• Title/Summary/Keyword: 동작소방서

Search Result 8, Processing Time 0.02 seconds

현상설계경기

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.9 s.341
    • /
    • pp.116-126
    • /
    • 1997
  • PDF

계획작품

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.11 s.343
    • /
    • pp.96-99
    • /
    • 1997
  • PDF

Computer Controller Design and Movement of Hovercraft Driving Apparatus (호버크래프트 추진장치의 컴퓨터 제어기 설계와 동작)

  • Baek, Dong-Hyun;Song, Ho-Bin;Cho, Moon-Tack
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.32-38
    • /
    • 2011
  • Amphibious possible, and good fuel economy, so as leisure and transport has increased the use of hovercraft. Fire started in Korea, the prevalence is increasing in demand as the trend has been increasing steadily. In this paper, the hovercraft's forward and backward direction can be controlled in order to free the reverse bucket control system was developed. Control due to development by promoting the flow of air and turn right, turn left and easy to reverse the life-saving and stable at high speed, etc. has made possible the operation of hovercraft. The controller for the stability and fast response Fuzzy-PID method was used. To prove the validity of the proposed controller in Matlab simulation and the actual delivery at the firehouse, built into a model for the demonstration test was performed.

Changes in The Amount of Air Respirator Consumed by Field Fire-fighting Activities (현장 소방활동에 따른 공기호흡기 소모량의 변화)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.93-98
    • /
    • 2019
  • The purpose of this study was to identify and analyze the rate of change of air respirator consumption based on field fire fighting activities, The results of the experiment are as follows. The mean air consumption of the Five subjects was $15.56{\ell}/min$ when standing still, $32.43{\ell}/min$ when walking with normal pace, $43.07{\ell}/min$ when the fire hoses was expanded and arranged, $55.28{\ell}/min$ when climbing stairs, The situation of running up the stairs and hitting the hammer continuously increases to $127.14{\ell}/min$, which means that the consumption of air increases according to the energy consumption. Despite being the oldest, Experimental subject A was $13.23{\ell}/min$ when standing still, $29.33{\ell}/min$ when walking normally, and $41.08{\ell}/min$ when the fire hose was deployed and arranged. This is a result of familiarity with deep and slow breathing methods. The average respiratory use rate of subjects D was $63.58{\ell}/min$. The reason for this is that obesity seems to increase the air consumption, and it is considered that the physical strength is exhausted by the action of the hammer, which has a greater influence on the increase of air consumption. The subject E had significantly lower air respiratory use rate of $49.90{\ell}/min$. The reason for this is that the age of E is the youngest among the subjects, and it is presumed that it possesses strong physical strength.

Development of glass bulb for sprinkler head system (스프링클러용 유리발브의 개발)

  • Kim, Byung-Cheol;Joung, Hoon-Choul;Seo, Yo-Won;Myung, Young-Sup
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.144-147
    • /
    • 2008
  • A glass bulb is the most reliable and simplest device for a fire sprinkler head system. We had developed an accurate glass bulb. The glass bulb is composed with a glass ampoule, liquid filled within the ampoule and an air bubble in the liquid. The first step of the development was to establish a stable mass production system for uniform glass ampoule. The second step is to optimize the composition of the liquid and the size of the bubble. It was also a difficult problem to devise manufacturing process to form uniform bubble size. The final step for the development is to control the mechanics for glass breaking by surface treatment for the glass bulb.

  • PDF

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

The effects of muscle activity of ambulance workers carrying a patient on a stretcher with or without helmets (구급대원의 헬멧 무게에 따른 들것 들고 내릴때 근활성도에 미치는 융합 요인분석)

  • Shin, Dong-Min;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.371-380
    • /
    • 2019
  • Electromygram was measured in three different cases; not wearing of a helmet, wearing of a 920g helmet, and wearing of a 1310g helmet, and it was revealed that there was a high level of muscle activities on the opposite side (sternocleidomastoid muscle) while the head and the neck were moving right and left and muscle activities of the curve and of the hyperextension were found to be not significant. Especially, the presence of a helmet seemed to cause a difference in a level of muscle activities on the deltoid and erector spine muscles while lifting or lowering with a weight placed on the deniz backboard. Therefore, it would be possible to assume that this newly developed smart helmet would not affect muscles around the necks of paramedics if they do not move their necks and heads right and left while lowering or lifting a patient using the deniz backboard. In addition, in case of the deltoid and erector spine muscles, it is shown that an increase in the degree of movement could lead to an increase in the level of muscle activities on the muscles controlling of the corresponding action, which are waist and back muscles. Despite it, it would be possible to prevent possible injuries and/or muscular and skeletal diseases around the lumbar by fully complying with a basic rule of straightening of the waist while making a power-lifting motion.

Effect of chest compressions on the quality of back pain prevention and chest compressions by applying body stabilization Convergence movement (체간안정화 융합운동을 접목한 가슴압박이 요통예방과 가슴압박 품질에 미치는 영향)

  • Hong, Eun-Jeong;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.5
    • /
    • pp.85-94
    • /
    • 2019
  • This study was aimed to identify a study on the effect of chest compressions combined with abdominal drawing-in technique on prevention of back pain and chest compression quality. We tested motion analysis, electromyography, and chest compression quality of 15 paramedics. Data were normalized to SPSS 21.0 (Kolmogorov-Smirnov and Shapiro-Wilk test). The paired t-test was used for the pre- and post-test chest compressions, the one-way ANOVA was used for the analysis of the measurement point-in-time differences, and LSD was used for the post-test. The results of the study showed significant difference in muscle activity and chest compression success rate when the chest pressure was applied with abdomen drawing-in. Therefore, it is necessary to study cardiopulmonary resuscitation education which can increase the chest compression success rate while preventing the back pain of the paramedics in the future.