Abstract

According to the structure, solenoid valve can be categorized as spool valve or poppet valve. While various research on spool valve which has simple structure and fine susceptibility to contamination has been conducted, poppet valve which has less susceptibility to contamination and advantage in a long time operation still need much research because of its complicated structure. In order to design the poppet valve, various parameters such as the diameter of the poppet, the angle of the poppet, the diameter of the disk, the spring stiffness, the spring preload and flow path structure should be considered. Conventional studies on poppet valve usually take only one design parameters and did not much focused on the effect of the parameters on flow characteristics. In this paper, the change of the flow characteristics according to the design parameters of the poppet valve for 3/2Way solenoid valve is analyzed. The previous studies and the results of initial model analysis was referred for the selection of the design parameters. The effects of design parameters on maximum pressure, minimum pressure, and pressure drop was examined using analysis of means(ANOM).

솔레노이드 밸브는 구조에 따라 스풀 밸브와 포핏 밸브로 구분된다. 구조가 단순하고 오염에 민감한 스풀 밸브에 대하여 연구가 많이 진행되고 있는 반면 오염에 덜 민감하고 장시간 작동에 용이한 포핏 밸브는 구조가 복잡하여 여전히 많은 연구가 필요하다. 포핏 밸브를 설계하기 위해서 고려해야 하는 사항으로 포핏의 직경, 포핏의 각도, 디스크의 지름, 스프링 강성, 스프링 예하중, 유로 구조 등 다양한 설계변수가 있다. 기존 연구에서는 설계변수를 한가지로 선정하여 연구가 진행되었고, 설계변수가 포핏 밸브의 유동특성에 미치는 영향에 대한 연구가 부족하다. 본 논문에서는 3/2Way 솔레노이드 밸브용 포핏 밸브의 설계변수 변화에 따른 유동특성의 변화를 분석하였다. 포핏 밸브의 설계변수 선정은 선행연구된 사례와 초기모델해석결과를 참고하여 진행하였다. 그리고 설계변수에 따른 최대압력, 최소압력, 압력강하의 영향을 평균분석(ANOM)을 사용하여 살펴보았다. 향후 3/2Way 솔레노이드 밸브용 포핏 밸브를 설계할 때 주효과를 파악하여 설계변수 선정에 사용하면 효율적인 설계변수 선정이 가능할 것으로 예상된다.

Keywords

References

  1. Choi, Y.H., Yun, Y.N., Ham, Y.B., Jo, J.D. (2002) Characteristics Analysis of Direct-operated Poppet Valve, Korean Soc. Precis. Eng., pp.729-732.
  2. Lisowski, E., Czyzycki, W.,Rajda. J. (2013) Three Dimensional CFD Analysis and Experimental Test of Flow Force Acting on the Spool of Solenoid Operated Directional Control Valve, Energy Convers. & Manag., 70, pp.220-229. https://doi.org/10.1016/j.enconman.2013.02.016
  3. Hong, S.H., Son, S.I., Kim, K.W. (2013) Comparative Study of the Navier-Stokes Equation & the Reynolds Equation in Spool Valve Analysis Considering Cavitation, Korean Soc. Tribol. & Lubr. Eng., 29(5), pp.275-285.
  4. Versteeg, H.K., Malalasekera, W. (2015) An Introduction to Computational Fluid Dynamics: The Finite Volume Method, Hongpub, Seoul, p.549.
  5. Kim, J.O., Baek, S.H., Kim, T.W., Kang, S.M. (2013) Multi-objective Optimization of Marine 3/2WAY Pneumatic Valve using Compromise Decision-Making Method, J. Korean Soc. Manuf. Process Eng., 12(2), pp.80-89.
  6. Lee, C.S., Kang, B.S., Ko, S.H. (2014) Study on the Flow Characteristics in Accordance with the Shape of the Spool Pneumatic Solenoid Valve, Korean Soc. Precis. Eng., p.103.
  7. Park, J.H., Kim, J.M., Lee, C.J., Kang, J.H. (2012) A Study on the Flow Characteristic of High Pressure 3/2-Way Valve for a Ship Engine, J. Korean Soc. Manuf. Process Eng., 11(3), pp.35-40.
  8. Park, T.J. (2011) Lubrication Characteristics of Laser Textured Parallel Thrust Bearing : Part 3 - Effect of Number of Dimples, KSTLE, 27(6), pp.302-307.
  9. Park, U.H., Lee, H.W., Choi, S.C., Jeng, K.H. (2003) Effects of Control Valve Trim Characteristics due to a Pressure Drop, Korean Soc. Automot. Eng., pp.167-174.
  10. Rexroth Bosch Group Catalogue (2007) 2/2, 3/2 and 4/2 Directional Seat Valve with Solenoid Actuation, Type M-.SED, RE 22049/07.09.
  11. Riccardo Amirante, Luciano Andrea Catalano, Carlo Poloni & Paolo Tamburrano (2014) Fluid-dynamic Design Optimization of Hydraulic Proportional Directional Valves, Eng. Optim., 46(10), pp.1295-1314. https://doi.org/10.1080/0305215X.2013.836638
  12. Shin, M.J., Jeong, Y.H., Park, T.J., Kwon, G.R. (2014) Influence of Poppet Shape on The Flow of a Direct-Operated Pressure Relief Valve, Korean Soc. Comput. Fluids Eng., pp.84-85.
  13. Yun, S.N., Jeong, H.H., Seo, J.K., Ham, Y.B. (2010) A Study on Relative Stabillity for Poppet Valve with Drain Orifice, Korea Soc. Fluid Power & Constr. Equip., pp.12-17.