• Title/Summary/Keyword: 디스크각도

Search Result 28, Processing Time 0.018 seconds

Flow Characteristics in the Downstream Region of a Butterfly Valve with Various Disk Opening Angle (디스크 회전각에 따른 버터플라이 밸브 하류에서의 유동특성)

  • Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.267-272
    • /
    • 2006
  • Butterfly valves have been used for shut-off and throttling-control application in many industrial fields. Recently, they are frequently used for cooling water, oil system and ballast piping system of many larger vessels. They are especially suited for flow throttling control of heat exchangers in engine room. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics of butterfly valve inserted within circular pipe. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal systematic performance of the butterfly valve, wall pressure was measured at 6 points along the pipe by digital manometer. As the valve position moves to the closed side, flow separation increases and persists its tendency downstream until smoothly uniform flow developed. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 60 degrees.

  • PDF

Characteristic Analysis of Rotor System due to the Positioning Angles of HDD Supported by Fluid Dynamic Bearings (유체동압베어링으로 지지되는 HDD 의 장착각도에 따른 회전부의 특성해석)

  • Hwang, Choongman;Jang, Gunhee;Lee, Jihoon;Lee, Minho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.986-992
    • /
    • 2014
  • This research investigates experimentally and numerically the tilting angle, eccentricity ratio, flying height of axial direction, friction torque, and critical mass of the HDD disk-spindle system due to HDD positioning angle. The tilting angle and the eccentricity ratio are the maximum when the HDD positioning angle is $90^{\circ}$ respect to horizontal position because the external force in radial direction and the torque applied to the rotating part are the maximum when the HDD positioning angle is $90^{\circ}$. The flying height increases with the increase of the HDD positioning angle because the direction of gravity applied to the rotating part changes. The friction torque increases with the increase of the HDD positioning angle until it becomes $60^{\circ}$, and decreases with the increase of the HDD positioning angle after it becomes $60^{\circ}$. The stability is the maximum when the HDD positioning angle is $90^{\circ}$.

  • PDF

Case Report of 6 Patients Not Improved after Conservative Treatment of Herniated Lumbar Intervertebral Disc (요추간판탈출증으로 보존적 치료후 호전되지 않는 환자 6 례 보고)

  • Lee, Sam-Ro;Kim, Hyun-Jung;Byun, Jae-Young;Ahn, Soo-Gi;Lee, Jong-Deok
    • Journal of Acupuncture Research
    • /
    • v.17 no.3
    • /
    • pp.265-276
    • /
    • 2000
  • Objectives : The purpose of this study is to observe the clinical characteristics of 6 patients who were not improved after admitted conservative treatment in this 311 patients. Methods : We retrospectivety reviewed 311 patients of Herniated Lumbar Intervertebral Disc which undenvent admitted conservative treatment from November 1997 to June 2000. 311 patients were diagnosed by computed tomography or magnetic resonance imaging in addition to physical examination. Other complications were not detected in 311 patients with Hemiated Lumbar Intervertebral Disc. In case that the scoliosis appeared to caused by severe pain, we included this scoliosis patient with the object of survey. Results : 1. In 6 patients who were not improved, 4 patients were large herniation and 2 patients were medium herniation. 2. In all of 6 patients, the angle of straight leg raising test was low and was not imporved unril discharge. 3. X-ray findings showed straightening in all of 6 patients, disc space narrowing in 3 of 6 patients. 4. X-ray findings showed scoliosis in 3 of 4 patients who were severe pain. 5. The onset was relarively long from 30 days to 7 years. 6. The age was relatively young from 10's to 30's. 7. The adimission date was ralatively long from 32 days to 105 days. Conclusions : In 6 patients, there were observed much volume of disc herniation, low angle of straight leg raising test, young people in an age group, straightening of x-ray finding.

  • PDF

Experimental Study of Characteristics of Assist Gas in Laser Machining Using Supersonic Rectangular Nozzle (초음속 사각노즐을 이용하는 레이저 가공 보조가스의 특성에 관한 실험적 연구)

  • Son, Sang-Hyuk;Jun, Dong-Yeon;Lee, Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.233-240
    • /
    • 2012
  • An experimental study to improve the impingement characteristics of the assist gas in laser cutting was carried out. For various assist-gas pressures, and locations and installation angles of the nozzle, the characteristics of the impingement of the jet from a supersonic rectangular nozzle were compared to those previously observed for typical circular nozzles. Schlieren flow visualizations and Pitot pressure measurements downstream of the kerf surface were utilized for this purpose. The present rectangular supersonic nozzle decreased the strength of the Mach disc occurring at the corner of the kerf surface, and thus, could weaken the separation of the assist gas on the kerf surface and increase the Pitot pressures downstream compared to conventional circular nozzles.

Servo control for shift-multiplexed holographic data storage by using a dome-type glass (돔 유리를 이용한 위치이동 다중화 홀로그램 정보저장장치용 서보 컨트롤)

  • 김성필;송석호;오차환;김필수;김지덕;이홍석
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.74-78
    • /
    • 2004
  • We propose a servo control method using a dome-type glass in shift-multiplexed holographic data storage. We frist store live 2-D data by shift-multiplexing in a holographic disk with 5% variation in their. diffraction efficiencies. During read-out of the stored data, the servo control using the dome glass correctly compensates mechanical errors of the disk; the error of $\pm$0.2$^{\circ}$and run-out error of $\pm$50 ${\mu}{\textrm}{m}$. Use of the dome-type glass in servo control makes a pickup module more compact in size and easier to control than the previous method using parallel glass plate [Sungphil Kim, et al., Hankook Kwanghak Hoeji, Vol. 14, No. 1, pp.58-64, 2003].

An Experimental Study on the Effects of Tabs and Small Proturbances Inside Nozzle on Supersonic Jet Flowfield (노즐 탭과 노즐 내부 낮은 돌출부가 초음속 제트유동장에 미치는 영향에 관한 연구)

  • Jin, Won-Jin;Cho, Chang-Kwon;Lee, Yeol;Yoon, Woong-Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.24-31
    • /
    • 2002
  • The effects of vortex generators, in the form of small delta-shaped tabs or thin tapes at an axi-symmetric supersonic nozzle exit, on the characteristics of supersonic jet flowfields are investigated by Schlieren images and Pitot-tube measurements. Small tabs as small as 1 % of the nozzle exit area can introduce streamwise vortices and produce a significant effect on the jet flowfield downstream of the nozzle. The effect is stronger for the cases of under-expanded jet than over- and perfect-expanded cases, introducing a larger flow entrainment. The effects of the angle of tabs with respect to the flow direction are also investigated, and for over-expanded jet cases, it is found that the tabs bended toward upstream can weaken the interaction strength and remove the Mach disc in the jet flowfield. Introduction of small proturbances inside the nozzle surface by attachment of thin tapes is also found to change the pressure distribution in the circumferential direction of the flowfield. Its effect is also found to be dependent on the jet expansion ratio.

Influence of Design Variables on Flow Characteristics of Poppet Valve using Analysis of Means (평균분석을 이용한 설계변수가 포핏 밸브의 유동특성에 미치는 영향)

  • Jeong, Ja-Young;Choi, Eun-Ho;Kang, Young-Jin;Noh, Yoojeong;Lim, O-Kaung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.239-248
    • /
    • 2017
  • According to the structure, solenoid valve can be categorized as spool valve or poppet valve. While various research on spool valve which has simple structure and fine susceptibility to contamination has been conducted, poppet valve which has less susceptibility to contamination and advantage in a long time operation still need much research because of its complicated structure. In order to design the poppet valve, various parameters such as the diameter of the poppet, the angle of the poppet, the diameter of the disk, the spring stiffness, the spring preload and flow path structure should be considered. Conventional studies on poppet valve usually take only one design parameters and did not much focused on the effect of the parameters on flow characteristics. In this paper, the change of the flow characteristics according to the design parameters of the poppet valve for 3/2Way solenoid valve is analyzed. The previous studies and the results of initial model analysis was referred for the selection of the design parameters. The effects of design parameters on maximum pressure, minimum pressure, and pressure drop was examined using analysis of means(ANOM).

COLOR DIFFERENCE OF THE DENTAL COMPOSITES MEASURED BY DIFFERENT COLOR MEASURING INSTRUMENTS (복합레진 색상의 측정 기기에 따른 차이)

  • Park, Su-Jung;Noh, Eun-Young;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.199-207
    • /
    • 2009
  • The objective of this study was to evaluate the effect of color measuring instrument by measuring the color of dental composite resins. Nine shade light cured composite resin disks were prepared (diameter : 15 mm, thickness : 4 mm). CIE $L^*a^*b^*$ color scale of each disk was measured with 3 different types of spectrophotometer [MiniScan XE plus (Model 4000S, Hunter Lab, USA), CM-3500d (Minolta, Japan) and Specbos 2100 Miniature VIS Reflection spectrometer (Serial No: 319416, JETI Technishe VIS Instrumentic GmbH. Germany)]. Miniscan XE Plus and CM-3500d using identical measuring geometry with different size of viewing aperture. But Specbos 2100 using different measuring geometry. Within the limitation of this study, there were color difference (${\Delta}E^*$) from 2.4 to 7.8 between Miniscan XE Plus and CM-3500d, but $L^*$, $a^*$, $b^*$ values showed the high correlation. However, there were great color difference (${\Delta}E^*$) in the extent of about 20 between instruments with the different measuring geometry. Therefore, color scale measured by color measuring instrument should be used as a relative value rather than an absolute value in the field of dentistry.