• Title/Summary/Keyword: 마찰 항력

Search Result 42, Processing Time 0.03 seconds

Evaluation of Wind Force Coefficients of a Box-Type Girder Bridge with Noise Barriers (방음벽의 유무에 따른 박스형 거더교의 풍력계수 평가)

  • Jeong, Seung Hwan;Lee, Youngki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.627-634
    • /
    • 2018
  • In the study, computational fluid dynamics analysis was performed to estimate wind force coefficients for a box-type concrete girder bridge under the influence of wind. The drag, lift and pitching moment coefficients were obtained for the bridge section without noise barrier and compared with those of the bridge section with noise barriers of various heights. The shear stress transport $k-{\omega}$ turbulence model was employed to estimate the wind force coefficients, and the contribution of the friction drag force to the total drag force was investigated. It was found from the study that the drag force coefficients increased as the height of noise barrier increased when a wind blew horizontally, and that the contribution of the friction drag force was highest for the bridge section without noise barrier. It is concluded that the impact of the height of noise barriers should be considered in the design of bridges, and the friction force played an important role in evaluating wind forces on bridges.

Accelerometer-based Drag Measurement in a Shock Tunnel (충격파 터널에서의 가속도계 기반 항력 측정)

  • Jang, Byungkook;Kim, Keunyeong;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.489-495
    • /
    • 2020
  • An accelerometer-based system was designed and constructed for drag measurement in a shock tunnel. Drag coefficient of a conical model was measured under a Mach 6 flow condition. A simple and intuitive calibration method was presented to compensate for the friction force of the drag measurement system, and the results of the measurement were compared with computational fluid dynamics in which the simple conical model was analyzed. The influence of drag measurement interference by supports of various shapes was identified and the design was presented to minimize. The drag coefficient measurement using the modified support showed that the error of the drag coefficient by the support was decreased.

Numerical Experiment for Evaluation of Equivalent Resistance Coefficient according to Transverse Interval of Multi-Piers (다열기둥의 횡방향 간격변화에 따른 상당저항계수 산정 수치실험)

  • Kwon, Kab-Keun;Noh, Min;Choi, Jun-Woo;Yoon, Sung-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.586-591
    • /
    • 2009
  • 권 등(2008)은 수면보다 높은 정방형 다열기둥의 수리실험을 수행하여 바닥마찰과 구조물에 의한 흐름저항을 포함하고 항력상호작용계수가 적용된 Manning계수 형태의 상당저항계수 이론식을 제안하였으나 저항체의 횡방향 간격에 대해서는 충분한 연구가 수행되지 못하였다. 따라서 본 연구에서는 오리피스의 에너지 손실계수를 적용하여 횡방향 간격에 따른 항력상호작용계수식을 제안하였다. 또한 정방형 다열기둥의 다양한 횡방향 간격에 따른 흐름양상을 FLOW-3D를 이용한 수치실험을 수행하여 상당저항계수 n을 측정하였으며 수치실험 결과를 본 연구에서 제안한 횡방향 항력상호작용계수식이 적용된 이론식과 비교하였다. 이론식과 수치실험 결과는 잘 일치하였으며 이 결과로부터 본 논문에서 제안한 횡방향 항력상호작용계수식이 유효함을 확인하였다.

  • PDF

Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험)

  • Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.527-528
    • /
    • 2012
  • DBD (Dielectric Barrier Discharge) plasma actuator was designed for aerodynamic drag reduction using plasma flow control, and the drag reduction was measured by wind-tunnel tests using 2D test model. At the zero wind velocity, the plasma flow control had no effect on the drag reduction because the flow separation and surface friction drag were not occurred. At the wind velocity of 2m/s, 9.7% of drag was reduced by the flow separation control. The drag reduction decreased as the wind velocity increased.

  • PDF

Cavity as a New Passive Device for Reduction of Skin Friction and Heat Transfer (새로운 수동제어소자인 공동을 이용한 마찰력과 열전달 감소에 관한 연구)

  • Hahn Seonghyeon;Choi Haecheon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.463-466
    • /
    • 2002
  • In order to examine the possibility of using a cavity as a passive device for reduction of skin friction and heat transfer, an intensive parametric study over a broad range of the cavity depth and length at different Reynolds numbers is performed for both laminar and turbulent boundary layers in the present study. Direct and large eddy simulation techniques are used for turbulent boundary layers at low and moderate Reynolds numbers, respectively. for both laminar and turbulent boundary layers over a cavity, a flow oscillation occurs due to the shear layer instability when the cavity depth and length are sufficiently large and it plays an important role in the determination of drag and heat-transfer increase or decrease. For a cavity sufficiently small to suppress the flow oscillation, both the total drag and heat transfer are reduced. Therefore, the applicability of a cavity as a passive device for reduction of drag and heat transfer is fully confirmed in the present study. Scaling based on the wall shear rate of the incoming boundary layer is also proposed and it is found to be valid in steady flow over a cavity.

  • PDF

Mass Estimated Adaptive Controller for Nonlinear Friction Compensation in Linear Motor System (선형모터 시스템의 비선형 마찰 보상을 위한 질량 추정형 적응 제어기)

  • Lee, Jin-Woo;Sun, Jung-Won;Lee, Young-Jin;Suh, Jin-Ho;Lee, Kwon-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2558-2560
    • /
    • 2005
  • 본 논문에서는 마찰력과 질량은 수직항력에 의해 관계하고, 시스템 입출력 관계에서도 도출할 수 있음에 착안하여, LuGre 모델을 기반으로 하는 수직항력 관측이 가능한 보상기 적용과 동시에 제어 입력과 시스템 출력 관계를 적응규칙을 통해 질량추정기를 설계하여 제어 입력의 스케일로 사용함으로써 그 성능을 더욱 향상시키고자 하였다.

  • PDF

The Drag Reduction and Convective Heat Transfer Characteristics of Two-Phase Flow with Polymer Additives (고분자 물질 첨가에 의한 2상 유동의 마찰 항력 감소와 대류 열전달 특성)

  • Lee, Dong-Sang;Kim, Jae-Guen;Cha, Kyong-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.71-76
    • /
    • 2000
  • This experimental study was conducted to figure out the drag reduction and convective heat transfer in vertical downward two-phase flow with polymer additives. The drag reduction effect were analyzed by using the difference of the pressure drop between the flow with polymer additives and without it. Experimental results show that the pressure drop with polymer additives is less than the pressure drop without polymer in vertical downward two-phase flow. And the convective heat transfer has decreased with increasing the polymer concentration in vertical downward two-phase flow.

  • PDF

DNS of Drag-Reduced Turbulent Channel Flow due to Polymer Additives (폴리머 첨가제에 의한 항력감소 난류 채널 유동장의 직접수치모사)

  • Kim, Kyoung-Youn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.799-807
    • /
    • 2010
  • Direct numerical simulations (DNS) of turbulent channel flow for which the drag is reduced by using polymer additives have been performed by a pseudo-spectral method. The Reynolds number based on the friction velocity and half-channel height is 395, and the polymeric stresses due to the polymer additives are evaluated using the FENE-P (finitely extensible nonlinear elastic-Peterlin) model. The numerical results show that the drag reduction rate is significantly affected by the parameters used in the FENE-P model, such as the maximum extensibility and relaxation time of the polymer molecules. The turbulence data for both low- and high-drag reduction regimes are analyzed. In addition, the effects of FENE-P model parameters on the flow characteristics have been investigated for the same drag reduction rate due to the polymer additives. Finally, the present DNS results have been used to verify the correlation between rheological parameters and the extent of drag reduction, which was suggested by Li et al. (2006).