• Title/Summary/Keyword: 라이너벽면온도

Search Result 6, Processing Time 0.02 seconds

A Study on Film Cooling Characteristics of Liner in Liquid Rocket Engine (액체로켓엔진에서의 상온 기체를 이용한 라이너 막냉각 특성 연구)

  • Jeon, Jun-Su;Lee, Yang-Suk;Lee, Dong-Hyeong;Kim, Yoo;Ko, Young-Sung;Chung, Hae-Seung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.170-173
    • /
    • 2007
  • Cooling characteristics of a liner were investigated by a film cooling method using a gas nitrogen in a rocket engine. High temperature gas of this test was made by mixing liquid nitrogen with combustion gas of a liquid rocket. A supply system of gas nitrogen was additionally constructed to the existing test facility of liquid rocket engine, and a new test section consisted of a liner and a gas injection ring was manufactured. A 10 second firing test for finding cooling characteristics of the liner was successfully conducted and liner surface temperatures and hot gas temperature was obtained.

  • PDF

EXPERIMENTAL STUDY ON THE HEAVY-DUTY GAS TURBINE COMBUSTOR (산업용 가스터빈 연소기에 대한 실험적 연구)

  • Antonovsky, V.;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.142-149
    • /
    • 2000
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed in the scale 1:1. The model experiments were executed at a pressure smaller than in the real gas turbine. The combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure, and NOx emission were measured at partial and full load for both model and on-site testing. The comparison of these items of information, received on similar modes in the stand and field tests, has allowed the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

T800/AD6005계 복합재의 습기투과에 관한 연구

  • 박명규;류백능;최영보
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.35-36
    • /
    • 1997
  • 복합재는 강도가 높고 가볍기 때문에 최근 로켓의 연소관으로 널리 사용되고 있다. 그런데 이 복합재 로켓 연소관은 제조 후 대기 환경에 장기적으로 노출되어 있기 때문에 금속 연소관과는 달리 온도 또는 습도 등의 환경에 대한 영향을 고려해야 한다. 더구나 연소관은 내부에 추진제가 충전되어 있으므로 추진제의 기계적 특성이 습도에 민감함을 생각할 때 강도뿐만 아니라 습기의 투과도 또한 매우 중요한 고려 요소가 된다. 그러나 온/습도 변화에 따른 복합재 자체의 재료 특성 변화에 대한 연구는 많이 보고되었으나 습기의 투과 정도에 관한 연구는 자료가 미흡한 실정이다. 한편, 포화 함수율은 복합재에 따라서 차이가 있으나 T300/5208의 경우 문헌을 참조하면 20-$50^{\circ}C$에서 복합재 무게의 약 1.5% 정도이며 포화에 걸리는 시간은 약 100일 정도로 나타나 있다.본 연구에서는 수분이 복합재를 통하여 투과되는 정도를 고찰하기 위하여 $20^{\circ}C$,95%RH의 온/습도를 유지하는 수조를 제작하였고, 이 수조내에 보관한 복합재 연소관의 실린더 벽면으로 투과되는 습기를 측정하기 위하여 연소관 내에 습도 센서를 투입하여 상대습도를 직접 측정하였다. 복합재 연소관이 로켓에 사용될 때는 연소관 외부에 페인트로 피막 처리하고 연소관 내부에도 추진제와의 사이에 라이너가 접착되어 있어서 수분 침투 및 온도 등의 외부 환경조건에 견디기에 더 양호한 조건이나 본 연구에서는 복합재 자체의 특성을 고찰하기 위하여 섬유를 에폭시에 함침시켜 winding한 상태 그대로의 복합재 연소관 시료를 사용하였다. 습기의 투과는 내부에 라이너/인슐레이션이 피복되거나 또는 추진제가 충전된 경우 많은 감소효과를 보였다. 순수 복합재 연소관의 경우 수조에 넣고 평형에 도달한 후로부터 약 8개월의 습기 투과 상태를 볼대 벽면을 통하여 들어가는 water vapor flux는 $20^{\circ}C$,95%RH 에서 평균적으로 9.3163$\times$$10^{-8}$g/$m^2$sec로 나타났다. 이때 습기가 투과되는 연소관이 국지점을 평판으로 가정하고 Fick's law를 이용하여 구한 습기에 대한 복합재의 확산계수는 D=2.5$\times$$10^{-6}$$mm^2$sec였으며, 이는 다른 graphite/epixy 복합재의 확산계수와 유사한 값을 나타내고 있다. 또한 추진제가 충전된 연소관을 절단하여 밀폐한 후 95%RH 습도 조건에 보관함으로써 연소관 내부의 추진제 기계적 특성에 미치는 침투된 습기의 영향도 함께 고찰하였다. 추진제에 따라 차이는 있겠으나 추진제가 충전된 연소관은 순수 복합재 연소관에 비해 습기의 투과 정도가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.

  • PDF

Research Activities of Transpiration Cooling for High-Performance Flight Engines (고성능 비행체 엔진을 위한 분출냉각의 연구동향)

  • Hwang, Ki-Young;Kim, You-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.10
    • /
    • pp.966-978
    • /
    • 2011
  • Transpiration cooling is the most effective cooling technique for the high-performance liquid rockets and air-breathing engines operating in aggressive environments with higher pressures and temperatures. When applying transpiration cooling, combustor liners and turbine blades/vanes are cooled by the coolant(air or fuel) passing through their porous walls and also the exit coolant acting as an insulating film. Practical implementation of the cooling technique has been hampered by the limitations of available porous materials. But advances in metal-joining techniques have led to the development of multi-laminate porous structures such as Lamilloy$^{(R)}$ fabricated from several diffusion-bonded, etched metal thin sheets. And also with the availability of lightweight, ceramic matrix composites(CMC), transpiration cooling now seems to be a promising technique for high-performance engine cooling. This paper reviews recent research activities of transpiration cooling and its applications to gas turbines, liquid rockets, and the engines for hypersonic vehicles.

Research Activities of Transpiration Cooling for Liquid Rocket and Air-breathing Propulsions (액체로켓과 공기흡입식 추진기관을 위한 분출냉각의 연구동향)

  • Hwang, Ki-Young;Kim, You-Il;Song, In-Hyuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.235-240
    • /
    • 2010
  • Transpiration cooling is the most effective cooling technique for liquid rocket and air-breathing engines operating in aggressive environments with higher pressures and temperatures. Combustor liners and turbine vanes are cooled by the coolant(air or fuel) passing through their porous walls and also the exit coolant acting as an insulating film. However, its practical implementation has been hampered by the limitations of available porous materials. The search for more practical methods of increasing the internal heat transfer within the walls has led to the development of multi-laminate porous structures, such as Lamilloy$^{(R)}$ and Transply$^{(R)}$. This paper reviews recent research activities of transpiration cooling for the propulsions of liquid rocket, gas turbine, and scramjet.

  • PDF

The Effect of Shading on Pedestrians' Thermal Comfort in the E-W Street (동-서 가로에서 차양이 보행자의 열적 쾌적성에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.60-74
    • /
    • 2018
  • This study was to investigate the pedestrian's thermal environments in the North Sidewalk of E-W Street during summer heatwave. We carried out detailed measurements with four human-biometeorological stations on Dongjin Street, Jinju, Korea ($N35^{\circ}10.73{\sim}10.75^{\prime}$, $E128^{\circ}55.90{\sim}58.00^{\prime}$, elevation: 50m). Two of the stations stood under one row street tree and hedge(One-Tree), two row street tree and hedge (Two-Tree), one of the stations stood under shelter and awning(Shelter), while the other in the sun (Sunlit). The measurement spots were instrumented with microclimate monitoring stations to continuously measure microclimate, radiation from the six cardinal directions at the height of 1.1m so as to calculate the Universal Thermal Climate Index (UTCI) from 24th July to 21th August 2018. The radiant temperature of sidewalk's elements were measured by the reflective sphere and thermal camera at 29th July 2018. The analysis results of 9 day's 1 minute term human-biometeorological data absorbed by a man in standing position from 10am to 4pm, and 1 day's radiant temperature of sidewalk elements from 1:16pm to 1:35pm, showed the following. The shading of street tree and shelter were mitigated heat stress by the lowered UTCI at mid and late summer's daytime, One-Tree and Two-Tree lowered respectively 0.4~0.5 level, 0.5~0.8 level of the heat stress, Shelter lowered respectively 0.3~1.0 level of the heat stress compared with those in the Sunlit. But the thermal environments in the One-Tree, Two-Tree and Shelter during the heat wave supposed to user "very strong heat stress" while those in the Sunlit supposed to user "very strong heat stres" and "exterme heat stress". The main heat load temperature compared with body temperature ($37^{\circ}C$) were respectively $7.4^{\circ}C{\sim}21.4^{\circ}C$ (pavement), $14.7^{\circ}C{\sim}15.8^{\circ}C$ (road), $12.7^{\circ}C$ (shelter canopy), $7.0^{\circ}C$ (street funiture), $3.5^{\circ}C{\sim}6.4^{\circ}C$ (building facade). The main heat load percentage were respectively 34.9%~81.0% (pavement), 9.6%~25.2% (road), 24.8% (shelter canopy), 14.1%~15.4% (building facade), 5.7% (street facility). Reducing the radiant temperature of the pavement, road, building surfaces by shading is the most effective means to achieve outdoor thermal comfort for pedestrians in sidewalk. Therefore, increasing the projected canopy area and LAI of street tree through the minimal training and pruning, building dense roadside hedge are essential for pedestrians thermal comfort. In addition, thermal liner, high reflective materials, greening etc. should be introduced for reducing the surface temperature of shelter and awning canopy. Also, retro-reflective materials of building facade should be introduced for the control of reflective sun radiation. More aggressively pavement watering should be introduced for reducing the surface temperature of sidewalk's pavement.