• Title/Summary/Keyword: 등가평판

Search Result 89, Processing Time 0.023 seconds

An Experimental Study of Fuselage Drag and Stability Characteristics of a Helicopter Configuration (회전익 항공기 형상의 기체공력 특성에 관한 실험적 연구)

  • Oh, Se-Yoon;Park, Keum-Yong;Lee, Jong-Geon;Ahn, Seung-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.9-15
    • /
    • 2005
  • This paper describes the test carried out on an experimental study of fuselage drag and stability characteristics of a helicopter configuration and the test techniques developed for the testing and the lessons learned in the Agency for Defense Development Low Speed Wind Tunnel(ADD-LSWT). The main objective of this test is to determine the drag and stability characteristics of helicopter configurations according to the various configuration changes. The fuselage model with a highly modular structure is a representation of 1:8 scale of the external contour of the conceptual design helicopter configuration with rotating main rotor hub including blade stubs capable of rotating up to 500 rpm. The test results are compared with the available similar data and fair to good agreement is obtained.

A Study on a Symmetric QMSA (대칭형 QMSA에 관한 연구)

  • Go, Yeong-Hyeok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.5
    • /
    • pp.33-41
    • /
    • 2000
  • In this paper, a symmetric QMSA(Quarter-wavelength Microstrip Antenna) loading a capacitor to spread the electric flux lines is proposed. It was found that the bandwidth of this symmetric QMSA is broader than that of the asymmetric QMSA having a right-side Parallel plate only to load a capacitor. It was also found that this antenna could receive both vertically and horizontally polarized waves at 2.13GHz, and would be useful as a small antenna for wireless telephones and for indoor communication. A transmission line circuit model of this antenna was obtained and used to compute the resonant frequency and the return loss of the antenna accurately.

  • PDF

Design of a Small Loop Microstrip Antenna to load Capacitors (용량을 장하한 미소 루프 마이크로스트립 안테나 설계)

  • Park Seong-Il;Ko Young-Hyuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.637-640
    • /
    • 2006
  • In this paper, a microstrip antenna with a small loop consisting of the left and right parallel plate to load capacitor is proposed. It is obtained the improved small size than the antenna of the transformed Uh and the antenna of the left and right parallel plate to load capacitor on QMSA. Equivalent circuit of transmission line model is designed to find more accurate resonant frequency. Also, the designed and fabricated antenna can receive both vertically and horizontally polarized waves to operating frequency of 1.5GHz. Therefore proposed antenna is available as a small antenna for wireless communication and will be quite useful for indoor communication

  • PDF

Characteristics of Sound Insulation in Sandwich Plates with Orthotropic Skin Plate (이방성판을 사용한 샌드위치판의 차음특성)

  • Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Jae-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.853-856
    • /
    • 2004
  • This study presents a prediction method for sound insulation of sandwich plate which consists of orthotropic plates as skin and mineral wool as core. Prediction by classic theory, which considers orthotropic effects, requires considerably complex and cumbersome process and moreover many assumption. However, experimental results of the sandwich plate with orthotropic plates as skin show that the orthotropic effects are disappeared or fade out. Hence, predictions by using sandwich model are conducted by a simple modelling that substitutes an orthotropic plate into an equivalent flat plate. Comparative results show that sandwich model gives a good agreements with theoretical prediction.

  • PDF

Comparison between Numerical Results of 1D Beam and 2D Plane Stress Finite Element Analyses Considering Aspect Ratio of Cantilever Beams (캔틸레버보의 형상비에 따른 1차원 보와 2차원 평면응력 유한요소해석 결과의 비교)

  • Kang, Yoo-Jin;Sim, Ji-Soo;Cho, Hae-Sung;Shin, Sang-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.459-465
    • /
    • 2015
  • There exist different kinds of aircrafts, such as conventional airplane, rotorcraft, fighter, and unmanned aerial vehicle. Their shape and feature are dependent upon their own assigned mission. One of the fundamental analyses performed during the aircraft design is the structural analysis. It becomes more complicated and requires severe computations because of the recent complex trends in aircraft structure. In order for efficiency in the structural analysis, a simplified approach, such as equivalent beam or plate model, is preferred. However, it is not clear which analysis will be appropriate to analyze the realistic configuration, such as an aircraft wing, i.e., between an equivalent beam and plate analysis. It is necessary to assess the limitation for both the one-dimensional beam analysis and the two-dimensional plate theory. Thus, in this paper, the static structural analysis results obtained by EDISON solvers were compared with the three-dimensional results obtained from MSC NASTRAN. Before that, EDISON program was verified by comparing the results with those from MSC NASTRAN program and other analytic solutions.

Behavior of Bearing Capacity for Shallow Foundation on a Sand overlying Clay Depending on Bearing Capacity Ratio (점토층 위 모래지반의 지지력비에 따른 얕은 기초의 지지력 거동)

  • Jung, Min Hyung;Shin, Hyo Hee;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.198-208
    • /
    • 2011
  • When a structure which has relatively low load constructs on soft clay, the bearing capacity of the ground will be improved by sand overlying clay. In this condition, verifying the bearing capacity is difficult from the P.B.T etcetera in the in-situ. So, it is needed to estimate precise bearing capacity in the design process. In this study, 2-dimensional chamber tests and FEM analyses are conducted to evaluate behavior of bearing capacity for shallow foundations on a sand overlying clay. Because depth ratio H/B and bearing capacity ratio $q_c/q_s$ are selected as main factors, height of a sand, undrained shear strength of a clay and width of a loading are designated as variables. Results from chamber tests are very similar with those of FEM analyses. And it shows that punching shear mechanism is more suitable than the equation of Okamura et al.(1998). To make continual application of load spread mechanism, the equivalent load spread angle is proposed for H/B and $q_c/q_s$. Also, the linear regression equation of critical depth ratio Hf is suggested for $q_c/q_s$.

A Study of Dosimetric Characteristics of a Diamond Detector for Small Field Photon Beams (광자선 소조사면에 대한 다이아몬드 검출기의 선량특성에 관한 연구)

  • Loh, John-K.;Park, Sung-Y.;Shin, Dong-O.;Kwon, Soo-I.;Lee, Kil-D.;Kim, Woo-C.;Cho, Young-K.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.195-203
    • /
    • 1999
  • It is difficult to determine dosimetric characteristics for small field photon beams since such small fields do not achieve complete lateral electronic equilibrium and have steep dose gradients. Dosimetric characteristics of small field 4, 6, and 10 MeV photon beams have been measured in water with a diamond detector and compared to measurements using small volume cylindrical and plane parallel ionization chambers. Percent depth dose (PDD) and beam profiles for 6 and 10 MeV photon beams were measured with diamond detector and cylindrical ion chamber for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. Total scatter factors($S_{c,p}$) for 4, 6, and 10 MeV photon beams were measured with diamond detector, cylindrical and plane parallel ion chambers for small fields ranging from $1{\times}1\;to\;4{\times}4cm^2$. The $S_{c,p}$ factors obtained with three detectors for 4, 6, and 10 MeV photon beams agreed well ($\pm1.2%$) for field sizes greater than $2{\times}2,\;2.5{\times}2.5,\;and\;3{\times}3\;cm^2$, respectively. For smaller field sizes, the cylindrical and plane parallel ionization chambers measure a smaller $S_{c,p}$ factor, as a result of the steep dose gradients across their sensitive volumes. The PDD values obtained with diamond detector and cylindrical ionization chamber for 6 and 10MeV photon beams agreed well ($\pm1.5%$) for field sizes greater than $4{\times}4\;cm^2$. For smaller field sizes, diamond detector produced a depth-dose curve which had a significantly shallower falloff than that obtained from the measurements of relative depth-dose with a cylindrical ionization chamber. For the measurements of beam profiles, a distortion in terms of broadened penumbra was observed with a cylindrical ionization chamber since diamond detector exhibited higher spatial resolution. The diamond detector with small sensitive volume, near water equivalent, and high spatial resolution is suitable detector compared to ionization chambers for the measurements of small field photon beams.

  • PDF

A Method of Contact Pressure Analysis between Half-space and Plate (탄성지반과 판의 접촉압력해석에 관한 연구)

  • Cho, Hyun Yung;Cheung, Jin Hwan;Kim, Seong Do;Han, Choong Mok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 1992
  • A method analizing contact pressure between plate and elastic half space is presented by using F.E.M. With the method, the pressure intensities at surface nodes of half space cae be directly calculated by using flexibility matrix of half space. The method is originally presented by Y.K. Cheung et al.(3) Insted of Y.K. Cheung's method, which use a conception of equi-contact pressure area around each surface nodes of half space in the noded rectanqular element area. We use the equi-contact pressure area around the Gaussian integration points of half space surface in the noded isoparametric element area. Numarical examples are presented and compared with other's studies.

  • PDF

Investigation of a Thermal Stress for the Unit Cell of a Solid Oxide Fuel Cell (고체산화물 연료전지 단위셀의 열응력에 관한 연구)

  • Kim, Young-Jin;Park, Sang-Kyun;Roh, Gill-Tae;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.414-420
    • /
    • 2011
  • Thermal stress analysis of a planar anode-supported SOFC considering electrochemical reactions has been performed under operating conditions where average current density varies from 0 to 2000 $A/m^2$. For the case of the 2000 $A/m^2$ operating condition, Structural stress analysis based on the temperature distributions obtained from the CFD analysis of the unit cell has also been done. From this one way Fluid-Structure Interaction(FSI) analysis, Maximum Von-Mises stress under negligible temperature gradient fields occurs when cell components are perfectly bonded. The maximum stress of the electrolyte, cathode and anode in a unit cell SOFC is 262.58MPa, 28.55MPa and 15.1MPa respectively. The maximum thermal stress is critically dependent on static friction coefficient.

Calculating Method of FRF with Sub-structure Mode Synthesis Method (부분구조 모드합성법에 의한 주파수응답함수 산출법)

  • Oh, Chang-Guen;Park, Kyung-Il;Park, Sok-Chu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.393-398
    • /
    • 2015
  • A very important part in vibration analysis is to calculate the frequency response function (FRF). In general, a large sized or/and complicated structure has many thousands to millions of degrees. Therefore, the FRF cannot be calculated by the traditional analysis method using an inverse matrix. This paper presents a new FRF calculation method of a superstructure by synthesizing sub-structure modes, of which the DOF can be deduced by partitioning into some sub-structures. To confirm its analysis results, the method was applied to an assembled plate ($B300{\times}L900{\times}t5mm$) with three diagonal sub-plates($B300{\times}L300{\times}t5mm$) in series and compared with the measured data. The test results have were comparable those of the calculated ones with an error less than 5%.