• 제목/요약/키워드: 다공충격판

검색결과 6건 처리시간 0.022초

급수가열기 충격판 설계변경에 따른 동체감육 완화에 관한 유동해석 연구 (A Study on the Fluid Mixing Analysis for the Shell Wall Thinning Mitigation by Design Modification of a Feedwater Heater Impingement Baffle)

  • 김경훈;황경모;진태은
    • 한국시뮬레이션학회논문지
    • /
    • 제14권2호
    • /
    • pp.35-43
    • /
    • 2005
  • Feedwater heaters of many nuclear power plants have recently experienced wall thinning damage, which will increase as operating time progresses. As it is judged that the wall thinning damages have generated due to local fluid behavior around the impingement baffle installed in downstream of the high pressure turbine extraction steam line to avoid colliding directly with the tubes, numerical analyses using PHOENICS code were performed for two models with original clogged impingement baffle and modified multi-hole impingement baffle. To identify the relation between wall thinning and fluid behavior, the local velocity components in x-, y-, and z-directions based on the numerical analysis for the model with the clogged impingement baffle were compared with the wall thickness data by ultrasonic test. From the comparison of the numerical analysis results and the wall thickness data, the local velocity component only in the y-direction, and not in the x- and z-direction, was analogous to the wall thinning configuration. From the result of the numerical analysis for the modified impingement baffle to mitigate the shell wall thinning, it was identified that the shell wall thinning may be controlled by the reduction of the local velocity in the y-direction.

  • PDF

다공탄성체 척추운동분절 유한요소 모델에서 추간판의 변성이 충격 거동에 미치는 영향 해석 (Analysis of Impact Response in a Poroelastic Spinal Motion Segment FE Model according to the Disc Degeneration)

  • 김영은;박덕용
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.188-193
    • /
    • 2003
  • To predict changes in biomechanical parameters such as intradiscal pressure, and the shock absorbing mechanism in the spinal motion segment under different impact duration/loading rates, a three dimensional L3/L4 motion segment finite element model was modified to incorporate the poroelastic properties of the motion segment. The results were analyzed under variable impact duration for normal and degenerated discs. For short impact duration and a given maximum compressive force, relatively high cancellous pore pressure was generated as compared with a case of long impact duration, although the amount of impulse was increased. In contrast relatively constant pore pressure was generated in the nucleus. Disc degeneration increased pore pressure in the disc and decreased pore pressure in the cancellous core, which is more vulnerable to compressive fracture compared with intact case.

다공판이 내장된 반사형 소음기의 소음저감 성능 (Noise Reduction Performance of a Reactive type Silencer with Perforated Panels)

  • 이선기;이영철;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

슬롯 형상이 경사충격파 간섭유동의 피동제어에 미치는 영향에 관한 연구 (Effects of Slot Configurations on the Passive Control of Oblique-Shock-Interaction Flows)

  • 장성하;이열
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.18-24
    • /
    • 2006
  • 슬롯과 다공판을 이용한 충격파와 난류 경계층 간섭유동의 피동제어에 관한 연구가 수행되었다. 슬롯의 다양한 형상 변화가 간섭유동에 미치는 영향이 관찰되었으며, 이를 위하여 간섭유동 후방에서 피토/벽압력 분포 및 쉴리렌, 유맥선, 오일막 간섭 줄무늬 형상과 같은 유동가시화 결과 등이 얻어졌다. 유동방향의 슬롯의 경우 간섭유동 후방에서 제어되지 않은 경우와 비교하여 보다 높은 피토압력이 국소적으로 관찰되었으나, 폭방향 슬롯제어는 전체적으로 제어되지 않은 경우에 비하여 피토압력 크기에서 큰 장점을 보이지 않았다.

충격파 감금법을 이용한 고압배기가스 유동의 제어 (Control of High-Pressure Exhaust Gas Flows Using Shock-Wave Confinement)

  • 김희동;김태호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1998년도 제10회 학술강연회논문집
    • /
    • pp.19-19
    • /
    • 1998
  • 최근 화학, 연소, 동력, 제철 등의 각종 플랜트에서 조업압력이 고압화되어 가고 있으며, 이에 수반하여 배관계를 통하는 고압가스 유동에 관한 연구가 활발하게 진행되고 있다. 배관계를 통하는 고압가스의 유동에 있어서 유량의 적절한 제어, 유동에 의하여 야기되는 배관계의 소음·진동, 그리고 배기가스의 적절한 처리법 등은 공학적으로 매우 중요한 문제로 알려져 왔다. 일반적으로 정상운전을 하는 플랜트에서 고압 배기가스의 문제는 배기가스 Expander에 의하여 에너지를 회수하는 방법이 생각될 수 있으나, 실제 공업현장에서는 배기가스를 안전하고, 또 소음·진동을 발생시키지 않도록 적절하게 처리하는 것이 매우 중요한 기술적 과제로 남아 있다. 일반적으로 배기가스의 압력이 임계압력(critical pressure) 이상으로 되는 경우(실제 대부분의 플랜트에서 배기가스의 압력은 임계압력보다 매우 높다), 배관계 내부에서 충격파(shock-wave)가 발생하여 난류와동 혹은 난류경계층과 간섭하게 됨으로써 강력한 공기역학적 소음이나 진동을 발생시키게 된다. 이와 같은 소음·진동에 대한 대책으로는 현재 가스배출부에 감압밸브를 직렬로 설치하거나, 유로에 다공판(porous plates)들을 삽입하여 감압과정을 공간적으로 분산시킴으로써, 충격파가 발생하지 않도록 하는 방법을 주로 채택하고 있다. 그러나 이러한 방법을 적용하는 경우 배기가스 유동에 대한 유량의 제어기능이 저하되는 문제가 발생한다.

  • PDF

유동층 공정변수의 고체입자 마모에 미치는 영향 (The Effect of Fluidized-Bed Variables on Attrition of Solid Particles)

  • 문영섭;이창근;손재익;류청걸;최정후
    • 공업화학
    • /
    • 제16권5호
    • /
    • pp.603-608
    • /
    • 2005
  • 본 연구는 zinc titanate를 탈황제로 사용하는 유동층 탈황공정에서 고체 입자 마모특성을 고찰하는 것을 목표로 내경 0.035 m, 높이 1.34 m의 기체유동층 실험장치에서 수행되었다. 다공판 분배기에서 고속 분사 제트와 유동층 내부의 기포요동이 입자마모의 주요 원인으로 사료되었다. 탈황제의 마모속도가 작아서 회분식 측정결과가 연속식 유동층에 근사하게 적용될 수 있는 조건에서 수행되었다. 탈황공정에서 주요 변수인 기체유속, 온도, 압력, 층물질량의 변화에 따른 AI(attrition index)와 CAI(corrected attrition index)를 측정하였다. AI(5), CAI(5)는 층 무게가 증가함에 따라 감소하였다. 입자는 일정기간 충격에 의한 피로현상이 있은 후 마모되는 것으로 판단되었다. AI와 CAI는 기체속도, 상대습도, 압력이 증가함에 따라, 온도가 감소함에 따라 증가하였다. 입자마모는 주로 제트에 의하여 일어났으며 절단(fragmentation)보다 마쇄(abrasion)에 의하여 더 많은 미분입자가 발생하였다.