• Title/Summary/Keyword: 등요

Search Result 168,800, Processing Time 0.168 seconds

Application and Analysis of Ocean Remote-Sensing Reflectance Quality Assurance Algorithm for GOCI-II (천리안해양위성 2호(GOCI-II) 원격반사도 품질 검증 시스템 적용 및 결과)

  • Sujung Bae;Eunkyung Lee;Jianwei Wei;Kyeong-sang Lee;Minsang Kim;Jong-kuk Choi;Jae Hyun Ahn
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1565-1576
    • /
    • 2023
  • An atmospheric correction algorithm based on the radiative transfer model is required to obtain remote-sensing reflectance (Rrs) from the Geostationary Ocean Color Imager-II (GOCI-II) observed at the top-of-atmosphere. This Rrs derived from the atmospheric correction is utilized to estimate various marine environmental parameters such as chlorophyll-a concentration, total suspended materials concentration, and absorption of dissolved organic matter. Therefore, an atmospheric correction is a fundamental algorithm as it significantly impacts the reliability of all other color products. However, in clear waters, for example, atmospheric path radiance exceeds more than ten times higher than the water-leaving radiance in the blue wavelengths. This implies atmospheric correction is a highly error-sensitive process with a 1% error in estimating atmospheric radiance in the atmospheric correction process can cause more than 10% errors. Therefore, the quality assessment of Rrs after the atmospheric correction is essential for ensuring reliable ocean environment analysis using ocean color satellite data. In this study, a Quality Assurance (QA) algorithm based on in-situ Rrs data, which has been archived into a database using Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-optical Archive and Storage System (SeaBASS), was applied and modified to consider the different spectral characteristics of GOCI-II. This method is officially employed in the National Oceanic and Atmospheric Administration (NOAA)'s ocean color satellite data processing system. It provides quality analysis scores for Rrs ranging from 0 to 1 and classifies the water types into 23 categories. When the QA algorithm is applied to the initial phase of GOCI-II data with less calibration, it shows the highest frequency at a relatively low score of 0.625. However, when the algorithm is applied to the improved GOCI-II atmospheric correction results with updated calibrations, it shows the highest frequency at a higher score of 0.875 compared to the previous results. The water types analysis using the QA algorithm indicated that parts of the East Sea, South Sea, and the Northwest Pacific Ocean are primarily characterized as relatively clear case-I waters, while the coastal areas of the Yellow Sea and the East China Sea are mainly classified as highly turbid case-II waters. We expect that the QA algorithm will support GOCI-II users in terms of not only statistically identifying Rrs resulted with significant errors but also more reliable calibration with quality assured data. The algorithm will be included in the level-2 flag data provided with GOCI-II atmospheric correction.

The Innovation Ecosystem and Implications of the Netherlands. (네덜란드의 혁신클러스터정책과 시사점)

  • Kim, Young-woo
    • Journal of Venture Innovation
    • /
    • v.5 no.1
    • /
    • pp.107-127
    • /
    • 2022
  • Global challenges such as the corona pandemic, climate change and the war-on-tech ensure that the demand who the technologies of the future develops and monitors prominently for will be on the agenda. Development of, and applications in, agrifood, biotech, high-tech, medtech, quantum, AI and photonics are the basis of the future earning capacity of the Netherlands and contribute to solving societal challenges, close to home and worldwide. To be like the Netherlands and Europe a strategic position in the to obtain knowledge and innovation chain, and with it our autonomy in relation to from China and the United States insurance, clear choices are needed. Brainport Eindhoven: Building on Philips' knowledge base, there is create an innovative ecosystem where more than 7,000 companies in the High-tech Systems & Materials (HTSM) collaborate on new technologies, future earning potential and international value chains. Nearly 20,000 private R&D employees work in 5 regional high-end campuses and for companies such as ASML, NXP, DAF, Prodrive Technologies, Lightyear and many others. Brainport Eindhoven has a internationally leading position in the field of system engineering, semicon, micro and nanoelectronics, AI, integrated photonics and additive manufacturing. What is being developed in Brainport leads to the growth of the manufacturing industry far beyond the region thanks to chain cooperation between large companies and SMEs. South-Holland: The South Holland ecosystem includes companies as KPN, Shell, DSM and Janssen Pharmaceutical, large and innovative SMEs and leading educational and knowledge institutions that have more than Invest €3.3 billion in R&D. Bearing Cores are formed by the top campuses of Leiden and Delft, good for more than 40,000 innovative jobs, the port-industrial complex (logistics & energy), the manufacturing industry cluster on maritime and aerospace and the horticultural cluster in the Westland. South Holland trains thematically key technologies such as biotech, quantum technology and AI. Twente: The green, technological top region of Twente has a long tradition of collaboration in triple helix bandage. Technological innovations from Twente offer worldwide solutions for the large social issues. Work is in progress to key technologies such as AI, photonics, robotics and nanotechnology. New technology is applied in sectors such as medtech, the manufacturing industry, agriculture and circular value chains, such as textiles and construction. Being for Twente start-ups and SMEs of great importance to the jobs of tomorrow. Connect these companies technology from Twente with knowledge regions and OEMs, at home and abroad. Wageningen in FoodValley: Wageningen Campus is a global agri-food magnet for startups and corporates by the national accelerator StartLife and student incubator StartHub. FoodvalleyNL also connects with an ambitious 2030 programme, the versatile ecosystem regional, national and international - including through the WEF European food innovation hub. The campus offers guests and the 3,000 private R&D put in an interesting programming science, innovation and social dialogue around the challenges in agro production, food processing, biobased/circular, climate and biodiversity. The Netherlands succeeded in industrializing in logistics countries, but it is striving for sustainable growth by creating an innovative ecosystem through a regional industry-academic research model. In particular, the Brainport Cluster, centered on the high-tech industry, pursues regional innovation and is opening a new horizon for existing industry-academic models. Brainport is a state-of-the-art forward base that leads the innovation ecosystem of Dutch manufacturing. The history of ports in the Netherlands is transforming from a logistics-oriented port symbolized by Rotterdam into a "port of digital knowledge" centered on Brainport. On the basis of this, it can be seen that the industry-academic cluster model linking the central government's vision to create an innovative ecosystem and the specialized industry in the region serves as the biggest stepping stone. The Netherlands' innovation policy is expected to be more faithful to its role as Europe's "digital gateway" through regional development centered on the innovation cluster ecosystem and investment in job creation and new industries.

The Effects of Entrepreneurship Mentoring on Entrepreneurial Will and Mentoring Satisfaction: Focusing on Opus Entrepreneurship Education (창업 멘토링 기능이 창업의지와 멘토링 만족도에 미치는 영향: 오퍼스 창업교육을 중심으로)

  • Kim, Ki-Hong;Lee, Chang-Young;Joe, Jee-Hyung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.3
    • /
    • pp.211-226
    • /
    • 2023
  • As we transition into the post-COVID era, economic activities that were stagnant are regaining momentum. In particular, there is a growing trend of technology entrepreneurship driven by the opportunities of digital transformation in the Fourth Industrial Revolution. However, entrepreneurship education content is struggling to keep up with the rapid pace of technological change. This study aims to emphasize the importance of entrepreneurship mentoring as a crucial component of entrepreneurship education content that requires adaptation and advancement due to the increasing demand for technology entrepreneurship. This study redefines startup mentoring, which is differentiated from general mentoring, at the present time when the demand for startups, which increases with the declining employment rate, increases, and the development of quality startup education contents and securing professional startup mentors are required. According to the start-up stage, it is divided into preliminary entrepreneurs and early entrepreneurs, and the effect of entrepreneurship knowledge and self-efficacy among start-up mentoring functions on entrepreneurial will and mentoring satisfaction is improved by empirically researching the effects of start-up mentoring functions in the case of initial entrepreneurs as a moderating effect. To confirm the importance of entrepreneurship mentoring effect for. To this end, among the mentoring functions, entrepreneurship knowledge and self-efficacy were set as independent variables, and entrepreneurial will and mentoring satisfaction were set as dependent variables. The research model was designed and hypotheses were established. In addition, empirical analysis was conducted by conducting a questionnaire survey on trainees who received entrepreneurship mentoring education at ICCE Startup School and Opus Startup School. To summarize the results of the empirical analysis, first, among the entrepreneurship mentoring functions, entrepreneurship knowledge and self-efficacy were analyzed to have a significant positive (+) effect on entrepreneurial will. Second, among the entrepreneurship mentoring functions, entrepreneurship knowledge and self-efficacy were analyzed to have a significant positive (+) effect on mentoring satisfaction. Third, it was analyzed that entrepreneurship had no significant moderating effect on entrepreneurial knowledge and entrepreneurial will. Fourth, it was analyzed that entrepreneurship had no significant moderating effect on mentoring satisfaction. Fifth, it was found that entrepreneurship had a significant moderating effect between self-efficacy and will to start a business. As a result of the research analysis, the first implication is that the mentoring function in start-up education is analyzed to produce meaningful results for both the initial entrepreneurs and the prospective entrepreneurs in the will to start a business and satisfaction. . Second, it was analyzed that there was no significant relationship between whether a business was started and the mentoring function and effect. However, it was analyzed that the will to start a business through improvement of self-efficacy through mentoring was significantly related to whether or not to start a business. turned out to be helpful. Many start-up education programs currently conducted in Korea educate both early-stage entrepreneurs and prospective entrepreneurs at the same time for reasons such as convenience. However, through the results of this study, even in small-scale entrepreneurship mentoring, it is suggested that customized mentoring through detailed classification such as whether the mentee has started a business can be a method for successful entrepreneurship and high satisfaction of the mentee.

  • PDF

Changes in Exhibitions on the History of Balhae in Russian Museums and the Characteristics of Exhibition Narratives - with the focus on the Federal State Budgetary Institution of Culture "The Vladimir K. Arseniev Museum and Reserve of Far East History" - (러시아 박물관의 발해사 전시 변화와 전시 내러티브의 특징 - 아르세니예프 V.K. 국립극동역사보호지구 통합박물관을 중심으로 -)

  • JEONG Yoonhee
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.54-79
    • /
    • 2024
  • The purpose of this research is to fill the vacuum created by the tendency of bias towards China among the curators of Korean museums who plan exhibitions focusing on Balhae, and to share with researchers in the countries concerned various supplementary research materials that could deepen their understanding of the history of Balhae. These materials are based on analyses of the details of exhibitions about Balhae held in a particular Russian museum and the characteristics of and changes in the museum's operational policy. Thus, this research focuses mainly on the permanent and special exhibitions held by the Far East History Museum and Reserve, whose collection represents the archaeological achievements of Russia regarding the history of Balhae. The first part of the research focuses on the layout of the exhibitions presented by the museum and the museum's operational policy. It reveals that the museum's permanent exhibitions follow a diachronic arrangement of the local history, while the first and second special exhibitions featured exhibits that were selected from the collections of the Russian Academy of Sciences and arranged according to specific themes. It also examines the museum's policy for operating the exhibitions, focusing on the operational rules, the human resources deployed to run them, and the related educational and PR programs. The second part of the research examines such issues as local politics, economy, education and culture related to the exhibitions on Balhae's history, and connects them to the background and development of the exhibitions. This study reveals that the permanent exhibitions were intended to promote historical awareness of the local area by museum visitors, particularly those who visited the exhibitions while the city was hosting important events such as international summits. It also reveals that the museum's first special exhibition led to the promotion of Korea-Russia cooperation on exchanges in the fields of culture and tourism, whereas the second special exhibition involved no PR efforts or related events, which was probably due to the changes that have occurred in the relationship between Russia and its neighboring countries since then. The final part of the study focuses on the characteristic features of the exhibition narratives, and compares school textbooks on local history and history books for general readers with the contents of the exhibitions. The analysis of the narratives based on the development of time shows that the history of the Mohe (or Malgal) tribes has been combined with that of Balhae, while they are treated separately in school textbooks. As regards political history, the narrative was largely focused on officials in Balhae's central government rather than on Mohe warriors in the border areas. The maps of Balhae presented in the exhibitions highlight the importance of accumulating empirical data. As for the exhibition of material cultures, this study suggests that the museums should obtain more archaeological floral and faunal remains related with agriculture and hunting. It also points out that the narrative on the theme of foreign relations deals with the archaeological relics of Unified Silla together with those of the Turkic tribes. As for the theme of philosophy and culture, the narrative focused on the state ceremonies and rituals of Goguryeo, a theme that has attracted little attention among Korean academic circles and which consequently requires further study. In conclusion, this study is meaningful in that it suggests a number of research topics regarding the development of exhibitions and exhibition narratives about the history of Balhae by a prestigious Russian museum that specializes in this subject.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

REPORT OF EXPERIENCE WITH KIMURA'S DISEASE (기무라씨 질환, 5 예 보고)

  • Seel David J.;Park Yoon-Kyu;Lee Kwang-Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1989
  • Kimura's Disease is a chronic inflammatory and proliferative condition producing subcutaneous masses especially in the head and neck area. This report of our experience with 5 patients with this disease is the first in the Korean surgical literature. Kimura's Disease is thought to be part of the larger spectrum of the entity known as angiolymphoid hyperplasia with eosinophilia (ALHE). It is characterized pathologically by hyperplastic lymphoid follicles, eosinophilic infiltration, and vase 비 ar proliferation. It produces masses which are most common in the area of the parotid, submandibular gland and upper neck. These masses occupy the subcutaneous tissues but also extend into salivary tissue and into upper neck nodes. One of our patients had masses in the groin. The tumors are extremely vascular due to the presence of new proliferative vessels and sinusoids. The average age of our 5 patients was 35, but all but one case were younger than 38 years of age. The male: female ratio was 3 : 2, and the average duration of symptoms was 5,2years. All patients had peripheral blood eosinophilia. All had multiple masses, sometimes symmetrical. The management was surgery alone in one case, surgery and steroids in one case, surgery and radiotherapy in two cases, and all three modalities in one case. The relationship of this entity to ALHE and our experience in the management of this disease are presented. A clinicopathological discrepancy alerted us to the existence of Kimura's Disease. A nineteen-year old male presented with subcutaneous masses over both mastoid areas present for 3 years (Case III). When biopsy on each side was reported as 'eosinophilic granuloma' we submitted the slides to an internationally expert pathologist. Symmetrically occurring tumors in the peri-parotid subcutaneous areas did not fit any category of neoplasm or granuloma known to us. The diagnosis, made by Dr. Gist Fan at the Ochsner Clinic, was Kimura's Disease. We found two additional cases in a review of soft tissue eosinophilic granuloma previously reported at Presbyterian Medical Center, and since then have diagnosed two new cases. These five cases constitute the basis for this, the largest series to be reported in Korea. These vascular, tumor-like lesions of the skin, subcutaneous areas and subjacent structures of the head and neck have been a variety of names, such as angiolymphoid hyperplasia with eosinophilia, eosinophilic hyperplastic lymphogranuloma, angioblastic lymphoid hyperplasia with eosinophilia, histioid hemangioma, and epithelioid hemangioma. The history of this disease spectrum dates back to 1937 when Kimm and Szeto (1) reported 7 cases of 'eosinophilic hyperplastic lymphogranuloma' in the Proceedings of the Chinese Medical Journal. In 1948 Kimura and his associates(2) reported additional cases in Japan under the title 'On the unusual granulation combined with hyperplastic changes of lymphatic tissue.' From then until 1966 several hundred cases were reported in China and Japan. The first report from the West was by Wells and Whimster(3) in the British Journal of Dermatology, in 1969. These authors coined the term, angiolymphoid hyperplasia with eosinophilia (ALHE). Since that time a debate has ensued as to whether Kimura's Disease and ALHE are distinct entities, or whether Kimura's is part of the larger spectrum of ALHE, perhaps a later or advanced phase. From the clinical perspective, surgeons should be aware of the diagnosis of Kimura's Disease not only as part of the differential diagnosis of head and neck tumors but also because these lesions are indolent, and generally require conservative surgical removal as part of the management program. CASE I. A 37-year-old female company employee presented in August 1982 with submental swelling of 12 years' duration and with inguinal swelling of 7 years' duration. The submental mass measured 5x5cm. and the inguinal mass was 8x4cm. in size. Peripheral eosinophilia varying from 14% to 40% was found. On August 20, 1982, the submental mass was removed and a superficial groin dissection was done. In May 1983 an intraoral lesion of the palate was removed. The patient is free of disease. CASE II. A 23-year-old unemployed man visited this hospital for the first time in July, 1984, with swelling of the right cheek present for 6 years. The mass was soft and ill-defined but measured 10x20cm. and extended from the submandibular upper neck to the zygomatic arch, and from the mastoid to the cheek, over the parotid gland. Eosinophilia varying from 27% to 29% was noted in the peripheral blood. On March 21, 1986, the lesion was resected. The procedure comprised an extended superficial parotidectomy from the temporalis fascia to the upper neck. Post-operatively radiotherapy 3000 rad tissue dose was administered using the 6 MeV linear accelerator. The patient remains free of disease. CASE III. A 19-year-old student came to the clinic with masses over both mastoid areas, present 3 years. On the right there were two adjacent lesions, one over the mastoid, the other in the upper jugular level of the neck. On the left it was a single mass over the mastoid. Eosinophilia varied from 13 to 32% in the peripheral blood, and 11.6% in the bone marrow. Incisional biopsy revealed 'eosinophilic granuloma' and a trial of predisolone was employed. The mass increased in size so a small dose of radiation (600 rads) was used, with substantial regression,. The lesion on the left was excised and follwed by 1000 rads radiotherapy. Finally recurrent tumor on the right side was removed on November 5, 1985. The patient remains free of disease. CASE N. A 29-year-old local merchant had had swelling of both upper necks since childhood. At the time of his first visit on March 17, 1986, the right submandibular mass measured 5x3.5cm. and the ,right upper neck and parotid tail mass measured 2.5cm. On the left there were masses in the upper neck, the largest of which measured 2.5cm, and of the parotid tail, 2.0cm. in size.(See Fig. 1) Peripheral eosinophilia of 39% was recorded. Left side partial parotidectomy and resection of the upper neck and subdigstric mases was done on May 2, 1986. The mass involving the right parotid tail and upper neck nodes was removed on Angust 7,1986. Postoperatively the patient was placed on prednisolone 30 mg. per day. No definite masses are palpable. CASE V. A 66-year-old housewife informed us, at the time of her first visit in May, 1986, that she had had multiple neck masses since 10 years ago. On the right side there was a 2.5cm. subcutaneous mass of the upper neck, over the upper jugular chain. On the left there was a 9x4.5cm. mass involving the entire parotid, the post-auricular area and the upper neck. A third mass presented in the submental area and measured 3.5cm. (See Fig. 2) Eosinophilia of 51% was noted in the peripheral blood. partial excision of the left upper neck lesion and complete excision of the submental mass were performed on june 6, 1986. post-operatively she was placed on 20 mg. of prednisolone daily, but when the mass re-grew after two months she was referred to Radiation Therapy for a 2500 rad course of treatment. A barely palpable thickening remains.

  • PDF

A Study on the Dietary Quality Assessment among the Elderly in Jeonju Area (전주지역 노인의 식사의 질 평가에 관한 연구)

  • 김인숙;유현희;서은숙;서은아;이형자
    • Journal of Nutrition and Health
    • /
    • v.35 no.3
    • /
    • pp.352-367
    • /
    • 2002
  • In order to assess the quality of dietary intake among the elderly, a survey was conducted during Jucy-August, 1999, of 230 subjects who were 65 years or older and who were living in Jeonju City. Results of the analysis of the data are as follows : Regarding Dietery Variety Score (DVS), the average number of food items consumed per person was significantly higher for males (19.6) than for females (17.7). The intake of plant food was higher than animal food for both sexes the proportion of plant versus animal foods consumed by fresh weight was 85 : 15 for males and 89 : 11 for females. Diet Diversity Score (DDS) is determined by how many from five food groups (cereal, meat, dairy, vegetable and fruit) consumed per day while Korean Diet Diversity Score (KDDS) is determined by how many from five different food groups (cereal, meat, vegetable, dairy and oil) consumed per day. The subjects'average DDS and KDDS were 4.0 and 3.5 for males, and 3.7 and 3.2 for females, respectively. Overall, the distribution of DDS was lower than that of KDDS. The average Meal Balance Score (MBS : Apply the KDDS at breakfast, lunch and dinner) was 9.1 for malts and 8.1 for females. Average daily caloric intake for males and females was 1,740 kcal and 1,433 kcal, which was 84.0% and 80.9% of the RDA, respectively. Average daily protein intake for males and females, at 67 g and 49 g (100.7% and 88.3% of the RDA), respectively, was satisfactory. However, intakes of calcium and vitamin A were below 75% of the RDA (calcium : 62.7% for males and 55.3% for females ; vitamin A : 60.7% for males and 53.9% far females). The average proportional contribution of protein/fat/carbohydrate (PFC) to total calorie intake was 15.8 : 15.7 : 68.5 for males and 13.8 : 13.2 : 73.0 for females. Distribution of energy for each meal (breakfast : lunch : afternoon snack : dinner : night snack) was 29.2 : 32.4 : 5.0 : 31.2 : 2.2 among males and 30.5 : 33.5 : 4.5 : 28.6 : 2.91 among females. The Index of Nutritional Quality (INQ) was above 1 for protein, phosphorus, iron, vitamin B$_1$, niacin, and vitamin C. However, the INQ of calcium and vitamin A were below 1 among both males and females, and the INQ of vitamin B$_2$was below l among females. The Nutrient Adequacy Ratio (NAR = nutrient intake %RDA) was below 1 for all nutrients, and the NAR of vitamin A were the lowest among 9 nutrients (protein, calcium, phosphorus, iron, vitamin A, vitamin B$_1$, vitamin B$_2$, niacin, vitamin C) for both males and females, with values of 0.52 and 0.42, respectively. The second and third lowest NAR values were for calcium(males: 0.68: females: 0.54) and vitamin B$_2$(males: 0.77: females: 0.67). Values of Mean Adequacy Ratio (MAR = sum of 9 NARs/9) for males (0.82) were higher than for females (0.73). These results indicate that the intakes of calcium and vitamin A were severely inadequate. The results of a stepwise multiple regression analysis, where the DVS or MAR were the dependent variables and the DDS, KDDS, and MBS were independent variables, indicated that DDS is a more useful variable than KDDS in determining the quality of meals of the elderly.

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

Clinical Application of Serum CEA, SCC, Cyfra21-1, and TPA in Lung Cancer (폐암환자에서 혈청 CEA, SCC, Cyfra21-1, TPA-M 측정의 의의)

  • Lee, Jun-Ho;Kim, Kyung-Chan;Lee, Sang-Jun;Lee, Jong-Kook;Jo, Sung-Jae;Kwon, Kun-Young;Han, Sung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.785-795
    • /
    • 1997
  • Background : Tumor markers have been used in diagnosis, predicting the extent of disease, monitoring recurrence after therapy and prediction of prognosis. But the utility of markers in lung cancer has been limited by low sensitivity and specificity. TPA-M is recently developed marker using combined monoclonal antibody of Cytokeratin 8, 18, and 19. This study was conducted to evaluate the efficacy of new tumor marker, TPA-M by comparing the estabilished markers SCC, CEA, Cyfra21-1 in lung cancer. Method : An immunoradiometric assay of serum CEA, sec, Cyfra21-1, and TPA-M was performed in 49 pathologically confirmed lung cancer patients who visited Keimyung University Hospital from April 1996 to August 1996, and 29 benign lung diseases. Commercially available kits, Ab bead CEA (Eiken) to CEA, SCC RIA BEAD (DAINABOT) to SCC, CA2H (TFB) to Cyfra2H. and TPA-M (DAIICHI) to TPA-M were used for this study. Results : The mean serum values of lung cancer group and control group were $10.05{\pm}38.39{\mu}/L$, $1.59{\pm}0.94{\mu}/L$ in CEA, $3.04{\pm}5.79{\mu}/L$, $1.58{\pm}2.85{\mu}/L$ in SCC, $8.27{\pm}11.96{\mu}/L$, $1.77{\pm}2.72{\mu}/L$ in Cyfra21-1, and $132.02{\pm}209.35\;U/L$, $45.86{\pm}75.86\;U/L$ in TPA-M respectively. Serum values of Cyfra21-1 and TPA-M in lung cancer group were higher than control group (p<0.05). Using cutoff value recommended by the manufactures, that is $2.5{\mu}/L$ in CEA, $3.0{\mu}/L$ in Cyfra21-1, 70.0 U/L in TPA-M, and $2.0{\mu}/L$ in SCC, sensitivity and specificity of lung cancer were 33.3%, 78.6% in CEA, 50.0%, 89.7% in Cyfra21-1, 52.3%, 89.7% in TPA-M, 23.8%, 89.3% in SCC. Sensitivity and specificity of nonsmall cell lung cancer were 36.1%, 78.1% in CEA, 50.1%, 89.7% in Cyfra21-1, 53.1%, 89.7% in TPA-M, 33.8%, 89.3% in SCC. Sensitivity and specificity of small cell lung cancer were 25.0%, 78.5% in CEA, 50.0%, 89.6% in Cyfra21-1, 50.0%, 89.6% in TPA-M, 0%, 89.2% in SCC. Cutoff value according to ROC(Receiver operating characteristics) curve was $1.25{\mu}/L$ in CEA, $1.5{\mu}/L$ in Cyfra2-1, 35 U/L in TPA-M, $0.6{\mu}/L$ in SCC. With this cutoff value, sensitivity, specificity, accuracy and kappa index of Cyfra21-1 and TPA-M were better than CEA and SCC. SCC only was related with statistic significance to TNM stages, dividing to operable stages(TNM stage I to IIIA) and inoperable stages (IIIB and IV) (p<0.05). But no tumor markers showed any correlation with significance with tumor size(p>0.05). Conclusion : Serum TPA-M and Cyfra21-1 shows higher sensitivity and specificity than CEA and SCC in overall lung cancer and nonsmall cell lung cancer those were confirmed pathologically. SCC has higher specificity in nonsmall cell lung cancer. And the level of serum sec are signiticantly related with TNM staging.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF