프트웨어를 이용하여 하수재이용 막여과 성능을 확인 하였다. IFCr은 실시간으로 변화하는 수질에 따른 막오염 정도에 따라 역세 강도 및 빈도와 CEB 적용 정도를 변화시켜 분리막 운전의 효율을 높일 수 있는 운영 소프트웨어이다. I 수질복원센터의 하수 방류수를 막여과 유입수로 적용하여 40 LMH를 기준으로 IFCr을 적용하지 않은 경우 23.7일 운전 가능하였으나 IFCr을 적용한 경우 50일 연속 운전이 가능하였다. 또한 역세척수를 운전 기간 동안 약 50 m3을 사용한 반면 IFCr을 적용한 경우 이에 절반 수준인 24.1 m3 만 사용하여 회수율이 91%에서 95%로 증가한 것을 확인 할 수 있었다. 본 연구의 결과는 기존의 제막사에서 제시하는 막 공정 운영방법을 탈피하여 분리막이 갖고 있는 성능을 최대한 끌어 올릴 수 있는 연구 결과라고 판단되며 향후 스케일 업 연구를 통해 실제 플랜트에 적용 가능성이 확인 될 경우 시설의 설치 막모듈 개수와 유지관리비를 동시에 절감할 수 있는 기술이 될 수 있을 것이다

  • PDF

Changes of the Plastic Lens Properties Caused by Etching of the Coating Films (코팅막 식각으로 인한 플라스틱 렌즈의 특성 변화)

  • Moon, Byeong-Yeon;Hwang, Ki Ju;Lee, Yoon Jeong;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: We investigated the changes of plastic lens after etching of coating films by comparing uncoated lens. Methods: CR-39, middle index and high index lenses of 0 (zero) diopter were etched at $80^{\circ}C$ and room temperature using a coating remover, and then changes of refractive power, transmittance and surface morphology were investigated. Results: There were no differences in refractive power and transmittance between uncoated and etched lenses. The etching rate was similar in both CR-39 and middle index lens, but in the case of high index lens, it was slower and less steady than the others. From the SEM observation of lens surface, etching damage was found out on the surface of etched lens. It was shown the least damage in middle index lens but the most damage in high index lens. Conclusions: If the etching of coating films is demanded on condition that the surface of ophthalmic lenses are not damaged, a using of most adequate coating remover based on lens material should be considered, and a caution for proper etching conditions is required.

Evaluation of Growth Inhibition for Microcystis aeruginosa with Different Frequency of Ultrasonic Devices (초음파 장치의 주파수 변화에 따른 Microcystis aeruginosa의 성장억제 평가)

  • Jang, So Ye;Joo, Jin Chul;Kang, Eun Byeol;Ahn, Chae Min;Park, Jeongsu;Jeong, Moo Il;Lee, Dong Ho
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.3
    • /
    • pp.143-153
    • /
    • 2021
  • The growth inhibition effects of M. aeruginosa were verified using large volume (7.2 L) of algae samples and ultrasonication (high frequency of 1.6 MHz vs. low frequency of 23 kHz) in lab-scale experiment. The chlorophyll-a (chl-a) and cell number decreased gradually after 6 hr sonication with high frequency of 1.6 MHz whereas both decreased sharply after 6 hr sonication with low frequency of 23 kHz. Additionally, the first order degradation coefficient (k) values after sonication were greater than those during sonication. These results indicate that relatively low sonication energy per volume may affect the cell membrane and internal organs of M. aeruginosa in a slow and retarded manner and resulted in gradual decrease of cell numbers of M. aeruginosa. Based on the comparison of chl-a and cell number of M. aeruginosa after sonication, low frequency of 23 kHz is superior for growth inhibition of M. aeruginosa, since low frequency of 23 kHz easily penetrates the cell membrane and ruptures the internal organs including gas vesicles. As is evident in SEM and TEM images, ruptured cell membranes were clearly observed for low frequency of 23 kHz. Finally, the microcystin-LR in water is not detected and considered to be harmless in aquaculture systems.