• Title/Summary/Keyword: 등속성

Search Result 180, Processing Time 0.031 seconds

A Study on the Effect of Quadriceps Torque at the Isokinetic Mode in Patients with Hemiplegia and Healthy Subjects (Case-Control Study) (편마비 환자 및 정상인에 있어서 등속성모드로 측정한 대퇴사두근 근력에 관한 연구)

  • Jang, Moon-Heon;Ko, Joo-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.229-240
    • /
    • 1999
  • I examined the isokinetic knee extension mean torque in 30 patients with hemiplegia and 30 healthy subjects matched by age, sex, height, and weight at knee extension velocities of $30^{\circ},\;60^{\circ},\;90^{\circ}$, and $120^{\circ}$/sec. The purpose of this study is as follows: first, to compare isokinetic data between the involved and uninvolved side of patients and healthy subjects. secondly, to determine whether the relative decreases in knee extension mean torque at velocities greater than $30^{\circ}$/sec were different on the two sides. Mean torque of quadriceps on both sides of patients with hemiplegia was significantly less than the mean torque of muscle of healthy subjects at various speeds. Relative decreases in knee extension mean torque differed between speeds, but not between sides. Torque at speed greater than $30^{\circ}$/sec were correlated significantly with the torque at $30^{\circ}$0/sec. These finding indicated that isokinetic testing can provide objective information about quadriceps muscle performance in hemiplegia, and suggested that hemiplegia may have difficulty in moving forcefully at higher speeds than $30^{\circ}$/sec because they are weak. Therapeutic intervention, therefore, might be most beneficial when they are directed toward helping patients with hemiplegia activate their muscle weakness.

  • PDF

A Study on Isokinetic Strength Ratios of Hip joints in Above-knee Amputees (대퇴절단환자의 고관절 등속성근력비율에 관한 연구)

  • Song, Chang-Ho;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.74-82
    • /
    • 2003
  • The purpose of this study is to provide guideline of muscle strengthening exercise for preparing ambulation by presenting suitable ratio of muscle power of agonist & antagonist, and that of concentric & eccentric contraction on behalf of amputee's normal ambulation training and it's strenthening as well. 7 Subjects who have femur amputee for experimental group were able to ambulate naturally without inconvenience and 20 adult subjects of comparison group for comparison were considered to be free from disturbance of ambulation. The method of study was to measure the muscle power of hip pint, was to figure out the ratio of agonist & antagonist, concentric contraction & eccentric contraction, and was to find out mean and standard deviation of each measurement. Every numerical value of comparison was tested by Mann-whitney and comparison group's comparison between left & right value was done with t-test. Results are as followings : 1) Extension force was stronger than flexor force and had no remarkable difference(p<0.05) 2) For normal adults, adduction farce was stronger than abduction force and for amputees, abduction force was stronger while adduction force was the same as the normal without showing remarkable difference(p<0.05) According the result above, I make an assumption that maintaining a proper ratio of muscle power on strengthening exercise for amputee's ambulation training & rehabilitation and finally bring out an improvement of transfer and ambulation.

  • PDF

The Prediction of Hydrodynamic Forces Acting on Ship Hull Undergoing Lateral Berthing Maneuver Using CFD (CFD을 이용한 선박 접이안시 유체력 추정에 관한 연구)

  • 이윤석;정겸광행;공길영;김순값;이충로
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.132-138
    • /
    • 2003
  • In order to evaluate properly ship motion relating to the berthing maneuver, the hydrodynamic forces acting on ship hull in berthing maneuver need to be estimated rightly. CFD has been employed for time-domain simulation of transient flow induced by Wigley model moving laterally from rest in shallow water. The numerical solutions successfully captured not only the characteristics of the transitional hydrodynamic forces but also some interesting features of the flow field around a berthing ship according to the water depth. In this paper, the consideration is carried out on the approximate formula based on the CFD results, which can estimate hydrodynamic forces especially lateral drag coefficient starting from the rest to the uniform movement.

  • PDF

Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique (CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석)

  • Jeong, Jongsik;Lee, Seungjae;Lee, Jaebok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

Effect of 10 Weeks Smart Machine Circulation Exercise on Body Composition, Lung Function, Blood Lipids and Insulin Resistance in Obesity Middle-aged Women (10주간 스마트머신 순환운동이 비만 중년여성의 체조성, 폐기능, 혈중지질 및 인슐린 저항성에 미치는 영향)

  • Kim, Min-Chan;Ha, Soo-Min;Koh, Su-Han;Kim, Jong-Won;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.951-962
    • /
    • 2021
  • The purpose of this study was to analyze the effects of smart machine circulation exercise on body composition, lung function, blood lipid and insulin resistance in obesity middle-aged women among 40-60 years by dividing them into a smart machine circulation exercise group(n=8), and control group(n=6). The smart machine circulation exercise program included 55-minutes sessions thrice each week at the following intensities: The strength of aerobic exercise is applied to smart machines by linking the smart machine with the POLAR T31; the 1-4 week is 40-50%HRR, 5-8 week is 50-60%HRR, and 9-10 week is 60-70%HRR. The strength of the resistance exercise was tested using a smart machine based on the constant velocity motion, and then, using the 1-RM data value, applied 40% 1-RM for 1-4 weeks, 60% 1-RM for 5-8 weeks, and 80% 1-RM for 9-10 week. As a results, body composition indicated that weight, BMI, %BF, WHR had a significant interaction effect. Lung function indicated that FVC levels significantly changes in the exercise group and the between groups difference in changes at 10week was significant. Also, FVC and FEV1 significantly showed interaction effect. TC, TG and HDL-C levels significantly changes in smart machine circulation exercise group and the between-group difference in changes after 10 weeks was significant. TC, TG and HDL-C significantly showed interaction effect. Insulin resistance demonstrated that Insulin, Glucose and HOMA-IR levels significantly showed difference over 10 weeks between group. Therefore, the 10 weeks smart machine circulation exercise positively effects on the body composition, lung function, blood lipids, and insulin resistance in obesity middle-aged women and this smart machine circulation exercise can improve their obesity and prevent obesity.

Development of Lane Changing Model with regard to Safety Distance of Vehicles (차량간 안전거리를 고려한 차로변경 모형개발)

  • Choe, Ji-Eun;Ryu, Byeong-Yong;Bae, Sang-Hun;Gang, Seung-Pil
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.6
    • /
    • pp.109-118
    • /
    • 2009
  • The conventional lane changing model has been developed without acceleration or deceleration of vehicles at target lane. Thus, existing lane changing models have limitation to apply in real world. In this paper, lane changing model considered acceleration or deceleration, and calculated the safety distance between subject vehicle and adjacent vehicles for lane changing as well. Simulation was conducted to verify the validity and the efficiency of the developed lane changing model in this paper. Several scenarios were carefully examined by safety distance between subject vehicle and adjacent vehicles. In the result, it was verified that if gap between subject vehicle and adjacent vehicles is larger than safety distance, lane changing behavior between subject vehicle and adjacent vehicles avoids collision. The suggested lane changing model may be applied at the future driver assistance system and advanced safety vehicle.

Facilitation of Quadriceps Activation Following a Concentric Knee Flexion During Reciprocal Knee Movement: The Influence of Muscle Preloading (교차적 슬관절 굴곡-신전 시 슬관절 굴곡근의 구심성 수축에 의한 선행부하가 대퇴사두근의 활성화에 미치는 영향)

  • Jeon, Hye-Seon;Trimble, Mark H.;Brunt, Denis
    • Physical Therapy Korea
    • /
    • v.10 no.4
    • /
    • pp.1-15
    • /
    • 2003
  • 본 연구는 슬관전 신전 직전에 수행된 선행 슬관절 굴곡이 슬관절 신전근의 최대 근력발생 및 근육 활성도(activation)에 미치는 영향을 알아보기 위하여 실시되었다. 16명의 정상인이 Cybex II 등속운동기구에서 3가지 다른 운동 속도($100^{\circ}/s$, $200^{\circ}/s$, $300^{\circ}/s$)와 2가지 다른 근육 활성 조건(선행부하가 없는 조건과 선행부하 조건)에서 슬관절의 최대 신전을 수행하였다. 연구대상자들에게 선행부하 없는 조건에서는 $90^{\circ}$ 슬관절 굴곡 상태에서 $0^{\circ}$까지 최대 신전을 수행하도록 하였고, 선행부하 조건에서는 구심성 슬와부 근육의 구심성 수축으로 $0^{\circ}$에서 $110^{\circ}$까지 굴곡한 후, 다시 $0^{\circ}$까지 최대 신전을 하도록 요구하였다. 종속변인으로는 내측광근과 외측광근의 최대 근전도와 최대 신전근력을 측정하였다. 실험 결과 최대 근전도와 최대 근력 모두 선행부하 조건에서 높게 나타났으며, 운동 속도가 증가함에 따라 최대 근력은 감소하는 전형적인 최대 근력-운동속도 상관법칙이 본 실험에서도 나타났다. 또한 운동속도와 전환속도 간의 간섭이 없는 것으로 나타나, 슬관절 신전근에 선행부하(preloading)를 가하는 것이 최대 근력-운동속도 상관법칙(force-velocity relation)에 영향을 미치지 못하는 것으로 해석되었다. 선행부하로 인해 증가된 최대 근력 및 근 활성도의 증가는 주로 신경촉진에 의한 것으로 해석된다.

  • PDF

Effects of Shoulder Muscle Strength on Terminal Range by Humeral Head Retroversion (상완골 후경각이 가동역에 따른 견관절 근력에 미치는 영향)

  • Park, Si-Young;Lee, Dong-Jun
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.549-554
    • /
    • 2010
  • Increased external rotation and decreased internal rotation have been noted to occur progressively in the throwing shoulders of baseball pitchers. The purpose of this study was to provide descriptive data for terminal range eccentric antagonist/concentric agonist shoulder muscle strength in collegiate baseball pitchers with humeral head retroversion diagnosed through MRI. The dominant and non-dominant shoulders of 9 asymptomatic baseball pitchers were tested through a range of 20 degrees of external rotation to 90 degrees of internal rotation using the Biodex system 3 isokinetic dynamometer at speeds of $90^{\circ}/s$ and $180^{\circ}/s$. Differences between the dominant and non-dominant shoulders were assessed using the paired samples t-test. Total range of motion, measured at $90^{\circ}$ of glenohumeral abduction, was $180.1^{\circ}$ for dominant shoulders and $183.7^{\circ}$ for non-dominant shoulders. Humeral head retroversion measured $47.6{\pm}6.1^{\circ}$ in dominant and $37.8{\pm}5.3^{\circ}$ in non-dominant extremities. The mean internal rotator concentric contraction (IR-Con) showed a significant difference compared to $31.5{\pm}5.1$ (Nm) in dominant and $38.7{\pm}5.2$ (Nm) in non-dominant shoulders at $180^{\circ}/s$ (p<0.05). The mean external rotator eccentric contraction (ER-Ecc) showed a significant difference compared to $20.3{\pm}4.7$ (Nm) in dominant and $25.1{\pm}3.7$ (Nm) in non-dominant shoulders at $90^{\circ}/s$ (p<0.05). There is a pattern of increased external rotation and decreased internal rotation in the dominant extremity that significantly correlates with an increase in humeral retroversion.

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

The Effects of Stimulus Velocity and Skill Levels on Anticipation Timing Performance of Passing (자극의 가속 및 감속 조건에 따른 숙련도별 농구 패스의 예측 타이밍 수행의 차이)

  • Hong, Seung-Bun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.4
    • /
    • pp.249-255
    • /
    • 2015
  • The study was to investigate the effects of stimulus velocity and passer's skill level on anticipation timing performance. Fourteen subjects(seven novices and seven experts) were required to make a total 12 passes in coincidence with an experimentally manipulated moving light signal in randomly presented three different conditions(4m/s, $3m/s{\rightarrow}5m/s$, $5m/s{\rightarrow}3m/s$). Results of analyses showed that absolute error(AE) and constant error(CE) were greater in constant acceleration of the moving stimulus. In addition, experts were more accuracy and consistency than novices on absolute, constant and variable error(VE). These findings indicated that stimulus velocity served as the major determination of anticipation timing performance of passing.